ll these 12500 points.
Group 1 would represent the point located at 0, 5, 10, 15, 20 etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc.
I can create the pattern but the selection of points are all the points in row 0 and then all the points in row 5 and so on.
I would like the selection of points to start at the bottom left, and sequentially continue to the right and then continue on the 2nd row (left to right & bottom to top). i am hoping the pattern i am trying to achieve is more understood with the quick screen capture I uploaded.
the end goal is to be able to select all the points in the grid that are in each pattern.
Thanks in advance for any guidance with this. …
Added by Alyne Rankin at 6:53am on October 11, 2017
maintained on a branch as it is before the row transformation.
For example, after the cross referenced transformation, I get a data tree where each row is essentially flattened into a single data tree of 180 items as opposed to 18 items for each branch. I am looking to create an indice for each row of branches something like:
{0;0;18}
{1;1;18}
{2;2;18}
etc...
Thanks again,
Erik…
Added by johnnyUtah05 at 2:52pm on November 26, 2015
re going any further answer these critical questions:
1. Is a DataTree a List of Lists?
2. Can you sample in a DataTree 1 dog, 66 sardines and 666 double numbers?
3. What are the so called path dimensions?
4. Is a Matrix a kind of DataTree or a DataTree is a kind of Matrix?
…
as follows.
We have a grid which consists of a collection of columns, where each column consists of a list of points. You said flattening is out of the question, so we need to cull items from each list individually.
Let's say our culling pattern is KDDDKDD (repeat as needed). K = Keep, D = Ditch. If a column contains 18 points, the pattern needs to be repeated until it is 18 items long. In this case:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
K D D D K D D K D D D K D D K D D D
We can now cull each column, but they will all be culled in the same way. By shifting the pattern one more index for each column, we can cycle the culling.
The fix incidentally is to Shift the pattern PRIOR to repeating it. Then it works as expected:
--
David Rutten
david@mcneel.com
Tirol, Austria…
Added by David Rutten at 2:49pm on October 2, 2013
returned to GSA, it is solving. You might have to reset result scales using the GSA button.
Cheers,
Jon
Checking Input Data - this may take some time.
________________________________________
Data checks commenced at 23/08/2017 4:59:18 PM.
Checking input data for static analysis by GSS.
Shortest element (element 9) is 5 m long.Longest element (element 1) is 6 m long.
Data checks completed at 23/08/2017 4:59:18 PM. No errors or warnings found.
Analysis commenced at 23/08/2017 4:59:18 PM.
Analysis by Gss Static analysis
Initialising results modulesSolving for displacementsSolution statisticsSparse Parallel Direct 12 active nodes 14 active elements 2 analysis cases 24 degrees of freedom Minimum degree ordering 90 terms in stiffness matrix Maximum stiffness is 4.804e+009 at node 4 in direction z Minimum stiffness is 3.132e+008 at node 2 in direction yy Condition number of the stiffness matrix is ~ 5328. Maximum relative error in displacements will be 2.4e-10 percent. Factorization in 109 msSolving for element forces and reactionsCalculation completeAnalysis completed with no errors
Analysis completed at 23/08/2017 4:59:18 PM.Analysis time: 0.172 seconds
…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…