ells new products like the Firefly Interactive Prototyping Shield which mounts on top of your Arduino Uno and provides access to a number of useful input (ie. sensors) and output (ie. motors) devices. It includes features like:
Three linear slide potentiometers connected to analog pins 0, 1, and 2
Two-axis joystick connected to analog pins 3 and 4
Light sensor (photocell) connected to analog pin 5
Three push buttons connected to digital pins 2, 4, and 7
Red LED connected to digital pin 13
RGB LED connected to digital pins 3, 5, and 6
Two servo connections on digital pins 8 and 9
A connection to the Easy Stepper Driver (co-designed by Sparkfun Electronics and Brian Schmalz) to control stepper motors. The direction of the motor is controlled through digital pin 10 and the number of steps through digital pin 12
High-voltage MOSFET circuit capable of driving lights, valves, DC motors, solenoids, or anything else requiring higher voltage or current. The gate of the MOSFET is connected to digital pin 11 (PWM).
Some come take a look and let us know what you think!
…
ed according to list C.
I tried replace members, but it consists of geometry, so it doesn't worked.
In list C I filtered all the indices that need to be replaced.
All items in {0;0} from C need to be replaced by List B {0;0}
All items in {0;1} from C need to be replaced by List B {0;1}
And so on...
In the end everything needs to be fed into a orient component.
G is the geometry behind list B
A is the new list (but I don't know how to create)
B is the list A of all 60 panels
To wrap up the question:
I need to have entry 1 from list B in a new list on position: 0 1 2 3 5 6 7 10 11 12 15 16 21
I need to have entry 2 from list B in the same new list on position: 4 8 9 13 14 etc. etc. etc.
I wonder how I can do this :) Thanks in advance!
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
he default for Rhino, degree=5 gives you smoother curves, but each control point matters less, degree=11 is the highest degree Rhino allows. Apart from 2, degrees tend to be odd rather than even, though Rhino supports both.
In addition to the degree and the control points, Nurbs curves have knots. A single knot is just a number, and the list of all knots is called the knot-vector of a curve. The number of knots depends on both the degree and the control-point count, and the spacing of the knots affects the shape of the curve a little bit. If there are <degree> knots with the same value, then the curve is somewhat discontinuous at that location which could manifest itself as a kink or as a clamped end-point. However it is not possible by just looking at the shape of a curve to say where stacked knots might be, but you can use the Rhino _List command to inspect all details of a Nurbs curve.…
I've attached a rh and ghx file. http://we.tl/ghsd0UTxji - wetransfer link. I'm guessing the trick is to correctly define the Range (R) / Domain in the Random component, so that the circles' radi can vary between the fixed and static domain of 10 or 12 or 14 or 18 or 20. Meaning that the radi can only be 10, 12, 14, 18 or 20 - and not, lets say.. 11, 13, 15, 16, 17 or 19 for that matter. Thanks in advance, i hope someone can figure it out, because i can't seem to find anything online about how to set up such as specific domain.
…
(18, 11, 0, 17), also put in the assembly component.
How can I know which value of the reaction forces correspond to which support?
In the manual is stated that when the reaction force component is used, than the values are displayed in ascending sequence of the corresponding nodes.So if I input the support nodes like thispoint with index 18point with index 11point with index 0point with index 17are the reaction forces displayed like this (per loadcase)?0 - reaction forces in point with index 01 - reaction forces in point with index 112 - reaction forces in point with index 183 - reaction forces in point with index 17
Thanks!
BestLara…
onsecutive points at the same height then your 'Break at discontinuities' component eliminates the middle point completely and then the 'Interpolate Curve' component gives a much bigger bump in the wrong direction. This was enough to get curves to meet from opposite sides.
I fixed this by changing the heights to 1.1 or 2.9, rather than 1.0 and 3.0, but it took a little while to work it out! Sigh.
I attach a new version. But I actually preferred it as it was before. See what you think!
Bob
p.s. in the first list, elements 11, 12, 23 and 24 go from 1 to 3; elements 17 and 18 go from 3 to 1. In the second list, elements 6, 17, 18 and 29 go from 1 to 3; elements 12 and 23 go from 3 to 1. Given the above fix, these can be easily seen.…
Added by Bob Mackay at 10:40pm on November 24, 2015
you post a screenshot of what the message coming from its readMe! output looks like?2) Close your Grasshopper and Rhino.3) Download "Revo Uninstaller Pro" from here. It is free for first 30 days, which is what we need.4) Right click on the RevoUninProSetup.exe and check if the file is blocked. If it is, unblock it.5) Run the RevoUninProSetup.exe file and install "Revo Uninstaller Pro".6) Uninstall "MapWinGIS" with "Revo Uninstaller Pro". It is important that "Revo Uninstaller Pro" deletes not only files from MapWinGIS installation folder, but also all other leftovers (as registry inputs). Here is a small tutorial on how to do that. Watch it from 6:10 till the end.7) Restart your PC8) When your Windows boots up, make sure that you are logged in as Administrator!9) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".10) Turn off your Windows Firewall.11) Then turn off your custom Firewall (in case you have another one, besides standard Windows Firewall).12) Completely turn off your Antivirus.13) Download again the MapWinGIS-only-v4.9.4.2-x64.exe.exe file from here.14) Right click on the MapWinGIS-only-v4.9.4.2-x64.exe file and see if it is blocked. If it is, unblock it.15) Right click on MapWinGIS-only-v4.9.4.2-x64.exe file and choose: "Run as"... Administrator.16) One the installation preparation steps start, choose "Full installation". Wait for the MapWinGIS installation to finish.17) Right-click on "Rhino 5" icon and then choose: "Run as administrator".18) Open the the ironpython_admin.gh file again, and again post a screenshot of the message coming from its readMe! output.19) Drop the "Gismo Gismo" component to Grasshopper canvas. Post a screenshot of the message coming out from its readMe! output.
So we will need in total three screenshots of the readMe! output messages.
Thank you once again for being patient, and sorry for the large number of steps.…
Added by djordje to Gismo at 1:52am on April 9, 2017