m rnd As New random(666)
Dim field As New gh_field
Dim crvlist As New list(Of curve)
For i As Integer = 1 To 100 Dim pc As New gh_pointcharge
pc.Charge = rnd.NextDouble
pc.Location = bx.PointAt(rnd.NextDouble, rnd.NextDouble, rnd.NextDouble)
field.Elements.Add(pc)
Next
For i As Integer = 1 To 500 Dim p As New point3d(bx.PointAt(rnd.NextDouble * 0.5 + 0.25, rnd.NextDouble * 0.5 + 0.25, rnd.NextDouble * 0.5 + 0.25))
Dim pts As point3dlist = field.SolveSteps(p, 0.1, 30, gh_differentialsolver.RungeKutta4)
Dim crv As nurbscurve = nurbscurve.CreateInterpolatedCurve(pts.ToArray, 3)
crvlist.add(crv)
Next
a = crvlist
…
tetgen to directly create the 3D Delaunay) until it comes to the pipe variable. It just throws out empty parameters. If I have one pipe and set the radii manually, it works tough. I have no idea what could be wrong there. I'll attach the def, maybe its an issue with my GH Installation?
(Attention: Used regular Pipe instead, solution may freeze your PC some 30 seconds or so.)
…
making a cluster (image 3) )Also here is what I get when I double left click on that newly created cluster:
There is not input/output parameters inside that window.Just information about Name, description, author, icon...…
is capture to be done AFTER the whole solution is run and BEFORE the timer gives the input for the next frame to begin.
Does anybody know how to make this happen?
How it should look:
What is automatically generated:
(the geometry in the back is missing, I think because the capture happens before the solution is finished)…
Specifically point number 3. The Latest Activity feed keeps going back to February for me. This happens across devices and appears to occur more or less randomly.
ction to a new sheet it runs properly...
Is it known that sort points isn't reliable?
Is it a decimal error? As in pos. 2 is 0.00000000001 closer than 3 in x?This could only be the case if when I internalise data it rounds the number, which isn't the case ?…
Added by Peter Fajers at 1:25am on February 13, 2015
e them in 3 different layers, only spent few seconds to play with the slider and then baked them up to Rhino and they are still blocks instances :) told my friend about Elefront and all of them are excited. dont have to rely on other rendering plug in anymore.…
which I understand analyses only 2 octave bands (500 Hz and 2 kHz) instead of the 8 bands (for which the STI component requires background noise.)
Or have I misunderstood this metric and the three values mean something else?
For reference / a minimal definition I have the open office example (gha and 3dm attached) which includes 20 receivers and the sti results show three values for each (see the image).
Thanks in advance Roly…