in the desired order.
0 = 0
1 = 1
2 = 6
3 = 7
4 = 8
5 = 9
6 = 12
7 = 13
8 = 2
9 = 3
10 = 4
11 = 5
12 = 10
13 = 11
Where the first number is the index and the second number is the actual sorting key. Then you sort these keys while sorting your curves in parallel using the A input of the Sort component.
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
x and min values for x,y,z and calculate energy for each optionand collect these results in excel sheet ...
option No. x y z Annual coiling demand(by DIva)
1 10 10 10
2 10 15 20
3 11 10 19
4 12 14 17
5 15 16 15
6 16 11 14
7 18 12 12
.
.
etc
Regards ...
hossam
Hossam.wefki@gmail.com…
ll these 12500 points.
Group 1 would represent the point located at 0, 5, 10, 15, 20 etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc.
I can create the pattern but the selection of points are all the points in row 0 and then all the points in row 5 and so on.
I would like the selection of points to start at the bottom left, and sequentially continue to the right and then continue on the 2nd row (left to right & bottom to top). i am hoping the pattern i am trying to achieve is more understood with the quick screen capture I uploaded.
the end goal is to be able to select all the points in the grid that are in each pattern.
Thanks in advance for any guidance with this. …
Added by Alyne Rankin at 6:53am on October 11, 2017
7, 9, 12 and 13 to be able to rotate freely around the y axis at nodes 2, 3, 6, 7, 10 and 11 respectively. The last 2 conditions, for elements 12 and 13, doesn't give any problems, but the first 4 does.
Any help?
…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…