Grasshopper

algorithmic modeling for Rhino

Tosional sensitivity analysis of a structure to EN1998

Parametric analysis of the torsional sensitivity of a floor according to Eurocode 8. Checks whether the radius of gyration of a floor structure lies inside the ellipse of torsion.

Views: 220

Comment

You need to be a member of Grasshopper to add comments!

Comment by djordje on December 2, 2012 at 3:14pm

Thank you for the reply Odysseas.
One more epic Grasshopper project of yours.
You truly justify your name!

Comment by Odysseas Georgiou on December 2, 2012 at 12:19pm

Thanks.

Yes, you just reference all the curves which correspond to the vertical elements and the floor envelope and it calculates the rest. I guess you can set up some rules for optimisation in grasshopper but you'll first have to define your lateral stiffness limits for the size of the columns/walls as well as the vertical load resistance demands. This example is based in tweaking the pre-sized columns in order to satisfy the torsional sensitivity demand of EN1998. 

Comment by djordje on December 2, 2012 at 4:37am

Very nice!
Do you manually need to assign the load bearing walls/columns?