eone would know how to group each data position from each branch ... meaning, for instance, that I have a list of data with 3 branches, each branch containing 28 data instances (see attached image). Now, how would I get the (0;0)+(1;0)+(2;0) to be grouped in a new branch, as well as (0;1)+(1;1)+(2;1) and so on?
Also, I need for the setup to able to take in variables, so that the 3 branches might change to 6, and the 28 data instances might to change to anything between 10 and 100.
Thanks in advance,
/Claus
…
error message when GH starts loading (almost the last stage of loading).
I un-installed and re-installed it, but still the same error. When I checked the plug-ins in the options, it seems that it is loading the right one (from the file path), but I noticed when GH starts loading, it is loading GH version Sep 28, 2012.
Any idea how I can get around this problem?
thanks
…
ay be loading it from Rhino 4, but even when I un-installed GH for Rhino 4, GH rhino 5 still loading that version. The strange thing is that when I check Tools-options-plug ins, GH -properties it shows the right file name and path of GrasshopperPlugIn.rhp, and the right registry path too that is in Rhino 5 Plug ins. So why on earth it is loading that previous mysterious copy?, and where it can be located?
Any steps I need to follow that may solve the problem?…
Added by Zayad Motlib at 12:02am on March 11, 2013
are not copy with the number that belong to each other, like:
untrimmed surface0 should be 41 pieces
untrimmed surface1 should be 28 pieces
untrimmed surface1 should be 21 pieces
it result like this
exclude the 1st and 2nd pieces,the others all is untrimmed surface 1
and the attachments is the result that i want, I done it one by one.…
Mmm really nice post. Usually light electronic Trip Hop, or spanish Hip-Hop.
Portishead
Radiohead
Massive Attack
Propellerhead
SFDK
Juaninacka
Tote King
Best Regards ;)
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
p;biw=1680&bih=925&tbm=isch&tbnid=UQXK-STjeJrGhM:&imgrefurl=http://www.grasshopper3d.com/forum/topics/sinusoidal-facade&docid=XRgBzjBowOStWM&imgurl=http://storage.ning.com/topology/rest/1.0/file/get/2768634805?profile=original&w=1805&h=727&ei=itp3UbHLCvDs0gWy-oGQCA&zoom=1&ved=1t:3588,r:0,s:0,i:80&iact=rc&dur=487&page=1&tbnh=141&tbnw=340&start=0&ndsp=28&tx=217&ty=36
But somehow, it doesn't seem to work when i do the same.. does anyone know why?
Regards, Rutger…
iders that control the total amount ( U&V) and the branches are formed by picking i.e the U and the points will then be the number on the V slider...
I realize that this question may have been asked before, but I cannot solve it with the path mapper and it seems so easy
M…
byte-accuracy red, green, blue channels) = 27 bytes. More likely 28 bytes as colours are probably stored as 32-bit integers, allowing for an unused alpha channel.
28 * 800,000 equals roughly 22 megabytes, which is way down from 9 gigabytes. That's a 400 fold memory overhead, which is pretty hefty.
Grasshopper stores points as instances of classes, so on 64-bit systems it actually takes 64+64+3*8 = 152 bytes per point*, which adds up to 122MB, still way less than 9GB. It would be interesting to know where all the memory goes...
* Grasshopper points also store reference data, in case they come from the Rhino document. This data will not exist, but even so it will require 64-bits of storage.…
Added by David Rutten at 4:13pm on December 11, 2014