very surface i.e. 33, which you are trying to match up with 3 surfaces in a single list. Which is the second issue you would need to graft the single list of surfaces before inputing them to both the P and C inputs. That way you are making GH Match the first surface with the first set of points and so on. and not every surface with each set of points.
To sort out the Data structure coming from the grid use a pathmapper with {A;B;C;D}(i) --> {A;B}…
Added by Danny Boyes at 4:11am on February 7, 2011
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…
re-organized code, the preview at "(1)" is static, before the simulation; it is hidden to see the simulation. The preview at "(2)" is the simulation, which traces each tool path and then reveals each one piped.
…
Added by Joseph Oster at 5:56pm on November 1, 2017
} (N=11) {0;1} (N=11) {0;2}(N = 11) {0;3}(N = 11) {0;4}(N = 11)
2. I run the Points that are coming out from the Divide Curve Components through the Path Mapper components with this definition:
{A;B} (i) > {A} (i)
3. I run data coming out from Path Mapper component through:
a) Parameter Viewer component and the result is:
{0} N=11 (data with 1 branches)
b) Point > Panel and the result is:
collection of 11 point (N=11) which is the exactly the same as the collection of point belonging to {0;4} (N = 11).
So, here is the question:
why the collection of points coming out from the Path Mapper {A;B} (i) > {A} (i) component is the same as the collection of points belonging to the curve {0;4}(N = 11) ?
Anyway ... It 's the first time I ask a question here... so I would like to thank you for what you do with your work! Thank you! You are really great!…
First use a series component with start=1, step=42, count=3
Use the output to create a new series component with start=existingseries, step=1, count=11
5 8, and then the following values are obtain as the last one (8) plus 3, then this last one (11) plus 5, and then this last one (16) plus 8, and then it starts again: 24+3, 27+5, 32+8...
Thanks
…
Added by Jesus Galvez at 5:17am on November 27, 2012
e 18:40? Perhaps this is a Thunderbird issue? Either way, it's no big deal for me, just a bit confusing...
Apart from this detail I really like the new (web) forum, it really encourages you to interact with other users, rather than just posting occationally, which is a good thing!…
etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc. "
except in data, the branches start at 0, so 'group 1' is branch 0
as for the order of your points, that depends on the input prior sorting...
yrs …
x and min values for x,y,z and calculate energy for each optionand collect these results in excel sheet ...
option No. x y z Annual coiling demand(by DIva)
1 10 10 10
2 10 15 20
3 11 10 19
4 12 14 17
5 15 16 15
6 16 11 14
7 18 12 12
.
.
etc
Regards ...
hossam
Hossam.wefki@gmail.com…