d changing it to 0.01 doesn't change the number of errors, after re-plugging the wires.... I guess the issue was not containment but the intersection component.... that explains the change in values when Ching changed the absolute tolerance values... …
u; IL 24, Lightweight Principle
Dtsch.-Engl.. (Form, Kraft, Masse 4; Mitteilungen des Instituts für leichte Flächentragwerke der Universität Stuttgart)
Frieder Klenk
Hrsg.: Univ. Stuttgart, Institut für Leichte Flächentragwerke -IL-;
1998, 288 S. m. zahlr. Abb., 2 Beil. 21 x 27 cm, Kartoniert/Broschiert
Sprache: Englisch
ISBN 978-3-7828-2024-0 | Krämer, Stuttgart…
the polyline . Although I'm able to create an Arc with the CCX Pt 2 .
Please help as I'm constantly running into this problem
THANKS
I uploaded the .gh file…
Added by Yves Allemann at 12:34pm on January 2, 2017
Here it the RhinoScript that I am using:
'Option Explicit
'Rem Script written by Giulio
'Rem Script version lunes, 10 de noviembre de 2008 21:00:00
'Rem This script is licenced to you under the conditions shown at
'Rem http://www.giuliopiacentino.com/this/
Call Main()
Sub Main()'starts command
Dim arrLfStart(),arrRxStart(), arrLfEnd(), arrRxEnd(), arrLinks(), i 'sets intergers
Dim links: links = 36 'number of cylinders (links)
ReDim arrLfStart(links), arrRxStart(links), arrLfEnd(links), arrRxEnd(links), arrLinks(links) 'combines integer with number
Dim angleDist:angleDist = Rhino.PI / 10
For i=0 To links 'sets integer
'The following sets the path
arrLfStart(i) = Array(Cos(i-angleDist)*3 + Cos(i*12)*12, Sin(i-angleDist)*3 + Sin(i*12)*12, i*5)
arrRxStart(i) = Array(Cos(i+angleDist)*3 + Cos(i*12)*12, Sin(i+angleDist)*3 + Sin(i*12)*12, i*5)
arrLfEnd(i) = Array(-Cos(i-angleDist)*3 + Cos(i*12)*12, -Sin(i-angleDist)*3 + Sin(i*12)*12, i*5)
arrRxEnd(i) = Array(-Cos(i+angleDist)*3 + Cos(i*12)*12, -Sin(i+angleDist)*3 + Sin(i*12)*12, i*5)
'The following adds cylindars according to specified points
Call Rhino.AddCylinder(IntraPts(arrLfStart(i), arrRxStart(i), 0.5), IntraPts(arrLfEnd(i), arrRxEnd(i), 0.5), 0.5)
Next
'The following adds surfaces to the path
Call Rhino.AddLoftSrf(Array(Rhino.AddInterpCurve(arrLfStart), Rhino.AddInterpCurve(arrRxStart)))
Call Rhino.AddLoftSrf(Array(Rhino.AddInterpCurve(arrLfEnd), Rhino.AddInterpCurve(arrRxEnd)))
End Sub
Function IntraPts(byRef p1, byRef p2,byRef n)
'Rem This function gives the first point out if you use n=0,
'Rem with n=1 it gives the second point.
IntraPts = Array( p1(0)*(1.0-n)+p2(0)*n, p1(1)*(1.0-n)+p2(1)*n, p1(2)*(1.0-n)+p2(2)*n )
End Function
I know that the script works in RhinoScript. If anyone could help me out I would appreciate it.…
Added by Adam Smith at 1:57pm on September 9, 2010
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…