he installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin…
another comma separated txt file. I know how to import points (function Import coordinates), but I dont know how to connect them by lines if the only information I have about lines is the list of point numbers which should be connected. The txt file with point coordinates looks like:
-18,-36,-1000-18,-34,-19.728-18,-32,-17.603-18,-30,-15.372-18,-28,-13.121
...
And the txt file with line connections looks like:
1,22,33,44,55,6
...
Which means that I want to connect point 1 with point 2, point 2 with point 3 etc...
Both txt files are attached, thank you for the answer...…
e:
Modulo 1Il workshop è finalizzato a fornire ai partecipanti i fondamenti della modellazione parametrica e generativa attraverso Grasshopper, plug-in di programmazione visuale per Rhinoceros 3D (uno dei più diffusi modellatori NURBS per l‘architettura e il design). Il workshop mira a gestire e sviluppare il rapporto tra informazione e geometria lavorando sui sistemi di involucro in condizioni specifiche. La discretizzazione di superfici (pannellizazione sia Nurbs che Mesh), la modellazione delle geometrie attraverso informazioni (siano esse provenienti da dati di analisi ambientali, da mappe di colore o da database), l’estrazione e la gestione di informazioni richiedono la comprensione delle strutture dei dati al fine di definire un processo che va dalla progettazione alla costruzione.I partecipanti impareranno come costruire e sviluppare strutture di dati parametrici per informare geometrie ‘data-driven’ e come estrarre le informazioni rilevanti da tali modelli per il processo di costruzione.Modulo 2Il workshop, volto a promuovere le nuove tecnologie digitali di supporto alla progettazione e alla fabbricazione, fornirà ai partecipanti gli strumenti per la preparazione, attraverso Grasshopper, dei modelli per il processo di stampa 3d. Il workshop inoltre, darà ai partecipanti i fondamenti dell’uso della stampante 3d e si concluderà con la fabbricazione del proprio modello realizzato durante il corso.
[.] Date:Modulo 1 – 25/26/27 Luglio 2014 – SiracusaModulo 2 – 28/29 Luglio 2014 – Catania
[.] Tutors:Arch. Andrea Graziano (Co-de-iT)Arch. Salvo Pappalardo (Studio Aion)Arch. David Montenegro (Hackspace_Catania)
[.] Luogo:Modulo 1Officina Ermocrate – Viale Ermocrate 7, 96100 – SiracusaModulo 2Hackspace_Catania – Via Grotte Bianche, 112 – Catania
[more info]
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
rsi giornalieri (livello base) dedicati a 4 diversi topic Rhinoceros - 8 febbraio Grasshopper - 16 febbraio Rhino cam - 8 marzo Stampa 3D - 9 marzo
tutor: Amleto Picerno Ceraso, Francesca Viglione, Gianpiero Picerno Ceraso.
. Arduino for interaction (livello base-medio) 15, 16 marzo Il workshop parte dalle basi della programmazione di arduino fino ad arrivare all’interazione tra un oggetto fisico ed un imput informativo tutor: Gianpiero Picerno Ceraso
. Grasshopper advanced: “Complex surface” (livello medio) - 18, 19, 20 marzo Il workshop ha come obiettivo lo sviluppo di superfici complesse rispondenti ad informazioni provenienti dall’ambiente. Il corso parte dalle nozioni di Grasshopper fino ad arrivare alla possibile realizzazione di un oggetto tramite le tecniche di fabbrizazione digitale. tutor: Amleto Picerno Ceraso nb: è richiesta una conoscenza base di Grasshopper
. Emotional design (livello alto) 23, 24, 25 marzo Il workshop verterà sull’acquisizione, registrazione e manipolazione di tali dati/emozioni tramite Grasshopper e il loro utilizzo per controllare i parametri del design di specifici oggetti che diventeranno quindi, essendo customizzanti con le specifiche emozioni dell’utente, istanze e memoria tattile di precise esperienze. tutor: Andrea Graziano nb: è richiesta una conoscenza base di Grasshopper
. Fabricated fashion (livello alto) 26, 27, 28, 29, 30 marzo Il tema del workshop verte sulle tecniche di progettazione digitale applicate al fashion. tutor: Luis e Elizabeth Fraguada nb: è richiesta una conoscenza base di Grasshopper
. Blender (livello alto) - 16, 17, 18 maggio tutor: Andrea Graziano
. Interaction design: Arduino + Grasshopper (livello medio) - 2, 3, 4 maggio Il corso ha l’obiettivo di indagare processi di interazione tra le persone e gli ambienti in cui vivono attraverso il responsive design. nb: è richiesta una conoscenza base di Grasshopper e Arduino. tutor: Amleto Picerno Ceraso del Mediterranean FabLab e Antonio Grillo del FabLab Napoli.
info su costi: http://www.medaarch.com/2765-il-nuovo-calendario-attivita-firmato-medaarch/
…
s helped in the past...but again I must be missing something simple.
here is the code and error--attached are the def and (.3DM) file:
----------------------------------------------------------------------
import rhinoscriptsyntax as rs
import ghpythonlib.components as ghcomp
#print UV
pc = []
maxVecs = []
revVec = []
movedPts = []
pc = ghcomp.PrincipalCurvature(surface, UV)
maxVecs = pc[4]
frames = pc[0]
for vector in maxVecs:
#print vector
tempVec = rs.VectorReverse(vector)
revVec.append(tempVec)
for i in range(len(frames)):
#print frames[i]
print revVec[i]
tempPt = rs.MoveObject(frames[i],revVec[i])
#movedPts.append(tempPt)
vectors = revVec
--------------------------------------------------------------
Runtime error (TypeErrorException): Parameter must be a Guid or string representing a Guid
Traceback:
line 468, in coerceguid, "C:\Users\Aaron\AppData\Roaming\McNeel\Rhinoceros\5.0\Plug-ins\IronPython (814d908a-e25c-493d-97e9-ee3861957f49)\settings\lib\rhinoscript\utility.py"
line 1081, in TransformObjects, "C:\Users\Aaron\AppData\Roaming\McNeel\Rhinoceros\5.0\Plug-ins\IronPython (814d908a-e25c-493d-97e9-ee3861957f49)\settings\lib\rhinoscript\object.py"
line 396, in MoveObjects, "C:\Users\Aaron\AppData\Roaming\McNeel\Rhinoceros\5.0\Plug-ins\IronPython (814d908a-e25c-493d-97e9-ee3861957f49)\settings\lib\rhinoscript\object.py"
line 382, in MoveObject, "C:\Users\Aaron\AppData\Roaming\McNeel\Rhinoceros\5.0\Plug-ins\IronPython (814d908a-e25c-493d-97e9-ee3861957f49)\settings\lib\rhinoscript\object.py"
line 28, in script
Any help with understanding what's going on would be really helpful.
aaron…
how Honeybee Set EP Air Flow worked but apparently not as it still opens the window when T(out) > T(in) (I get positive heat gains in this case).
I basically want to use sensible natural cooling when possible and relevant, i.e. when the 2 following conditions are met :
T(in) > 28°C
T(out) < T(in)
I know this is possible in EP but I have the feeling it is not yet implemented in HB ? Any help would be greatly appreciated.
Best,
Aurelien…