I am recently involved a LEED V4 NC project. During the process, I found LEED V4's daylighting simulation has been changed. According to my knowledge ,I knew that Honeybee for Grasshooper can calculate the Useful Daylighting illuminance.
After studied the Honeybee_Annual_Daylight_Simulation_Example form (http://hydrashare.github.io), I got the UDLI <100,100< UDLI <2000 and UDLI >2000 .This example is performed very nice.
But the requirement of LEED V4 EQ CREDIT: DAYLIGHT Option 2 need illuminance levels will be between 300 lux and 3,000 lux for 9 a.m. and 3 p.m.
So I am confused. Is the any method for Honeybee to do this level of illuminance calculations?
Tags:
Replies are closed for this discussion.
Hi,
Grid based simulation shall be used for such point in time analysis.