be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
nother nurbs surface that is built from control points extracted from the other two (3 three rows of control points shown in the picture are the ones I would like to use).
When I try to use the "Surface from Points" component, however, I cannot get the surface to generate properly. From my understanding of previous discussions on this forum, the U parameter should be U+1 which in my case would be 11. No parameter from 0-11 is producing the results I'm looking for, however.
My attempted solution is attached. I get the feeling the solution will be quite straightforward...
Thanks,
Austin
…
al read” component in grasshopper.
But somehow it seems that the command line “TempSensor.requestTemperatures();” makes the firefly firmata somehow unstable. I have also connected 5 servo motor which move strangely irregular/wrong when the command line above is in the program. So, when I for example only control the "Digital Pin 12" in grasshopper it mainly moves the servo on Pin 11 (!) but also a bit time delayed the servo on Pin 12.
Do you have any ideas? It has to be something inside the “#include <DallasTemperature.h>” (Libary for the temperature sensor) which doesnt go together with the firefly firmata und gets something wrong in the "void WriteToPin" firmata command
Or do you may have any working codes for implementing a temperature sensor? Its doenst have to be the one i have, I could get another one.
here you can see the code: http://txt.do/drqao (a simplified version of the latest firmata including my TempSensor lines marked with "//...//TEST")
Thanks! Julian…
rights to register the "mapwingis.ocx" file.Francesco, would you be patient just a tiny little bit, so that we could try something else? I would be grateful if you could.
1) Close Grasshopper and Rhino2) Run the Revo Uninstaller Pro and uninstall your MapWinGIS application along with removing all the leftovers from the registry.3) Restart your PC, and once it boots again, make sure that you are logged in as an Adminstrator.4) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".5) Turn off your Antivirus, which ever it is.6) Download the 64 bit version of v4.9.4.2 MapWinGIS.7) Right click on downloaded MapWinGIS-only-v4.9.4.2-x64.exe file, and choose "Properties". If there is "Unblock" button click on it, and then click on "OK". If there is no "Unblock" button, just click on "OK".8) Left double click on MapWinGIS-only-v4.9.4.2-x64.exe file and install it to "C:\dev\MapWinGIS" folder. Choose "Full installation" during installation process!9) In your Start menu's search box type: "CMD". Once the "Command prompt" appears do not left click on it! Instead right click on it, and choose "Run as Administrator".10) A command prompt window will open. Type the following command:
"your_regsvr32_folder_path\regsvr32.exe" /u /s c:\dev\mapwingis\mapwingis.ocx
If command does not result in an error message, then type this one afterwards:
"your_regsvr32_folder_path\regsvr32.exe" /s c:\dev\mapwingis\mapwingis.ocx
11) If no error appeared again, then open your Rhino and Grasshopper and check what Gismo_Gismo component prints from its "readMe!" output.If errors appeared, it would be nice if you could post their screenshots.…
Added by djordje to Gismo at 5:46am on March 27, 2017
R Light Studio - Georg Sochurek Schnelle Beleuchtungsoptimierung mit HDR Light Studio: HDRI-Environment-Maps in Echtzeit ganz einfach erstellen und bearbeiten 10:45 - 11:45: C4D und Adobe Photoshop - Christoph Schindelar Prototyping für einen Wintersportartikel-Hersteller mit Cinema 4D 12:00 - 13:00: Autodesk 3ds max - Daniel Daghofer Software für 3D-Modellierung und Animation 13:30 - 13:30 Pause 13:30 - 14:30: MODO - Mathias Zellerhof Produktdesign leicht gemacht - mit modo 701 von TheFoundry 14:45 - 15:45: Rhino 5 - Dipl. Ing. Fabio Palvelli Advanced NURBS-Modelling mit Rhino 5 für Designer und Architekten 16:00 - 17:00: Autodesk Maya - David Wuchte Umfassende 3D-Animationssoftware 17:15 - 18:15: 3D Coat - Christoph Schindelar Feinmodellierung (Sculpting) & Design von Handy-Designelementen mit 3D Coat Zusätzlich haben Sie die Möglichkeit in den Pausen / im Anschluß div. Hardware zu testen / anzusehen: Monitore: CG Serie von EIZO (inkl. Swing Sensor/Colorimeter) EIZO Foris mit EIZO Spyder EIZO Touchscreen NEC Spectraview Reference inkl. X-Rite Colorimeter Stiftdisplays: WACOM Cintiqs 3D Mäuse: SpaceMouse Pro SpacePilot Pro…
y retículas aprenderás a modelar parametricamente con Rhinoceros + Grasshopper para aplicarlo a la manufactura digital en láser y/o CNC. El taller se desarrolla a lo largo de 5 clases y una presentación donde los talleristas presentarán una pieza cortada con láser o CNC.
LOS PRECIOS SON EN DOLARES. OFRECEMOS PAQUETES CON EL TALLER Y LA LICENCIA DE RHINO COMERCIAL Y EDUCACIONAL…
right? When the dataTree is this simple its not really a problem, but when it grows and I want to be able to refer to a specific GH branch e.g. {11;320} and I need to read this specific branch in Python? How do I do this?
I know that there is the function tree.Path(x) this will give me the GH Path, but how do I figure out what x needs to be? I guess there must be a simple answer :).
Thanks Rasmus…
Added by Rasmus Holst at 1:24am on October 14, 2013
eroberfläche des Grasshopper Programms
Funktionsprinzip eines grafischen Algorithmus-Editors (Datenfluss)
Unterscheidung von Parametern (Datentypen) und Komponenten (Datenverarbeitung)
Erzeugung, Bearbeitung und Analyse von Geometrie-Typen: Punkte, Vektoren, Linien, Kurven, Flächen (surfaces, brep) und Netze (meshes)
Strukturierung der Daten anhand von Listen und Bäumen
unterschiedliche Verknüpfungsmöglichkeiten von Parametern (data matching)
praxisnahe Grundlagen der Geometrie und Vektorrechnung für generatives Design
effizienter Aufbau von parametrischen Modellen anhand Übungsaufgaben
Auszug von Daten aus Modellen für die Fertigung; Daten aus Tabellen (Excel, CSV) importieren, exportieren
Einsatz von benutzerdefinierten Komponenten (custom components)
Vorkenntnisse: Rhinoceros3d Benutzeroberfläche der Software: Englisch Unterrichtssprache: Deutsch
Details und Anmeldung:
www.vhs-sha.de
click: SUCHE
Kurstitel: GRASSHOPPER
oder direkt:
http://www.vhs-sha.de/index.php?id=90&kathaupt=11&knr=3151053&kursname=Grasshopper+I
Trainer: Peter Mehrtens
Kursdauer: 3 Tage / 8 Stunden pro Tag
Freitag, 19.07.2013, 08:00-17:00 Uhr Samstag, 20.07.2013, 08:00-17:00 Uhr Sonntag, 21.07.2013, 08:00-17:00 Uhr Ort: Volkshochschule Schwäbisch Hall, im Haus der Bildung
Teilnahmegebühr: 349,00 € Teilnehmerzahl: 4-10 Personen
…
ated in all editions of Architektura Parametryczna Workshops!Architektura Parametryczna Workshops Optimization Warsaw 2016 FAQWHEN?21-22nd May 2016 (Saturday-Sunday)HOW LONG DO THE WORKHSOPS LAST?The workshops last in total 16 hours.Saturday 10AM -7PM (with lunch break), Sunday 10AM -7PM (with lunch break)WHAT WILL I LEARN?On Saturday the optimization processes with solar, views and structural analysis will be explored. We will be discovering optimal solutions with the help of plug-ins such as Galapagos, Silvereye, Octopus, Karamba and Ladybug. In the Sunday morning we will learn how to present the results of the optimization: creating catalogues of solutions and printing the optimization graphs. In the afternoon participants will have time for the development of the personal project. HOW MUCH DOES IT COST?The workshops cost 600 PLN (or 160€) for Early Bird payments and 700 PLN (or 190€) for the regular payments. The 3-person group - 1500 PLN (or 440€ )EARLY BIRD?For those who are certain that they will attend the workshops, we have a special Early Bird offer till 30th of April 2016.HOW CAN I SIGN UP?Send an email to info@architekturaparametryczna.pl with the title: “OPTI WAW 16”.HOW MANY PLACES ARE AVAILABLE?We have only 11 places!WORKSHOPS: Level: intermediate – advancePerquisites: the basic knowledge of Rhino and Grasshopper3D. Plug-ins: Silvereye, Octopus, Ladybug, Karamba. Weaverbird. Python GHThe main aim of the 16-hour workshops is to give the participants the understanding of how the optimization process can be used in practice and how it can help in solving everyday design problems. The practical exercise will be supported with the short lectures explaining the theoretical background of the optimization algorithms. The general program of the Optimization Warsaw 2016 Workshops*:1. Optimization of the facade geometry with solar analysis.2. Optimization of the roof structures with Karamba.3. Finding the optimal configuration of the space frame structures with Karamba.4. Discovering the best location or/and geometry of the building in accordance to the best views from the plot.5. Presentation of the discovered solutions. *Some of the exercises might be changed.…