ards to the number before the start number...
i.e. 9, 0, 1, 2, 3, 4, 5, 6, 7, 8
then it will need to repeat this pattern (continuing to count upwards) and the repeat number is based on a slider (for example 3 in the case illustrated below):
9, 0, 1, 2, 3, 4, 5, 6, 7, 8
19, 10, 11, 12, 13, 14, 15, 16, 17, 18,
29, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29,
if anyone has any ideas on how to create this series it would be great
M.…
e
7. True
8. True <-- this one
9. True
10. False
11. True
12. False
13. True
14. True <-- this one
15. True
16. False
17. True
18. False
19. True
20. True <-- this one
21. True
22. False
23. True
24. False
25. True
26. True <-- this one
27. True
28. False
29. True
30. False
31. True
32. True <-- this one
33. True
Any idea how I can solve this?
Thanks!…
ectural context.
We will work with 5 projects that meet the conditions to be re-thinked nowadays in parametrical terms. { FOA : World Trade Center / MAD OFFICE : 800M Tower / TOYO ITO : Relaxation Park / FOSTER & PARTNERS : Gherkin Tower / FREE : Soumaya Museum }
We will produce dynamic objects defined by parameters and modified in realtime.
We will learn to discretize, facet and panel in a non homogeneous way.
We will work with restrictions to determine our shapes, obtaining unpredictable results.
And we will take the control of what we produce : by measuring , visualizing and optimizing our parametric forms.
2 Groups / 30 students max :
Thursdays : 25 Apr ,02 ,09 ,16 & 23 May
Saturdays : 27 Apr ,04 ,11, 18 & 25 May
Fee : 73 € / student…
Added by Carlos Bañón at 10:26am on April 18, 2013
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
erations, is not it?
This is what I finally want and how I plan to do it:
In the starting tree, points are listed accordingly to the (11) 4-side-panels they belong to. I need to do a tree where each of the 11 lists contains not the points composing the panels but the points code of the points composing the panels. the point code is the number in the flattened list that refers to the points (like, panel 1 is made of points n 0,1,4,18, and so on). To do this, I suppose that I will use my tree of 11 lists of 33 true-false values, and apply it to cull 11 times a series of numbers from 0 to 32. I ll post it if it works!…