} (N=11) {0;1} (N=11) {0;2}(N = 11) {0;3}(N = 11) {0;4}(N = 11)
2. I run the Points that are coming out from the Divide Curve Components through the Path Mapper components with this definition:
{A;B} (i) > {A} (i)
3. I run data coming out from Path Mapper component through:
a) Parameter Viewer component and the result is:
{0} N=11 (data with 1 branches)
b) Point > Panel and the result is:
collection of 11 point (N=11) which is the exactly the same as the collection of point belonging to {0;4} (N = 11).
So, here is the question:
why the collection of points coming out from the Path Mapper {A;B} (i) > {A} (i) component is the same as the collection of points belonging to the curve {0;4}(N = 11) ?
Anyway ... It 's the first time I ask a question here... so I would like to thank you for what you do with your work! Thank you! You are really great!…
output will show a tree with 3 branches of 4 integers each that I can pass on to other components. What is the best way to do it?
I have tried creating a tree and using a for loop to do so, but it didn't work.
Thank you for your help.
…
First use a series component with start=1, step=42, count=3
Use the output to create a new series component with start=existingseries, step=1, count=11
e
7. True
8. True <-- this one
9. True
10. False
11. True
12. False
13. True
14. True <-- this one
15. True
16. False
17. True
18. False
19. True
20. True <-- this one
21. True
22. False
23. True
24. False
25. True
26. True <-- this one
27. True
28. False
29. True
30. False
31. True
32. True <-- this one
33. True
Any idea how I can solve this?
Thanks!…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…