Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…
dont get you, i am saying sleect numbers in range 1 to 10, starting from 1 with a step of 2.
1 to 10 by 3 = 1 4 7 10
1 to 10 by 5 = 1 6
1 to 10 by 1 = 1 to 10 = 1 2 3 4 5 6 7 8 9 10
Added by Steve Lewis at 3:15pm on November 11, 2013
tree with with 8 branches, each with 3 booleans. flip matrix is then used to have these booleans organized in 3 branches, of each domain, containing 8 booleans of each curve.…
i mean, i want a slider that can do 3 sides, 4 sides, 5, 6, 7, 8, 9 and 10. for the grids because I dont want to use a fixed grid shape such as square grid (4 sides only).
ve a Vertex [V] connected to four other Vertexs [N1-N4].
Each of the has a Value:
V ... 1
N1 ... 5
N2 ... 3
N3 ... 8
N4 ... 11
The Average Filter would set the Value of [V] to
(1+5+3+8+11)/5 = 5,6
The Median Filter would Sort Values and pick the middle one
1,3, [5], 8, 11
Hope that helped...…
nd this is the error text:
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. [4 of 8] Writing Electric Load Center - Generator specifications ...6. [5 of 8] Writing materials and constructions...7. [6 of 8] Writing schedules...8. [7 of 8] Writing loads and ideal air system...9. [8 of 8] Writing outputs...10. ...... idf file is successfully written to : C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\cell room.idf11. 12. Analysis is running!...13. C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\eplusout.csv14. ......
Done! Read below for errors and warnings:
15.
Thanks in advance to all for your help me
Francesco…