e: {55,B}(2)
Directly applying a brep-curve intersection does not work. I need to match the structures before by "trimming" one level in the big datastructure and "matching" it afterwards. or "repeating" the brep datastructre but I suspect there must be an easier way... how would you do this?
data_matching.gh
…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
. From the Thermal Comfort Indices component, Comfort Index 11 (TCI-11):MRT = f(Ta, Tground, Rprim, e)
with:- Ta = DryBulbTemperature coming from ImportEPW component- Tground = f(Ta, N) where N comes from totalSkyCover input. Tground influences the long-wave radiation emitted by the ground in the MRT calculation.- Rprim defined as solar radiation absorbed by nude man = f(Kglob, hS1, ac)- ac is the clothingAlbedo in % (bodyCharacteristics input)- I can't find any definition in the code of Kglob and hS1. Could you tell me please what are those values referencered to? --> probably the globalHorizontalRadiation but how?- e = vapour pressure calculated from Ta and Relative Humidity input
Do you agree that in this case the MRT does not depend on these inputs: location, meanRadiantTemperature, dewPointTemperature and wind speed?It does not depend neither on the other bodyCharacteristics like bodyPosture, age, sex, met, activityDuration...?
MRT calculated by the TCI-11 method is the mean radiant temperature of a vector pointing vertically with a sky view factor of 100%?For ParisOrly epw,
2. From the SolarAdjustedTemperature component (that seems to be more used for the UTCI calculation examples on Hydra compared to TCI-11).
In contrast to the TCI-11, this component distinguishes diffuse and direct radiation and contextualizes the calculation thanks to _ContextShading input, right? It can also be applied to a mannequin thanks to the CumSkyMatrix and thus evaluate the dishomogeneity of radiation exposure.This component seems not to consider the influence of vapour pressure on the result --> is it then more precise to put the MRT output (from the TCI) as an input of meanRadTemperature for SolarAdjustedTemperature?The default groundReflectivity is set to 0.25 --> is GroundReflectivity taken into account in the Tground or MRT calculation in the TCI component? If yes, what is the hypothesised groundReflectivity?The default clothing albedo of 37% (TCI-11 bodyCharacteristics) corresponds to Clothing Absorptivity of 63%?
If the CumSkyMatrix input is not supplied, I get 9 results for the mannequin --> where are those points/results coming from?
If the CumSkyMatrix input is supplied,I suppose the calculation of the 482 results correspond to a calculation method similar to the radiation analysis component that is averaged over the analysis period. Right?But I don't understand why the mannequin is composed of 481 faces and meshFaceResult gives 482 results.
Finally, what is the link between the MESH results, the solarAdjustedMRT and the Effective Radiant field ? Is there a paper to have a detailed explanation of the method?
3. Here are some results for the ParisOrly energyplus weather data. You can find here attached the grasshopper definition.There is no shading in this simulation and the result coming from the ThermalComfort indices for MRT is very different compared to the solar adjusted MRT.Why such a big difference and which of the result should be plugged into the UTCI calculation component?
Results for ParisOrly.epwM,D,H:1,1,12
Ta : 6.5°Crh: 100%globalHorizontalRadiation: 54 Wh/m2totalSkyCover: 10MRT (TCI-11): 1.2°C
_CumSkyMtxOrDirNormRad = directNormalRadiation : 0 Wh/m2diffuseHorizontalRad: 54 Wh/m2_meanRadTemp = TasolarAdjustedMRT: 10.64°CMRTDelta: 4.14°C
_CumSkyMtxOrDirNormRad = CumulativeSkyMtxdiffuseHorizontalRad: 54 Wh/m2_meanRadTemp = TasolarAdjustedMRT: 10.47°CMRTDelta: 3.97°C
_CumSkyMtxOrDirNormRad = CumulativeSkyMtxdiffuseHorizontalRad: 54 Wh/m2_meanRadTemp = MRT (TCI-11)solarAdjustedMRT: 5.17°CMRTDelta: 3.97°C
Thanks a lot for your helpRegards,
Aymeric
…
cause you are not saying what you want inside the second tree. You say this is not important, ok... then just take the first tree as it is and there you have it! Two trees with the same structure!....
Of course I am guessing the above answer will not satisfy you, so let's take it in your case:
You want to move 1458 lines on Z axis.
The question is: How high do you want to move each line?
A. You want to move them all 1 unit high? then do this:
B. You want to move eash of the 54 lines of every list by the corresponding 54 Y values? Then do this:
C. You want to do tha same as (B) but with the 2 trees having the exact same structure? There is absolutely no point in that but if you are obsessed about it you could do this:
What I am trying to say is that the structure of a tree is irelevant if you don't know what you want to have inside it.
And the method to create a tree with the desired structure depends again on what you want to have inside the tree....…
nowledge, tools, materials and machines. The Clusters provide a focus for workshop participants working together within a common framework.
Clusters provide a forum for the exchange of ideas, processes and techniques and act as a catalyst for design resolution. The Workshop is made up of ten Clusters that respond in diverse ways to the sg2012 Challenge Material Intensities. The Call for Clusters is now open to proposals which respond in innovative ways to this year's challenge.
Deadline: September 19 2011
More information can be found here:
http://smartgeometry.org/index.php?option=com_content&view=article&id=129&Itemid=146
sg2012 takes place from 19-24 March 2012 at EMPAC (http://empac.rpi.edu/) and is hosted by Rensselaer Polytechnic Institute in Troy, upstate New York USA. The Workshop and Conference will be a gathering of the global community of innovators and pioneers in the fields of architecture, design and engineering.
The event will be in two parts: a four day Workshop 19-22 March, and a public conference beginning with Talkshop 23 March, followed by a Symposium 24 March. The event follows the format of the highly successful preceding events sg2010 Barcelona and sg2011 Copenhagen.
sg2012 Challenge Material Intensities
Simulation, Energy, Environment
Imagine the design space of architecture was no longer at the scale of rooms, walls and atria, but that of cells, grains and vapour droplets. Rather than the flow of people, services, or construction schedules, the focus becomes the flow of light, vapour, molecular vibrations and growth schedules: design from the inside out.
The sg2012 challenge, Material Intensities, is intended to dissolve our notion of the built environment as inert constructions enclosing physically sealed spaces. Spaces and boundaries are abundant with vibration, fluctuating intensities, shifting gradients and flows. The materials that define them are in a continual state of becoming: a dance of energy and information.Material potential is defined by multiple properties: acoustical, chemical, electrical, environmental, magnetic, manufacturing, mechanical, optical, radiological, sensorial, and thermal. The challenge for sg2012 Material Intensities is to consider material economy when creating environments, micro-climates and contexts congenial for social interaction, activities and organisation. This challenge calls for design innovation and dialogue between disciplines and responsibilities.sg2010 Working Prototypes strove to emancipate digital design from the hard drive by moving from the virtual to the actual in wrestling with the tangible world of physical fabrication. sg2011 Building the Invisible focused on informing digital design with real world data. sg2012 Material Intensities strives to energise our digital prototypes and infuse them with material behaviour. They have the potential to become rich simulations informed by the material dynamics, chemical composition, energy flows, force fields and environmental conditions that feed back into the design process.
More information can be found at http://www.smartgeometry.org…
思った感じになりません。
balls の代わりにplanarカーブを直接入れてみましたがエラーが出ます。
ファンクションにしてみたところ、forループので作った数値が反映されていません。
ファンクションのインスタンス?を出力していないと思い上記のようにしましたがエラーが出てしまいます。
以上の事から自分の認識が正しいのかよくわからなくなりました・・・
python自体の深いところをわかっているわけではないので余計こんがらがりました。
そこで、for b in ballsはどのような条件または使い方であれば使えるのでしょうか?
そして、上記のように別のオブジェクトに対しての使い方はどのようにすればできるのでしょうか?
2:同じファンクション内のdist = rs.Distance(self.pos,b.pos)についてですが
この文章も for b in balls によってbはBallのインスタンスであると定義?されたためb.posがbの位置であると分かるのでしょうか?
pythonは定義しなくても動いてしまうのでどのような時に使えるのか文章見ただけではよくわかりません・・・
大変細かいことかもしれませんが、よりpythonをしっかりと理解するためにも、どなたかわかる方ご教授いただけると幸いです。…