I extract the first two with a "Redim Preserve t(1)" command.
In the first case, the redim is correct, Line 7 = Line 2 and Line 8 = Line 3. It just kept the first two values like it is supposed to be.
But, for the second curve starting Line 9, some t values are messed up after the Redim. Line 16 = Line 17 despite Line 11 was different from Line 12. That's what is creating a problem later in the Split.
Weird.
…
number of divisions on that curve as in the defintion (i.e. by 4). The offset in the def is slightly different and should cull two or three more curves as in the lists that show my aim below.
Basically I want to look into each branch of the groups of points from each closed curve . Marking in a list whether it contains a one or a zero (0= outside 1 = coincidents).
{0;0}0. 21. 22. 23. 2 {0;1} 0. 01. 22. 03. 2 {0;2}0. 01. 02. 03. 0 {0;3}0. 21. 22. 23. 2 {0;4}0. 21. 22. 23. 2 {0;5}0. 21. 22. 23. 2 {0;6}0. 01. 22. 23. 1 {0;7}0. 21. 22. 03. 0 {0;8}0. 21. 22. 23. 2 {0;9}0. 21. 22. 23. 2 {0;10}0. 21. 22. 23. 2 {0;11}0. 21. 22. 23. 2 {0;12}0. 21. 22. 23. 2 {0;13}0. 01. 22. 23. 0 {0;14}0. 21. 22. 23. 2
I want to create a list from these points. That marks each curve that pokes out, in a cull pattern as such:
20022210222202
Using a 1 where there are co-incidents in the curve points and the boundary. A 2 for true (outside points) and a 0 for containment. So I might be able to use the 1 in future developments - however if a true false list is easiest I can live with that.
So could I use F(x) function? - to look for 0 or 1's in each bunch of points and thus list as such for a cull pattern? or will Path mapper help me here? Or can I rely on simply grafting and splitting??
I am usure of the neatest solution and would love to learn. Hope you can direct me.rgrds
J.…
sinergetici associati alla compresenza simultanea di differenti strumenti di analisi e digital design all'interno di un processo di progettazione in svolgimento. I partecipanti utilizzeranno Grasshopper (modellatore parametrico per Rhino): l'uso di questo editor grafico di algoritmi si integra alla perfezione con gli strumenti di modellazione di Rhinoceros 3D espandendo le possibilità di corstruire modelli parametrici altamente complessi. Per generare una complessità simile saranno utilizzati collegamenti live ai diversi programmi elencati di seguito: . Autodesk Ecotect Analysis via GECO . FEA software GSA via SSI Durante questi intensi 3 giorni, i partecipanti impareranno il workflow dei plug-ins con l'aiuto di esempi esplorando una panoramica dei differenti software, le possibilità di testare le performances di un progetto o l'uso di strumenti addizionali non legati ad un singolo sistema (es. accentuazione, formazione, reazione parametrica) [english text] The focus of the workshop is to integrate and correlate the synergistic effect associated with simultaneous presence of different digital design- and analysis tools in an ongoing design process. The main attention is set on easy to handle interface , which should be used at a early stage of conceptual design to respond to external and internal influences in a intelligent and sustainable way. Participants will use the software Grasshopper as a parametric modeling plug-in for Rhino. The usage of this graphical algorithm editor tightly integrated with Rhino's 3-D modeling tools open up the possibility to construct highly parametrical complex models. To generate this complexity we will use live linkages to several programs listed below: . Autodesk Ecotect Analysis via GECO . FEA software GSA via SSI In this 3 intense days, the participants should learn the workflow of the plug-ins with the help of examples and get an overview of the different software's, there possibilities for evaluating the performance of a design or the usage of additional tools to be not chained to a single system . (e.g. parametrical accentuation, parametrical formation, parametrical reaction) [.] Dettagli : Istruttori: Thomas Grabner & Ursula Frick from [uto]. lingua del corso: inglese (saranno disponibili tutor di supporto ma è richiesta una conoscenza di base della lingua unglese).
Quote d'iscrizione (min 12 max 20 posti): educational* : € 280.00 + iva professional: € 450.00 + iva * studenti, docenti, ricercatori, dottorandi e laureati fino a un anno dalla data di laurea OFFERTA EARLY BIRD SPECIAL: le prime 5 domande di iscrizione pervenute entro il 31 Dicembre 2011 avranno diritto ad una quota di iscrizione scontata del 20% Quote d'iscrizione E.B. SPECIAL: E.B. SPECIAL educational* : € 224.00+ iva E.B. SPECIAL professional: € 360.00+ iva. ulteriori info, dettagli e iscrizioni: http://www.co-de-it.com/wordpress/nexus-advanced-grasshopper-workshop-with-uto.html…
(18, 11, 0, 17), also put in the assembly component.
How can I know which value of the reaction forces correspond to which support?
In the manual is stated that when the reaction force component is used, than the values are displayed in ascending sequence of the corresponding nodes.So if I input the support nodes like thispoint with index 18point with index 11point with index 0point with index 17are the reaction forces displayed like this (per loadcase)?0 - reaction forces in point with index 01 - reaction forces in point with index 112 - reaction forces in point with index 183 - reaction forces in point with index 17
Thanks!
BestLara…
into new tree, so that branch {0} has points from branch {0} {1} {2} combined, branch {1} has points from {2} {3} {4}... as it shows in the atached image.
The main problem is that points need to overlap in the new tree.
Any suggestions?…
para poder parametrizarla - Entender cómo se gestionan los datos con Grasshopper - Asociar formulaciones matemáticas a modelos paramétricos - Panelizar y triangular superficies - Parametrizar estructuras sencillas - Saber deformar modelos tridimensionales paramétricamente - Elaboración de algoritmos simples y aplicarlos a modelos tridimensionales - Exportar e importar tablas de datos
El curso será impartido por dos Authorized Rhino Trainers.
También te informamos de que hemos renovado el temario del curso, preparado específica y exclusivamente por nosotros, y que es revisado y ampliado continuamente, gracias a la experiencia de cursos anteriores. El curso tiene un formato intensivo de 18 horas, cuyo horario es: - viernes, de 16 a 20; - sábado, de 10 a 14 y de 16 a 20; - domingo, de 11 a 14 y de 16 a 19.
Si estás interesado en apuntarte, contáctanos en: cursos@frikearq.com…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
ización de estructuras, panelización de superficies, gestión y conexión con tablas de datos, automatización de dibujo, programación visual … Adjuntamos el temario del cuso. El contenido del curso ha sido revisado y ampliado, gracias a la experiencia de nuestros anteriores. Está orientado a profesionales y estudiantes de arquitectura y diseño en general.
Será impartido por dos Authorized Rhino Trainers en Madrid, en la calle Bailén. Tiene un formato intensivo de 18 horas; el horario es: viernes, de 17 a 21; sábado, de 10 a 14 y de 16 a 20; y domingo, de 11 a 14 y de 16 a 19. El número de asistentes está limitado a un máximo de 8 personas.…
Added by Miguel Vidal at 11:11am on December 17, 2009
}
0,3
{7}
1,2
{8}
1,3
{9}
2,3
{10}
0,1,2
{11}
0,1,3
{12}
0,2,3
{13}
1,2,3
{14}
0,1,2,3
I want it to be parametric so I can have it for any set of indexes
I have tried to solve it with points and then removing duplicate points but it's not helping much
any help is truly appreciated
…
7 -18.2
8 5.02
9 12.4
10 18.1
11 7.01
12 5.11
13 2.35
this data is waveform data.
i want to pick out only climax(for example in upper data, number 1 and 10) from this data.
i have this problem...that is, i do not know to do what.
i think my English is strange...so you are difficult to understanding my question.…