quel que este interesado en aprender procesos Generativos y Paramétricos con Grasshopper para Rhino 5.
El Workshop esta organizado para que durante estos tres días, el estudiante domine los conceptos básicos y avanzados de Grasshopper.
Pre-requisitos:
Tener conocimiento del manejo de Rhino 5.
Cada estudiante debe traer su propio computador o portátil.
Rhino3D Colombia suministrara el Software de evaluación de Rhino 5 y Grasshopper.
Numero total de horas: 24
Fechas: Agosto 15, 16 y 17
Horas: de 8:00 am a 5 pm
Profesor: Andres Gonzalez, McNeel Miami
Lenguaje: Español / Ingles
Número de estudiantes: Máximo 8
Rhino Visual Tips 5.0 + SAVANNA3D
Se entregara un USB a cada participante con:
Rhino Visual Tips 5.0
Costos:
Antes del 2 de Agosto: 495.000 pesos Colombianos, después del 2 de Agosto, 595.000 pesos Colombianos.
Mayores informes:
www.Rhino3DColombia.com
Tel: 412 3015 Medellin, Colombia.
…
ich appears in the video is related to "set iterations number" in your example?
2. only works the first example in your GHX def... the other get crashed when compiling into mesh component take a look on the screenshot, maybe its problem with GH version? i'm usin 8.051
3. The sliders that controls the "# of iterations" it has range 0 to 99999 but on my computer it only works from 0 to 15 ... that's correct???
thank you in advance!
…
shopper and rhino files and tried messing with them to get a feel of the components. Now, in that file, the component ssiBeam is used, which I'm assuming is likened to the current version's ggSAPFrame? Now, in the old file, I went and created a section property with the new gg component and used it for the truss you had in there with no problems, but when I try to do the same thing for a file of mine that uses the ggSAPFrame component, the sections don't "extrude" right (for lack of a better way of putting it), and the section properties do not get baked into SAP when I use the ggSAPBake component (the element centerlines bake fine). Am i missing something here? Does the baking perhaps fail or go haywire if I don't have supports, or all elements of the structure baking at once (I started with just a few to try to get a feel for it). Any light you could shed on this would be great, thanks for all the help so far.
Matt…
ate the "base" ... load Rhino file fist.
2. This greatly reduced demo creates a Del Mesh "in real-time" (it's a very complex project that I'm after these days: 10 C# scripts work together to do ... something, he he) AND finds convex hull points as well, So it works "twice" but still is fast. In fact it's about 15 times faster than the very same thing that I did with Generative Components.
3. Again: NOT for your case but good fun (I believe). Obviously doing this for a couple of surfaces of yours ... it could yield also a real-time solution.…
- 100.
After that, I want to separate it into 5 different lists in spesific thickness.
in this case of 0-100 so it would be :
1. if the distance 0 - 20 then the thickness is 5
2. if the distance 21 - 40 then the thickness is 10
3. if the distance 41 - 60 then the thickness is 15
4. if the distance 61 - 80 then the thickness is 20
5. if the distance 81 - 100 then the thickness is 25
But, the problem is the list of distance isn't static between 0-100. It could be 5 - 250 / 3.5-175/etc.....
Could you help me how to make the expression?? Is this possible if I make one expression?
thank you.
Z.
nb: distance and thickness hasn't mathematical relation.…
Added by ZAQI FATHIS at 8:43am on November 27, 2013
Visiting School Rio de Janeiro will collaborate with the Centro Carioca de Design with the support of Columbia University Studio X to investigate new possibilities for the urban infrastructure surrounding World Cup Stadiums. Nation-wide, there has been significant investment to build and renovate stadiums for the 2014 World Cup in order to meet the required standard FIFA regulations (‘Padrão FIFA’). At the same time, there has been a large public demand for equal investment into transport systems, public space, and public programs such as hospitals and schools. The Visiting School will tap into the momentum of this movement, and promote a series of interventions within and around the World Cup structures, proposing new public programs and standards for their legacy. Students can choose to focus directly on the Maracanã stadium in Rio de Janeiro, the venue for the Final match of the World Cup. The intense ten-day workshop will employ computational design and digital fabrication to introduce a design methodology that creatively automates and promotes transformation, mutation and complexity for these infrastructure interventions.
Prominent Features of the workshop
Teaching teamThe teaching team will include a mix of tutors from the Architectural Association, including Theodore Sarantoglou Lalis e Dora Sweijd (lassa-architects.com) of Diploma 17, and locally-based architects, urban-designers and experts, mediated by locally-based Visiting School directors, to promote cutting-edge innovative strategies informed by local political, economic and construction issues.
Computational skillsThe workshop will teach advanced digital modeling and parametric design skills, no previous experience is needed. A group of specialist computation tutors will conduct an initial skills workshop and continue to assist throughout the workshop to develop the individual projects of the participants.
Digital FabricationA series of physical models will be built using digital fabrication techniques that will be taught during the workshop, no previous experience is needed.
Applications
1) You can make an application by completing the online application found under ‘Links and Downloads’ on the AA Visiting School page. If you are not able to make an online application, email visitingschool@aaschool.ac.uk for instructions to pay by bank transfer.
2) Once you complete the online application and make a full payment, you are registered to the programme. A CV or a portfolio is not required.
The deadline for applications is 11thApril 2014.
All participants travelling from abroad are responsible for securing any visa required, and are advised to contact their home embassy early. After payment of fees, the AA School can provide a letter confirming participation in the workshop.
Fees
The AA Visiting School requires a fee of £695 per participant, which includes a £60 Visiting membership fee.
Fees do not include flights or accommodation, but accommodation options can be advised. Students need to bring their own laptops, digital equipment and model making tools. Please ensure this equipment is covered by your own insurance as the AA takes no responsibility for items lost or stolen at the workshop.
Eligibility
The workshop is open to current architecture and design students, phd candidates and young professionals.
…
genetic algorithm requires a lot of iterative calculations, but the computing power needed for analyzing structural models is very huge, and it also takes much time. And modifying the structual model according to genetic algorithm was not so easy for real-scale complex structures.So, we've developed StrAuto, a parametric structural modeler and optimizer based on Rhino/Grasshopper. StrAuto can execute iterative structural analysis and optimization automatically, and the most powerful feature of it is that it can execute the analysis task (the most time consuming part of optimization) in multi-processed way on distributed systems in network.Now, in the movie you can see the galapagos G.A. optimizer in the left monitor (the main system) is running and many instances(15) of structural solver Sap2000 are running along with it. The middle monitor shows 5 worker systems that are running 3 instances of Sap2000 for each under the control of the main system.The number of sap instances can be extended as much as your SAP license permits.(one license can launch 3 instances of SAP)With StrAuto, structural G.A. optimization can be performed 10 ~ 30 times faster so that even very complex real scale structures can be optimized.If you are interested in StrAuto, you can see more athttp://tree8.chang-soft.co.kr/Sangsu Lee, changsoft I&I…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
TB of RAM. I think I'm going to start a GoFundMe campaign to buy one for myself :)
2- The server's cost is about $13 an hour. I get free access to supercomputer through my university and xsede.org because I earned an NSF Honorable mention last March, however, the supercomputers available through both resources are a little complicated for me to use, as opposed to the one available from amazon that has Microsoft server 2012 already installed.
3- I wanted to run 400 annual glare simulations for 400 different views.
4- I tried a to perform annual glare simulation for one view on my Dell XPS that has Intel Core i7-6700HQ processor and 16GB of system memory. The simulation took 2 hours to complete. Radiance parameter ab was set to 6.
5- I wanted to obtain the batch file for each view so I can run them on the server. So I used the fly component to run all 400 simulations and closed the cmd windows, that wasn't bad ( for me at least) because I asked my son to this job for me, he was just glad to help me :)
6- I created one batch file using this cmd command:
dir /s /b *.bat > runall.bat
This created a file with the path to each .bat file. I edited this file in Notepad++ to include the word "start" at the beginning of each line. This was done using the "find and replace" dialogue box.
7- I split my newly created batch file into 3 batch files, each one has about 130 file names and " start" before the file names.
8- installed radiance on my server
9- Ran the first batch file on the server, this started 130 cmd windows performing my simulations, CPU usage was anywhere between 90% to 100% and about 105 GB of RAMs were used.
10. It took about 5 hours to complete all 130 simulations, I expected to run all in 2 hours but can't complain because this would've taken about 260 hours to run on my laptop. After the simulations done I ran the second and then the third batch files ( total of about 15 hours).
11. I got 400 valid dgb files. Couldn't be happier!
…
nfusing.
Problem 01: the requested in-put of 'CroSecs' from 'OptiCroSec' component, based on introduction of itself, "a list of preferable structural thickness", and the algorithm will automatically find the sufficient number as the beam thickness. BUT, when I plugged 3 ranges, 1 to 15 CM, 2 to 15 CM, 5 to 15CM, the algorithm will always choose the finest number as the beam thickness, which turns out the beam thickness is, 1CM, 2CM, 5CM. 5CM in reality 'maybe' correct, but I just cannot image 1 and 2 CM beam will work. That`s very confusing.
Problem 02: the 'MaxDisp' from 'OptiCroSec' component, no matter how I slide the number, shape will remain still always. what is the fucntion of this input, should it be like a control to deformation of the shape?
Thanks in advance for any insight you can give!!
I attached 2 images to show the problem 01, and in the file rhino and gh, i marked out the problem part with red panels.
Best wishes,
Lei
…