materials..(but a customized window material worked fine..). Does anyone have experience run into this error before? Please let me know!
"10. Runtime error (KeyNotFoundException): KeyError
11. Traceback: line 2145, in main, "<string>" line 2367, in script line 1097, in EPMaterialStr, "<string>" "
I'm also attaching my Rhino and GH file. Any help would be much appreciated.
Thanks!
…
s the "Surface Populating" definition: I manage to populate my geometry over the surface, but after I bake it, I have to delete the boxes that define my components limits as well! Is there any way of populating and baking only the chosen component, without having to delete the boxes afterwards?
Secondly:
Basically: I am trying to cover a surface with two types of components [ an open one and a closed one] , which will be proliferated over my tubular surface according to the main sunlight direction.
1. I introduce the surface component.
2. I use "Divide Interval2" in order to have division into U and V.
3. i generate the target boxes [ "surfaceBox"] .
4. I use "Isotrim" ( same intervals) and "BRepArea" to find centroid of each area.
5. My "Curve" component introduces sun angle, with its "End Points".
6. I use "Vector 2Pt" to specify sun-light direction.
7. I want to measure the angle between sun-light and the surface normals, at the position of each component; after generating the centre points, I need the normals of each centre point to get the surface's points' UV, and "Evaluate" the srf at points.
8."Angle" and "Vector" components: I use them in order to evaluate the angle between the sun direction and the srf.
9. I convert this angle to degree by using a "Function" [ to see if the angle is bigger from the max.angle or not...]
10. Function "x,y" gives me boolean data.
11. Data become "Dispatch"ed...
12. Two "Morph" components , each one linked to one part of the "Dispatch" data, generate "closed" and "open" components over the srf.
The result should have been different types of components, based on the surface's curvature, diraction and sun-light direction...
I do not understand where the mistake is in this definition...
Thx in advance1
Spyros K.…
ells new products like the Firefly Interactive Prototyping Shield which mounts on top of your Arduino Uno and provides access to a number of useful input (ie. sensors) and output (ie. motors) devices. It includes features like:
Three linear slide potentiometers connected to analog pins 0, 1, and 2
Two-axis joystick connected to analog pins 3 and 4
Light sensor (photocell) connected to analog pin 5
Three push buttons connected to digital pins 2, 4, and 7
Red LED connected to digital pin 13
RGB LED connected to digital pins 3, 5, and 6
Two servo connections on digital pins 8 and 9
A connection to the Easy Stepper Driver (co-designed by Sparkfun Electronics and Brian Schmalz) to control stepper motors. The direction of the motor is controlled through digital pin 10 and the number of steps through digital pin 12
High-voltage MOSFET circuit capable of driving lights, valves, DC motors, solenoids, or anything else requiring higher voltage or current. The gate of the MOSFET is connected to digital pin 11 (PWM).
Some come take a look and let us know what you think!
…
nch, xno items in one list)2 divide the list lenght value by the numer of items per branch needed3A generate a list with the series component: the step equal to the target numer of items per branch; the no of items equals the number of target branches
3B generate a list with the series component: the first number of the series equals to the number of items needed (-1 to account for the 0 index); the step size again equal to the target number of itmes per branch as 3A4 feed 3A & 3B to a domain component thus identifying the start -3A- and end -3B- of the domains by which the list will be subdivided5 use a subset component with the domains above thus creating 19 branches with lists having 5 items eachfor lists which are subdivided into branches when the target number of branches is not a multiple of the number of items contained in the list:6 identify if the target number of branches is a multiple of the list by using the modulus component fed by the list lenght -1- and the target number of branches7 identify last index in the 3B series with the item component (reversed to take the last value fed)8 add 6+7 above which dill define the start of the domain that will pick up the remanent items not accommodated in 59 add (+1) to 7 above to define the end of the domain that will pick up the the remanent items not accommodated in 510 feed 8 & 9 to a domain component11 include 10 as part of the subset in 5I'm now trying to understand the components mentioned by Michael...
sn
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
you post a screenshot of what the message coming from its readMe! output looks like?2) Close your Grasshopper and Rhino.3) Download "Revo Uninstaller Pro" from here. It is free for first 30 days, which is what we need.4) Right click on the RevoUninProSetup.exe and check if the file is blocked. If it is, unblock it.5) Run the RevoUninProSetup.exe file and install "Revo Uninstaller Pro".6) Uninstall "MapWinGIS" with "Revo Uninstaller Pro". It is important that "Revo Uninstaller Pro" deletes not only files from MapWinGIS installation folder, but also all other leftovers (as registry inputs). Here is a small tutorial on how to do that. Watch it from 6:10 till the end.7) Restart your PC8) When your Windows boots up, make sure that you are logged in as Administrator!9) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".10) Turn off your Windows Firewall.11) Then turn off your custom Firewall (in case you have another one, besides standard Windows Firewall).12) Completely turn off your Antivirus.13) Download again the MapWinGIS-only-v4.9.4.2-x64.exe.exe file from here.14) Right click on the MapWinGIS-only-v4.9.4.2-x64.exe file and see if it is blocked. If it is, unblock it.15) Right click on MapWinGIS-only-v4.9.4.2-x64.exe file and choose: "Run as"... Administrator.16) One the installation preparation steps start, choose "Full installation". Wait for the MapWinGIS installation to finish.17) Right-click on "Rhino 5" icon and then choose: "Run as administrator".18) Open the the ironpython_admin.gh file again, and again post a screenshot of the message coming from its readMe! output.19) Drop the "Gismo Gismo" component to Grasshopper canvas. Post a screenshot of the message coming out from its readMe! output.
So we will need in total three screenshots of the readMe! output messages.
Thank you once again for being patient, and sorry for the large number of steps.…
Added by djordje to Gismo at 1:52am on April 9, 2017
8.3.0 ************* IDF Context for following error/warning message: ************* Note -- lines truncated at 300 characters, if necessary... ************* 829 Construction, ************* indicated Name=PELLE001 ************* Only last 10 lines before error line shown.....
************* 832 AIR WALL2, !- - Layer 2 ************* 833 X-LAM, !- - Layer 3 ************* 834 POLYSTYRENE2, !- - Layer 4 ************* 835 PANNELLO VIP, !- - Layer 5 ************* 836 POLYSTYRENE2, !- - Layer 6 ************* 837 X-LAM, !- - Layer 7 ************* 838 LANA DI ROCCIAS, !- - Layer 8 ************* 839 VANO IMPIANTI, !- - Layer 9 ************* 840 LANA DI ROCCIAS, !- - Layer 10 ************* 841 LASTRA IN GESSOFIBRA, !- - Layer 11 ** Severe ** IP: IDF line~841 Error detected for Object=CONSTRUCTION ** ~~~ ** Maximum arguments reached for this object, trying to process ->LASTRA IN GESSOFIBRA<- ************* IDF Context for following error/warning message: ************* Note -- lines truncated at 300 characters, if necessary... ************* 985 Construction, ************* indicated Name=ROOF001 ************* Only last 10 lines before error line shown..... ************* 988 TRAVETTI, !- - Layer 2 ************* 989 TAVOLATO, !- - Layer 3 ************* 990 POLYSTYRENE2, !- - Layer 4 ************* 991 PANNELLO VIP, !- - Layer 5 ************* 992 POLYSTYRENE2, !- - Layer 6 ************* 993 X-LAM, !- - Layer 7 ************* 994 LANA DI ROCCIAS, !- - Layer 8 ************* 995 VANO IMPIANTI, !- - Layer 9 ************* 996 LANA DI ROCCIAS, !- - Layer 10 ************* 997 LASTRA IN GESSOFIBRA, !- - Layer 11 ** Severe ** IP: IDF line~997 Error detected for Object=CONSTRUCTION ** ~~~ ** Maximum arguments reached for this object, trying to process ->LASTRA IN GESSOFIBRA<- ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details. ** Severe ** IP: Possible incorrect IDD File ** ~~~ ** IDD Version:"IDD_Version 8.3.0" ** ~~~ ** Version in IDF="8.3" not the same as expected="8.3" ** ~~~ ** Possible Invalid Numerics or other problems ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination. ...Summary of Errors that led to program termination: ..... Reference severe error count=3 ..... Last severe error=IP: Possible incorrect IDD File ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning). ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 3 Severe Errors; Elapsed Time=00hr 00min 0.34sec
My question is how i can fix it ??? and why it tell me that:
** Severe ** IP: Possible incorrect IDD File** ~~~ ** IDD Version:"IDD_Version 8.3.0"** ~~~ ** Version in IDF="8.3" not the same as expected="8.3"** ~~~ ** Possible Invalid Numerics or other problems** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination....Summary of Errors that led to program termination:
Help me pleaseeeeeeee
Happy new year!!!!!…
8.3.0************* IDF Context for following error/warning message:************* Note -- lines truncated at 300 characters, if necessary...************* 829 Construction,************* indicated Name=PELLE001************* Only last 10 lines before error line shown.....
************* 832 AIR WALL2, !- - Layer 2************* 833 X-LAM, !- - Layer 3************* 834 POLYSTYRENE2, !- - Layer 4************* 835 PANNELLO VIP, !- - Layer 5************* 836 POLYSTYRENE2, !- - Layer 6************* 837 X-LAM, !- - Layer 7************* 838 LANA DI ROCCIAS, !- - Layer 8************* 839 VANO IMPIANTI, !- - Layer 9************* 840 LANA DI ROCCIAS, !- - Layer 10************* 841 LASTRA IN GESSOFIBRA, !- - Layer 11** Severe ** IP: IDF line~841 Error detected for Object=CONSTRUCTION** ~~~ ** Maximum arguments reached for this object, trying to process ->LASTRA IN GESSOFIBRA<-************* IDF Context for following error/warning message:************* Note -- lines truncated at 300 characters, if necessary...************* 985 Construction,************* indicated Name=ROOF001************* Only last 10 lines before error line shown.....************* 988 TRAVETTI, !- - Layer 2************* 989 TAVOLATO, !- - Layer 3************* 990 POLYSTYRENE2, !- - Layer 4************* 991 PANNELLO VIP, !- - Layer 5************* 992 POLYSTYRENE2, !- - Layer 6************* 993 X-LAM, !- - Layer 7************* 994 LANA DI ROCCIAS, !- - Layer 8************* 995 VANO IMPIANTI, !- - Layer 9************* 996 LANA DI ROCCIAS, !- - Layer 10************* 997 LASTRA IN GESSOFIBRA, !- - Layer 11** Severe ** IP: IDF line~997 Error detected for Object=CONSTRUCTION** ~~~ ** Maximum arguments reached for this object, trying to process ->LASTRA IN GESSOFIBRA<-** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.** Severe ** IP: Possible incorrect IDD File** ~~~ ** IDD Version:"IDD_Version 8.3.0"** ~~~ ** Version in IDF="8.3" not the same as expected="8.3"** ~~~ ** Possible Invalid Numerics or other problems** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination....Summary of Errors that led to program termination:..... Reference severe error count=3..... Last severe error=IP: Possible incorrect IDD File************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 3 Severe Errors; Elapsed Time=00hr 00min 0.34sec
My question is how i can fix it ??? and why it tell me that:
** Severe ** IP: Possible incorrect IDD File** ~~~ ** IDD Version:"IDD_Version 8.3.0"** ~~~ ** Version in IDF="8.3" not the same as expected="8.3"** ~~~ ** Possible Invalid Numerics or other problems** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination....Summary of Errors that led to program termination:
Help me pleaseeeeeeee
Thanks and Happy new year!!!!!…
ay be other issues with your geometry, but this is usually the issue people run into.)
Rays will lose energy much more slowly when a room is very reflective, but such conditions only really exist with polished painted concrete. I don't know how many such rooms you've ever been in. I can count them on one hand - and I've been to acoustic reverberation chambers on 3 continents.
Pachyderm works with a ray decimation algorithm. This means that a ray will be traced out to the cutoff time, unless it has lost enough energy that its further contribution to the impulse response is negligible. At this time, the ray is discontinued. So, the more absorption in the room, the less time it will take to run the simulation. So, more realistic absorption coefficients will allow a model to run in a more reasonable amount of time.
Gypsum board/Plasterboard will typically be between 8 and 11 percent at mid and high frequencies, and higher at low frequencies, for example. Concrete, unless polished and painted, is still a little porous, so you can probably make it 3 to 5 percent.
Regarding sources and receivers, adding more receivers adds almost nothing to calculation time (until the every end, when it extrapolates a pressure response, anyway). This is because the receivers are entered into a spatial partition system, which allows it to be done in an optimized way. Adding multiple sources will effectively multiply the calculation time by the number of sources, because the simulation needs to be repeated for each source individually.
Hopefully this helps you figure out how to run simulations with reasonable run times.
Arthur…
ncepts and features of Grasshopper at an accelerated pace in an instructor-led online environment.
Session Schedule: 9:00am-10:45am Lecture/Classwork Break 10:45am-11:00am 11:00am-12:30pm Lecture/Classwork 12:30pm-1:00pm Questions (optional participation)
Details: An outline of the class material is available here. The class will be conducted in English using the GoToTraining software. You will need Rhino 4.0 for Windows or the Rhino 5.0 for Windows beta installed. You will also need the latest build of Grasshopper. You may use the Rhino 4.0 for Windows evaluation version, however you will be limited to 25 saves. Using the Rhino for OSX WIP is not acceptable for this class.…