se presentarán una pieza cortada con láser o CNC.Extracto de TemarioIntroducción Fundamentos Grasshopper Image Sampler V-Ray Interiores Que es es CNCFundamentos Interfase Visualización - Grasshopper V-Ray Exteriores Arboles de datos Corte, Laser e impresión 3dTeoria de Curvas Componentes y parametros Listas de datos V-Ray Materiales Clusters ToleranciasTranspocición Vectores y reticulas -Atractores Series y rangos Teoria de Superficies Conexiones Estrategias de modelado para manufacturaSimetrias Transpocisión parametrica Formulas Panelizacion Teoría de Ensambles Teoría de archivos para corteAtractores Cull Random Información del taller:Fechas: del 8 al 26 de Junio de 2015Sesiones: 8 de 3 hrs y presentación finalDuración: 27 hrs.Días: Lunes,Miércoles y ViernesHorario: de 19:00 a 22:00 hrsPrecio : $4,500 Apartado: $2,000Pago oportuno (antes del 1 de Junio): $3,500PAQUETESTaller y Rhino 5.0 Educativa: $6,500.00 Taller y Rhino 5.0 Comercial: $21,000.00 *Sólo hacemos reembolso en cancelaciones con un mínimo de 15 días previos al taller.info@dimensiontallerdigital.comtel oficina (55) 50160634…
(u) direction is easy enough, and I want to extract the curves frmo the (v) direction and have both sets come from the same point grid.
I want to rearrange the list structure of the SDivide component such that
1(0,1,2,3,4...)
2(0,1,2,3,4...)
3(0,1,2,3,4...)
becomes
1(0,0,0,0...)
2(1,1,1,1...)
3(2,2,2,2...)
I have been using the List Item component to achieve basically the same effect but repeating it over and over for 27 lists gets really tedious. Thanks if anyone can point me in the right direction
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
tting-edge results at the interface of geometry processing and architectural design. Scientific chairs of the conference are Lars Hesselgren, Shrikant Sharma, and Johannes Wallner. Keynote speakers are: Pierre Alliez, INRIA Sophia-Antipolis Philip Ball, Physicist and science writer Chuck Hoberman, Hoberman Associates Jan Knippers, Knippers Helbig Advanced Engineering
We are happy to announce that public lectures will be held by Toyo Ito and Mutsuro Sasaki. The organization is cordially inviting you to contribute a paper or a workshop, or simply to visit. More details concerning registration and submission can be found on the conference web page at http://aag12.architecturalgeometry.at/. The submission deadline has recently been extended.
This conference receives funding from the ECs Seventh Framework Programme under grant agreement number 230520. Thanks to this funding we are able to cover the registration fees and support the travel expenses of 20 young participants. Places will be distributed among those who submit a poster, paper or workshop proposal.…
掌握编程过程中遇到的思路方面和技术方面的问题. 内容包括以下几个方面:
反向逻辑思维能力的培养;
建立清晰的编程逻辑思维能力;
GH 的程序设计理念;
并行数据结构深入理解和控制.
Grasshopper course of McNeel Asia focus on the cultivation of students flexible use of programming techniques, the ability to solve practical problems. Our course deep into the whole process of programming, from programming thinking model, the components principle to usage details do detailed explanation, help students complete mastery programming encountered in the process of thinking and technical aspects, include the following content:
Ability of reverse logical thinking;
Establishment of clear programming logical thinking ability;
The program design concept of Grasshopper;
Understanding parallel data tree structure and how to control it.
更多详细内容... More details…
授课讲师 Instructor 课程由Grasshopper原厂McNeel公司在中国地区的两位 Rhino 原厂技术推广工程师 – Dixon、Jessesn联合授课。课程结束后对达到授课预定目标的学员颁发唯一由Grasshopper原厂认证的结业证书.
Dixon & Jessesn, McNeel Asia Support engineer, by the end of course student who achieve the intended target will get the authentication certificate from McNeel Asia.
课程报名 Register this course 课程即日开始报名, 开课一周前停止报名, 名额满提前报名结束. This course begin to sign up, stop sign up a week ago, with the quota ahead over.
在线报名参加课程...
Sign up to this course…
课程日期 Schedule 7/15-7/20 Beijing 北京 7/26-7/31 Shanghai 上海 7/07-7/12 Shenzhen 深圳
课程范例演示 Samples of Grasshopper course demo
Note: pls follow below comments by Jessesn to see the samples…
industrial design.
We will cover from basic Rhinoceros commute workshop for CAD users, advanced rendering illumination strategies with Vray for Rhino, etc., to advanced grasshopper and other plugins (like geco) workshops focused in complex and parametric design.
Workshop schedule: 2 days 16h workshop (10-14h & 15-19h)
Language: Spanish(*).
*We are planning to make two other workshops in English at Vilnius, Lithuania in mid July (from 11th to 28th). If you are interested please contact me.…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
this common installation problem please find a tested remedy shared by one of the group members:
Comment by Iman Sheikhansari on August 26, 2019 at 8:33amDelete Comment
HiIf you are encountering a problem with rhino 6 versions don't worryFollow these steps.1. Download SYNTACTIC from https://sites.google.com/site/pirouznourian/syntactic-design2. Install it and go to the installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin
I hope this helps,
Best regards,
Pirouz
…