rights to register the "mapwingis.ocx" file.Francesco, would you be patient just a tiny little bit, so that we could try something else? I would be grateful if you could.
1) Close Grasshopper and Rhino2) Run the Revo Uninstaller Pro and uninstall your MapWinGIS application along with removing all the leftovers from the registry.3) Restart your PC, and once it boots again, make sure that you are logged in as an Adminstrator.4) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".5) Turn off your Antivirus, which ever it is.6) Download the 64 bit version of v4.9.4.2 MapWinGIS.7) Right click on downloaded MapWinGIS-only-v4.9.4.2-x64.exe file, and choose "Properties". If there is "Unblock" button click on it, and then click on "OK". If there is no "Unblock" button, just click on "OK".8) Left double click on MapWinGIS-only-v4.9.4.2-x64.exe file and install it to "C:\dev\MapWinGIS" folder. Choose "Full installation" during installation process!9) In your Start menu's search box type: "CMD". Once the "Command prompt" appears do not left click on it! Instead right click on it, and choose "Run as Administrator".10) A command prompt window will open. Type the following command:
"your_regsvr32_folder_path\regsvr32.exe" /u /s c:\dev\mapwingis\mapwingis.ocx
If command does not result in an error message, then type this one afterwards:
"your_regsvr32_folder_path\regsvr32.exe" /s c:\dev\mapwingis\mapwingis.ocx
11) If no error appeared again, then open your Rhino and Grasshopper and check what Gismo_Gismo component prints from its "readMe!" output.If errors appeared, it would be nice if you could post their screenshots.…
Added by djordje to Gismo at 5:46am on March 27, 2017
on the division points (see rhino screenshot below, left side is what I'm describing. there is also a note in the screenshot of the GH file)
Unfortunately it doesn't work for multiple cell inputs.
I've also tried flattening the points into one big list and re-creating the polylines with sublists but with no luck. The points are not ordered the way it would need to be to use sublists from domains created by 2 series of numbers. So this is problematic becuase each cell has a different number of vertices. That method would work if I can create unevenly spaced intervals that match the number of vertices on a given input, but I'm not sure how to do that.
Like would it be possible to create a series of numbers whos step size varies with each step? e.g. series that starts at 0, steps up in size 5, then 7, then 11, etc. ant there are x amount of values in the series?
Any ideas how to get this working? Either with this definition or a different method?
Thanks,
Brian…
Added by Brian Harms at 5:40pm on October 15, 2011
e técnicas avanzadas de modelación 3d y su fabricación digital (corte láser e impresión 3d). Se utilizara Rhinoceros y Grasshopper, no es necesario tener conocimiento previo de los programas, únicamente manipular algún programa CAD.
Fechas:
Miercoles 13: 18:30 a 22:30Jueves 14: 18:30 a 22:30Viernes 15: 18:30 a 22:30Sábado 16: 11:00 a 14:30 y de 15:30 a 21:00Domingo 15: 11:00 a 14:30 y de 15:30 a 21:00
Fecha límite de Pago: lunes 11 de Junio del 2012Estudiantes: $160.000Profesionales: $220.00
Descuento para integrantes de Makerspace del 40% (5 cupos únicamente)
Importante:
Todos los niveles de experiencia son bienvenidos el único requisito es tener un entendimiento básico de los programas CAD y una actitud positiva hacia el aprendizaje de dichas herramientas. Necesitas llevar una laptop, nosotros te instalamos los programas de prueba.
Si planeas venir de fuera de la ciudad avísanos y te pondremos en contacto con otras personas que también vayan a hacerlo para en caso de desearlo puedan compartir su lugar de estancia.
Al participar en el workshop obtienes el 50 % de descuento en la licencia educacional Rhinoceros por medio de Rhino Chile.
Proceso de Inscripción:
El participante deberá pagar la matrícula haciendo un depósito bancario a la cuenta que aparece a continuación.
Banco: Estado
Nombre: Luis de la Parra Galván
No. Cuenta: 00169946655
Para obtener los datos restantes para hacer una transferencia o depósito mandar un mail a info@chidostudio.com
El depósito mínimo para reservar la matrícula es del 50% el resto deberá ser cubierto el día del evento.
Una vez que el depósito se haya llevado a cabo el participante deberá enviar a este correo info@chidostudio.com los siguientes datos:
Nombre completo
Email
Teléfono
Institución educativa u Oficina
Archivo adjunto del recibo del depósito bancario
En cuanto recibamos la información immediatamente nos pondremos en contacto para especificar los pasos a seguir.
Contacto Santiago [Sede]
Luis de la Parra
Cel: 714-660-33
info@chidostudio.com
http://www.facebook.com/Chidostudio
Todos los mails se responden en un máximo de 24 horas.
Muchas gracias por tu interés saludos…
R Light Studio - Georg Sochurek Schnelle Beleuchtungsoptimierung mit HDR Light Studio: HDRI-Environment-Maps in Echtzeit ganz einfach erstellen und bearbeiten 10:45 - 11:45: C4D und Adobe Photoshop - Christoph Schindelar Prototyping für einen Wintersportartikel-Hersteller mit Cinema 4D 12:00 - 13:00: Autodesk 3ds max - Daniel Daghofer Software für 3D-Modellierung und Animation 13:30 - 13:30 Pause 13:30 - 14:30: MODO - Mathias Zellerhof Produktdesign leicht gemacht - mit modo 701 von TheFoundry 14:45 - 15:45: Rhino 5 - Dipl. Ing. Fabio Palvelli Advanced NURBS-Modelling mit Rhino 5 für Designer und Architekten 16:00 - 17:00: Autodesk Maya - David Wuchte Umfassende 3D-Animationssoftware 17:15 - 18:15: 3D Coat - Christoph Schindelar Feinmodellierung (Sculpting) & Design von Handy-Designelementen mit 3D Coat Zusätzlich haben Sie die Möglichkeit in den Pausen / im Anschluß div. Hardware zu testen / anzusehen: Monitore: CG Serie von EIZO (inkl. Swing Sensor/Colorimeter) EIZO Foris mit EIZO Spyder EIZO Touchscreen NEC Spectraview Reference inkl. X-Rite Colorimeter Stiftdisplays: WACOM Cintiqs 3D Mäuse: SpaceMouse Pro SpacePilot Pro…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
l use Rhino 4.0 and corresponding GH version, as a result i could not open your Rhino file.
Hence in your definition as i see,
1) Spring Force-1 -Connection has 11 'inter' components. The inter components do not have any input data and hence 'orange'. What are the inputs for 'inter'?
2) Spring Force - 2 -'Connection'has 1 point component. Rest length & Cut off has 'mass addition' data. This force is also orange, could u throw a light on this please?
3) Pull to surface - both forces has no point input, hence it is orange too. could u throw a light on this too please?
4) There are 2 x Cartesian product components not connected to anything.
I realise that partially it could be because i'm using lower version of Rhino. However, ur input will be highly appreciated.
Kind Regards,
Agneesh…
keep the same number of branches.
The way I'm doing it now has the inconvenience of only working for this particular number of branches, and I would like a more general way. Do I need a script or can I solve it with components, path mapper, etc?
-Also, and this one is probably simple but I can't seem to figure it out: I have a tree structure as in fig B, and I want to pick out certain series of branches from it, for example {1;0} to {2;11}. (PathGen seems to only go from {0;0} to a specified item?) So I want to be able to plug in a choice of numbers, and dispatch those branches into separate trees/cull them somehow. What am I missing? In general, I've failed to find a way to pick out all of the "uppermost" level of branches, eg {3;x}.
Any help greatly appreciated!…
para poder parametrizarla - Entender cómo se gestionan los datos con Grasshopper - Asociar formulaciones matemáticas a modelos paramétricos - Panelizar y triangular superficies - Parametrizar estructuras sencillas - Saber deformar modelos tridimensionales paramétricamente - Elaboración de algoritmos simples y aplicarlos a modelos tridimensionales - Exportar e importar tablas de datos
El curso será impartido por dos Authorized Rhino Trainers.
También te informamos de que hemos renovado el temario del curso, preparado específica y exclusivamente por nosotros, y que es revisado y ampliado continuamente, gracias a la experiencia de cursos anteriores. El curso tiene un formato intensivo de 18 horas, cuyo horario es: - viernes, de 16 a 20; - sábado, de 10 a 14 y de 16 a 20; - domingo, de 11 a 14 y de 16 a 19.
Si estás interesado en apuntarte, contáctanos en: cursos@frikearq.com…
berfläche des Grasshopper Programms
Funktionsprinzip eines grafischen Algorithmus-Editors (Datenfluss)
Unterscheidung von Parametern (Datentypen) und Komponenten (Datenverarbeitung)
Erzeugung, Bearbeitung und Analyse von Geometrie-Typen: Punkte, Vektoren, Linien, Kurven, Flächen (surfaces, brep) und Netze (meshes)
Strukturierung der Daten anhand von Listen und Bäumen
unterschiedliche Verknüpfungsmöglichkeiten von Parametern (data matching)
praxisnahe Grundlagen der Geometrie und Vektorrechnung für generatives Design
effizienter Aufbau von parametrischen Modellen anhand Übungsaufgaben
Auszug von Daten aus Modellen für die Fertigung; Daten aus Tabellen (Excel, CSV) importieren, exportieren
Einsatz von benutzerdefinierten Komponenten (custom components)
Vorkenntnisse: Rhinoceros3d Benutzeroberfläche der Software: Englisch Unterrichtssprache: Deutsch, auf Wunsch auch Englisch
Details und Anmeldung:
www.vhs-stuttgart.de
Dieser Kurs wird in Kooperation mit ifBau gGmbH und VHS Stuttgart angeboten, und wird von ifBau als Fortbildung für Mitglieder der Architektenkammer BW anerkannt.
Trainer: Peter Mehrtens
Kursdauer: 3 Tage / 8 Stunden pro Tag
Freitag, 24.01.2014, 09:00-17:00 Uhr Samstag, 25.01.2014, 09:00-17:00 Uhr Sonntag, 26.01.2014, 09:00-17:00 Uhr Ort: VHS Stuttgart, Fritz-Elsas-Str. 46/48
Teilnahmegebühr: 510,00 € Teilnehmerzahl: 4-10 Personen
…
gh, when I bake, the geometry suddenly exists in rhino.
Second, I can seem to figure out how to set default numeric values in the component.
Protected Overrides Sub RegisterInputParams(pManager As Grasshopper.Kernel.GH_Component.GH_InputParamManager)
pManager.AddPointParameter("Focal Point", "FP", "The focal point", GH_ParamAccess.item)
pManager.AddNumberParameter("Focal Point Horiz Dist", "D", "Focal point distance from performance boundary", GH_ParamAccess.item)
pManager.AddNumberParameter("Focal Point Height", "H", "Focal point height above performance boundary", GH_ParamAccess.item)
pManager.AddPointParameter("First Row Start Point", "FR", "Location of first row in tiered seating", GH_ParamAccess.item)
pManager.AddNumberParameter("First Row Horiz Dist", "FRD", "First row distance from performance boundary", GH_ParamAccess.item)
pManager.AddNumberParameter("First Row Height", "FRH", "First row height above performance boundary", GH_ParamAccess.item)
pManager.AddNumberParameter("C Value", "C", "C value", GH_ParamAccess.item)
pManager.AddNumberParameter("Row Width", "RW", "Row width", GH_ParamAccess.item)
pManager.AddIntegerParameter("Number of Rows", "RN", "Number of Rows", GH_ParamAccess.item)
pManager.AddIntegerParameter("Construction Tolerance", "CT", "Construction Tolerance: 1=1in, 2=1/2in, 4=1/4in, 8=1/8in", GH_ParamAccess.item)
pManager.AddNumberParameter("Max Riser Height", "MR", "Maximum riser height allowed", GH_ParamAccess.item)
pManager.AddGeometryParameter("Spectator", "S", "Seated/Standing spectator", GH_ParamAccess.item)
End Sub
Protected Overrides Sub RegisterOutputParams(pManager As Grasshopper.Kernel.GH_Component.GH_OutputParamManager)
pManager.AddLineParameter("Sightlines", "SL", "Sightlines", GH_ParamAccess.list)
pManager.AddLineParameter("C Value", "CL", "Line represents C value height", GH_ParamAccess.list)
pManager.AddLineParameter("Ground Line", "GL", "Ground Line", GH_ParamAccess.list)
pManager.AddLineParameter("Tier tread", "TR", "Line represents tier treads", GH_ParamAccess.list)
pManager.AddLineParameter("Risers", "RI", "Line represents risers", GH_ParamAccess.list)
pManager.AddGeometryParameter("Spectators", "SP", "Seated Standing Spectators", GH_ParamAccess.list)
End Sub
Protected Overrides Sub SolveInstance(DA As IGH_DataAccess)
Dim newLine As New List(Of Line)
Dim newCValue As New List(Of Line)
Dim rowWidthLineList As New List(Of Line)
Dim floorLineList As New List(Of Line)
Dim riserLineList As New List(Of Line)
Dim leghtList As New List(Of String)
Dim newSeated As New List(Of GeometryBase)
Dim inputPoint As Point3d
If (Not DA.GetData(0, inputPoint)) Then Return
Dim viewPointY As Double
If (Not DA.GetData(1, viewPointY)) Then Return
Dim viewPointZ As Double
If (Not DA.GetData(2, viewPointZ)) Then Return
Dim firstRowPoint As Point3d
If (Not DA.GetData(3, firstRowPoint)) Then Return
Dim firstRowY As Double
If (Not DA.GetData(4, firstRowY)) Then Return
Dim firstRowZ As Double
If (Not DA.GetData(5, firstRowZ)) Then Return
Dim cValue As Double
If (Not DA.GetData(6, cValue)) Then Return
Dim rowWidth As Double
If (Not DA.GetData(7, rowWidth)) Then Return
Dim numberOfRows As Integer
If (Not DA.GetData(8, numberOfRows)) Then Return
Dim M As Integer
If (Not DA.GetData(9, M)) Then Return
Dim maxHeight As Double
If (Not DA.GetData(10, maxHeight)) Then Return
Dim seated As GeometryBase
If (Not DA.GetData(11, seated)) Then Return
Call addNewRow(newLine, newCValue, inputPoint, viewPointY, viewPointZ, firstRowPoint, firstRowY, firstRowZ, cValue, numberOfRows, rowWidth, rowWidthLineList, floorLineList, riserLineList, M, maxHeight, seated, newSeated)
DA.SetDataList(0, newLine)
DA.SetDataList(1, newCValue)
DA.SetDataList(2, rowWidthLineList)
DA.SetDataList(3, floorLineList)
DA.SetDataList(4, riserLineList)
DA.SetDataList(5, newSeated)
End Sub
Public Sub addNewRow(---constructor----)
---additional code----
end Sub…