Hello everyone,

Integrate Photovoltaic and Wind generators into your Honeybee models and make the design and financial analysis of renewable energy systems easier with the Beta release of Honeybee generation!

See an example work flow for designing, simulating and analysing a Photovoltaic system below.

Download a Grasshopper and Rhino example file:

https://www.dropbox.com/s/krbszlplj5i40dz/017_HBgeneration%20Rhino%...

https://www.dropbox.com/s/lxneuzal3mipd2q/017_HBgeneration.gh?dl=0

See a quick introduction and tutorial videos here: https://www.youtube.com/playlist?list=PLrx2KnyhaJ5YXo5hpk8Q9q4Vy99O...

1. Select a building to mount a photovoltaic generator on (seen in Rhino in green). 

2. Select a surface within that building to mount a photovoltaic generator on (seen in Rhino in green).

3. Create a Honeybee context surface from that surface.

4. Place a photovoltaic generator on that Honeybee context surface by using the Honeybee generation component. Honeybee_Generator_PV and connecting the context surface to it's input _HBSurfaces. Then you can specify both the performance and the financial data of the photovoltaic generator.

5. Create a Honeybee generation system which consists of the photovoltaic generator in 4. By using the component Honeybee_generationsystem and connecting 4 to its input PVHBSurfaces_. Then you can specify the annual maintenance cost of this system.

6. Run the simulation in Energy Plus by connecting 5. to the input HBGenerators_.

7. Read the results of the simulation:

- The electricity produced by the Honeybee generation system in 5.

- The net purchased electricity of the facility (the Honeybee zone) to which the Honeybee generation system is attached to. This is the electricity consumed by the facility less the electricity generated by the Honeybee generation system.

- The financial costs of the Honeybee generation system; capital, maintenance and replacement costs.

8. Calculate the net present cost of the Honeybee generation system in 5 assuming a 25 year lifetime.

9. Visualise the net present cost.

Views: 4560

Replies are closed for this discussion.

Replies to This Discussion

Hello Theodoros,

Both the Sandia and Equivalent One Diode models in EnergyPlus, predict the efficiency of PV panels by calculating the back of the panel temperature, however, Sandia model consists of a series of empirical relationships with coefficients that are derived from actual testing. Arguably, it is one of the most accurate prediction models for solar panel generation. 

I know for sure Greg Barker in 2003, working for the NREL implemented the Sandia model in FORTRAN77 as a custom type (Type101) for the TRNSYS computer program. so i guess TRNSYS has this algorithm.

cheers,

Mohamed

The functionality to add sandia models is now available as soon as Mostapha approves it.

https://github.com/mostaphaRoudsari/Honeybee/pull/458.

Please use it like below. I am in the middle of moving continents and jobs but will try to polish it up and add the one diode model next week.

Thanks Anton. It's merged into the master branch now.

Hi Anton

Sorry to piggy back on this. Cool tool btw.

Just a very basic question I guess - if using your pv tools do I need to provide an epconstruction to account for the pv - thinking in terms of reflectance - or does E+ determine this from the HBGenerator inputs?

Thanks

Hi Duncan,

You will need to use one of the three PV models that Energy Plus offers, the Simple model the EquivalentOne-Diode model and the Sandia model. Please see the links to the models below.

 

Hi Anton,

The tool seems very useful and has great potential for scalability! I am trying to use it on a small box model as you have demonstrated in your post but seem to persistently run into an error. From my understanding EnergyPlus is not recognizing my the inverter and generator (called 'inverter1' and 'generator1') created and returns that: 

1. The simulation has not run correctly because of this severe error:
** Severe ** GetPowerManagerInput: ElectricLoadCenter:Inverter:Simple="INVERTER1", invalid entry.

2. The simulation has not run correctly because of this severe error:
** Severe ** GetPowerManagerInput: ElectricLoadCenter:Generators="SYSTEM1", invalid entry.

I have attached the file I used. Any ideas what might be causing this? Thank you!

Attachments:

Hi Antoine,

Thank you for your interest in these components, unfortunately they haven't been given the love and attention that they deserve as I have been so busy these past few months.

The issue here is that the schedule Always On is not being written to the IDF file so the generators can't find it and it the simulation crashes.

I'll talk to Mostapha about this as I believe he has changed some code, this is why this problem is occurring.

Find the working model attached. You will need to use the Run E+ component in this Grasshopper file for now.

There is a lot more functionality that I want to add with these components and they still need to be clean up a fair bit, let me know if you have any suggestions or questions!

Attachments:

Hi Anton, 


That's great for now thanks! Will look forward to seeing what else you get the tool to accomplish in the future. Small note however, the financial analysis tool based on the LB 3D plotter tool isn't working for some reason (no worries it's not really why I'm using this tool for now).


Thanks again!

Hi Guys. I have a question regarding the PVGen component.

> The old component had the surface area input, the current version doesn't have it. How do I input/check the SA of each component?

> I'm not sure if I understood NoParallel and NoSeries correctly. Do they refer to the number of components x-axis and y-axis (respectively, or the other way around?). Since I don't know the SA for each component, how do I calculate the number of components to be placed on the x and y-axis?

>Regarding the power output per module, is it in Watts/m^2?

Thanks.

I'm also having some problems with the Generators when they're plugged in into the EP Simulation...

(1) Using the same setup from the tutorials for PV Generators, the EP Simulation gave me this.

(2) When I ran the simulation using either the Old or New version (see .gh file) of the 'Generator:Wind Horizontal Axis' component, the simulation gave me this warning.

I have another question by the way. The old 'Generator:Wind Horizontal Axis' component only required 2 inputs (boolean for size, and the name). The new component though, even though I already set those two values was still asking for the specs from simpleOranalytical to turbinecost. Is this a bug?

Attachments:

Hi Pin,

Apologies for the delay in my reply, I was away over the weekend 

1) This is indeed a bug and one I am aware of I need Mostapha's help to fix this since you are using the component. See: https://github.com/mostaphaRoudsari/Honeybee/issues/487

Do you need this functionality ASAP?

2) This is also a bug, however that one is a quicker fix, see a working component attached, please use the newer version of the component and check out the E+ wind turbine guide for the difference between analytical and simple turbines

http://bigladdersoftware.com/epx/docs/8-4/input-output-reference/gr...

Attachments:

Hi Anton,

It's not urgent as of the moment but I might need it the next weeks or so.

You might have missed my other post regarding the PVGen Component (http://www.grasshopper3d.com/xn/detail/2985220:Comment:1549495). I'm having trouble understanding some of the workings behind the component.

Thanks.