ersect (2, 3, 4, 5, 6) with the line and the ones which do not intersect (0, 1, 7). Intersect is done! But how to get the non intersecting vectors (0, 1, 7)?
So I e. g. could deselect vectors 2, 3, 4, 5, 6 so I would display/use only vectors 0, 1, 7 and the bounced ones.
Appreciate your help!
Rudi…
ea being the further up the column, the more dramatic the effect. For example:at 1", the effect is at 1at 3", the effect is at 3at 7", the affect is at 7, ect.I figure it must be some form of formula, but I am uncertain how to call upon other number sliders, or how to set it up.Thanks!…
terior wall. I disconnected this air wall and the model runs fine I ran it for 19 generations for over the period of 7 hours.
2. Earlier, when I ran the model with air wall connected to altConstruction_, I observed that in the middle of this optimization process, one or many zones will disappear altogether from rhino scene and that is when the results became undefined. In the image you attached, if you see in the top left corner, zone Commercial 1F is missing. I witnessed a similar behavior. This disappearance of zones may explain the erratic highs and lows in fitness numbers that you are talking about.
3. I also made a few changes in how you apply glazing ratios. Please find file with changes.
4. My results are attached as well. When I used air wall as altConstruction, the model ran for 7 generations and then started displaying errors as I mentioned in my earlier responses. After removing air wall and making a change in how glazing ratio is applied, the model ran successfully for 19 generations.
Hope this helps,
Devang
…
This must be a bug because its true for dividing by all odd numbers:
(i-1)/3
(i-2)/5
(i-3)/7
(i-4)/9
(i-5)/11
....
(i-n)/2n+1
And you can't make it work for even numbers
Added by Danny Boyes at 5:06pm on January 13, 2010
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…