l use Rhino 4.0 and corresponding GH version, as a result i could not open your Rhino file.
Hence in your definition as i see,
1) Spring Force-1 -Connection has 11 'inter' components. The inter components do not have any input data and hence 'orange'. What are the inputs for 'inter'?
2) Spring Force - 2 -'Connection'has 1 point component. Rest length & Cut off has 'mass addition' data. This force is also orange, could u throw a light on this please?
3) Pull to surface - both forces has no point input, hence it is orange too. could u throw a light on this too please?
4) There are 2 x Cartesian product components not connected to anything.
I realise that partially it could be because i'm using lower version of Rhino. However, ur input will be highly appreciated.
Kind Regards,
Agneesh…
e now contains (40x3x11=)1320 points with a branch structure of {0-39,0-2} i.e
{0;0}
{0;1}
{0;2}
{1;0}
...
{39;2}
with each branch containing 11 points.
I now want to create lines from the points on line {x;0} to {x;1}, {x;1} to {x;2}, and {x;2} to {x;0}, which will give me a triangular grid on each triangle. How do i do this? I think I need to split the tree 40 times to give me 40 single layered trees but I imagine there's a cleverer way of doing this!
This feel like it should be simple, but I;m having trouble working with the double-layered branch structure. Any help would be greatly appreciated!
Thanks,
Matt…
keep the same number of branches.
The way I'm doing it now has the inconvenience of only working for this particular number of branches, and I would like a more general way. Do I need a script or can I solve it with components, path mapper, etc?
-Also, and this one is probably simple but I can't seem to figure it out: I have a tree structure as in fig B, and I want to pick out certain series of branches from it, for example {1;0} to {2;11}. (PathGen seems to only go from {0;0} to a specified item?) So I want to be able to plug in a choice of numbers, and dispatch those branches into separate trees/cull them somehow. What am I missing? In general, I've failed to find a way to pick out all of the "uppermost" level of branches, eg {3;x}.
Any help greatly appreciated!…
rights to register the "mapwingis.ocx" file.Francesco, would you be patient just a tiny little bit, so that we could try something else? I would be grateful if you could.
1) Close Grasshopper and Rhino2) Run the Revo Uninstaller Pro and uninstall your MapWinGIS application along with removing all the leftovers from the registry.3) Restart your PC, and once it boots again, make sure that you are logged in as an Adminstrator.4) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".5) Turn off your Antivirus, which ever it is.6) Download the 64 bit version of v4.9.4.2 MapWinGIS.7) Right click on downloaded MapWinGIS-only-v4.9.4.2-x64.exe file, and choose "Properties". If there is "Unblock" button click on it, and then click on "OK". If there is no "Unblock" button, just click on "OK".8) Left double click on MapWinGIS-only-v4.9.4.2-x64.exe file and install it to "C:\dev\MapWinGIS" folder. Choose "Full installation" during installation process!9) In your Start menu's search box type: "CMD". Once the "Command prompt" appears do not left click on it! Instead right click on it, and choose "Run as Administrator".10) A command prompt window will open. Type the following command:
"your_regsvr32_folder_path\regsvr32.exe" /u /s c:\dev\mapwingis\mapwingis.ocx
If command does not result in an error message, then type this one afterwards:
"your_regsvr32_folder_path\regsvr32.exe" /s c:\dev\mapwingis\mapwingis.ocx
11) If no error appeared again, then open your Rhino and Grasshopper and check what Gismo_Gismo component prints from its "readMe!" output.If errors appeared, it would be nice if you could post their screenshots.…
Added by djordje to Gismo at 5:46am on March 27, 2017
analysis with Honeybee. Here is the tentative outline:
09:00 - 09:30
What is Honeybee, Introduction to daylighting simulation
09:30 - 11:00
Geometry preparation workflows, Radiance materials
11:00 - 11:10
Break
11:10 - 12:30
Sky types, Run your first simulation
12:30 - 13:30
Lunch
13:30 - 15:00
Daylighting analysis types, Result visualization, Getting started with annual daylight
15:00 - 15:15
Break
15:15 - 16:00
Annual daylight analysis and Results interpretation
Check MEBD page for more information including the registration link: http://www.mebd-penndesign.info/Honeybee-MEBD-Workshop-PennDesign
Please feel free to forward this to anyone of interest.
Cheers,
Mostapha
PS: Thank you all for the kind comments and emails for the Ladybug workshop. We recorded the workshop and are in the process of figuring out how to share it with the public. I will send an update once it is uploaded.
…
思った感じになりません。
balls の代わりにplanarカーブを直接入れてみましたがエラーが出ます。
ファンクションにしてみたところ、forループので作った数値が反映されていません。
ファンクションのインスタンス?を出力していないと思い上記のようにしましたがエラーが出てしまいます。
以上の事から自分の認識が正しいのかよくわからなくなりました・・・
python自体の深いところをわかっているわけではないので余計こんがらがりました。
そこで、for b in ballsはどのような条件または使い方であれば使えるのでしょうか?
そして、上記のように別のオブジェクトに対しての使い方はどのようにすればできるのでしょうか?
2:同じファンクション内のdist = rs.Distance(self.pos,b.pos)についてですが
この文章も for b in balls によってbはBallのインスタンスであると定義?されたためb.posがbの位置であると分かるのでしょうか?
pythonは定義しなくても動いてしまうのでどのような時に使えるのか文章見ただけではよくわかりません・・・
大変細かいことかもしれませんが、よりpythonをしっかりと理解するためにも、どなたかわかる方ご教授いただけると幸いです。…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
the use of digital technologies as architectural design tools. The workshop " Computer Aided Design: parametric design and digital fabrication " aims to do some introductory teaching in the use of some of these tools.
The workshop will focus on the use of computational models of parametric behavior for generating architectural forms. The generative capacity of these models it will be tested in the development of designs defined by repetitive non-standard components, based on the parametric control of its variations and series differentiations. This process will be developed by the use of a three-dimensional modeling software - Rhinoceros, associated with an application for visual programming - Grasshopper.
The last day of the workshop is dedicated to the use of digital manufacturing tools in architecture. Part of the work will take place at the facilities of the Institute of Design of Guimarães (IDEGUI) providing for the use of their laboratories and manufacturing CNC machines (computer numerically controlled).
At the end of the workshop, it is intended the students to understand that the use of digital technologies in architecture can overcome representational functions, and their integration in the design conception, analysis and construction enriches the methodology of project development.
Terms & Participants
The workshop will take place at the School of Architecture of the University of Minho (Campus Azurém, Guimarães) and the Institute of Design of Guimarães (Couros, Guimarães).
The workshop is pointed at students who attend the 3rd year and 4th year from MiArq, EAUM.
The maximum acceptance is 20 students and a minimum of 10 students.
Deadline for entries is April 11 and must be performed by eaum.pac@gmail.com.
Program summary :
Day 23 April 14 -20h
Introduction to 3D modeling in Rhinoceros. Regular geometries, ruled surfaces and NURBS surfaces.
Day 30 April 14 -20h
Parametric design in architecture. Introduction to methods of visual programming.
May 1, 9 -13h 14 -18h
Development of a design idea by the use visual programming processes in Grasshopper.
May 2, 9 -13h 14 -18h
Introduction to methods of digital fabrication. Manufacture physical models of the proposals made.
It is expected that this meeting will take place in the IDEGUI labs.
team:
Bruno Figueiredo ( Lecturer, EAUM )
Paulo Sousa ( PhD candidate , EAUM )
Nuno Cruz ( Invited Lecturer , EAUM )
Cláudia Alvares ( 5th year MiArq student , EAUM )
Javier Bono ( 4th year MiArq student, EAUM )
João Amaro ( 5th year MiArq student, EAUM )…
a nodi, permette di sfruttara le potenza della programmazione, senza necessariamente avere competenze avanzate.
Con Grasshopper potrete avere accesso ai segreti della modellazione generativa, un nuovo linguaggio progettuale che sta cambiando il mondo del design, a partire dalla gioielleria, fino ad arrivare all'architettura.
Durante il corso sarà possibile comprendere le caratteristiche di funzionamento del programma e applicarlo alla creazione di oggetti complessi che potranno essere stampati in 3D, oppure renderizzati. La durata è di 30 ore e alla fine del percorso verrà rilasciato il certificato McNeel.
Il Programma
Il corso spiega i concetti base di modellazione parametrica e generativa. Nello specifico:
Interfaccia e comandi
Parametri e componenti
Interopazione con Rhinoceros
Strumenti di parametrizzazione
Combinazione dati
Data tree
Creazioni di superfici attraverso algoritmi di paneling
Teoria degli attrattori
Gestione strumenti mesh
Creazione di Cluster
Durante il corso saranno proposte esercitazioni pratiche sul campo di utilizzo preferito dallo studente
Il docente
Antonino Marsala, è un formatore certificato McNeel con alle spalle oltre 11 anni di esperienza nel settore della modellazione 3D. Oltre ad occuparsi di formazione, collabora con aziende orafe e di architettura per la messa in pratica dei principi di modellazione generativa, applicandoli a casi reali.
FAQ
Quanto costa il corso?
Il prezzo del corso è di 500,00 € + IVA che potranno essere saldati in una soluzione unica. Nel caso di iscrizione di gruppo, potrà essere applicato uno sconto.
Cosa posso portare e cosa non devo portare all'evento?
Gli organizzatori forniranno computer con il software già installato. Nel caso vogliate portare il vostro computer, vi forniremo una versione trial da 90giorni di Rihnoceros e Grasshopper
Dove posso contattare l'organizzatore per qualsiasi domanda?
antonio@mandarinoblu.com
334 24 20 203
La mia registrazione o il mio biglietto è trasferibile?
Si, purchè venga comunicato il cambiamento entro 48 ore dalla partena del corso
…
he sunPath component works. For example if you want to simulate the hours from 8 to 16 it means you want 8 hours from 8 to 9, from 9 to 10,.... from 15 to 16 (8 hours duration period) so you get from the sunPath component (using default timeStep 1) the 9 sun position/vectors 8 9 10 11 12 13 14 15 16 (in the image the yellow suns). The things is that if you ask for a smaller timeStep for example 3 = 20 mins then the additional sun position (in the image the orange suns) are added also after the time limit of h16 so probably when you don't want/need. I understand that when you input a time period there is the ambiguity if the hours are the just 9 (the 9 inputs) or the 8 hours included between pairs of hours, but I would make in a way that it is possible to chose if the extra timeStep after the last hour are added or not. Thank you for your comments.
…