be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
een shot and there are two pull down menus of PT. The left if clicked shows the older version and works fine, but when the right menu is clicked the software freezes and crashes.
In my PC, Rhino 5 32 bit and 64 bit are installed and Rhino 4 as well. Just for your info.
Thanks.
…
n for me to add it in. If you find a useful plugin missing, just write a note and I will add it in.
However, I'm working on a message board feature. You will be able to add notes into any component to help others.
Updates are a subjective thing; components that are newly added that someone else is aware of, but you are not aware of. Perhaps an RSS feed of plugin updates would suit you better.…
IP format and include all the files material
is there something similar in RHINO 5 ? tried copying a file but material was lost
thanks a lot
Cheers,
H…
Added by Hakam husam at 2:18pm on October 11, 2015
e math to get the surface accuracy I'm looking for).
I'm dividing a circle, which represents the bottom of the endmill, then finding the intersection of SDL lines based on those points (just in the z direction for now as I own a 3 axis machine) and the surface. I then find the highest z point, and interpolate a curve with points using the original xy and the new z values.
I was planning on dividing both the curve and the circles by a length of .001, but this seems to be way too much. I was planning on using a similar strategy for a ballmill, populating the surface of half a sphere with points and finding the difference in length between those and those on the target surface, but that would be a significantly higher number of points.
Do I need a better strategy, a better pc, or am I asking for too much in terms of accuracy?
Thanks for the help,
Justin
…
are not copy with the number that belong to each other, like:
untrimmed surface0 should be 41 pieces
untrimmed surface1 should be 28 pieces
untrimmed surface1 should be 21 pieces
it result like this
exclude the 1st and 2nd pieces,the others all is untrimmed surface 1
and the attachments is the result that i want, I done it one by one.…
at your original list of numbers, if I am to go through and check manually to see what I should be getting out, I think you should only get a few outputs (which is why I was confused by all the outputs at the end of the definition.
For example, just as an example I started with X1 as 279 (item index 11). When I did the math, the only indexes that I got were 15,28, and 33.
This is because:
since 279 is positive, look for next number that is at least 180 less or 360 more than X1.
the value of 78 (item index 15) is the first value to satisfy this requirement.
Then, since 78 is smaller than 279, we are looking for the next value at least 180 more or 360 less than 78.
The value 272 (item index 28) is that next value.
Then since 272 is larger than 78, we are looking for the next value at least 180 less or 360 more than 272.
The value 52 (item index 33) is the next value.
So the definition should output the following:
indexes 15, 28, 33.
Does that make sense?…
Added by Brian Harms at 4:20pm on December 10, 2011
requiredKeys_ input of the "OSM Shapes" component. This is not the source of your problem though, but still I mentioned it in case you solve your issue, and afterwards want to use the "OSM Shapes" component.
The current (Win32Exception): WindowsError is the very same error message that you reported back in February.For some reason, your Windows is not allowing the Gismo "OSM Shapes" component to delete C:\MapWinGIS_installation_folder\gdal-data\osmconf.ini file.
You previously solved it by allowing the full access control to it, so I am not sure why it is not working now.Windows 10 seems to be the most overprotected operating system among other Windows versions, at least judging by the questions people asked so far.
Maybe you can try to turn off all the services which prevent users from changing certain files, like UAC or maybe even your antivirus?
Try this:
1) Close your Grasshopper and Rhino.2) Restart your PC3) When it boots up again, in your Start menu's search box type: "UAC". Click on it, and a new User Account Control Settings window will open. Set the bar on the left to "Never notify".4) Completely turn off your Antivirus.5) Check once again if your access control to the C:\MapWinGIS_installation_folder\gdal-data\osmconf.ini file is still set to the values you previously reported in this post.6) Right-click on "Rhino 5" icon and then choose: "Run as administrator".7) When Rhino boots up, run Grasshopper, and open the newest create_3dbuildings_trees_streets.gh file from here.If none of this helps, maybe you have some other application which deals with access to files on your system? Malware removal application or similar? Try turning it off too.…
Added by djordje to Gismo at 9:10am on April 3, 2017
bug. Have I missed the solution or is it something that you haven't been able to replicate?
I have been using Rhino 4 ever since at work but am able to use Rhino 5 at home with the same operating system (nearly Pro vs. Home Vista)
Any insight would be appreciated.
thanks
Danny
…
Added by Danny Boyes at 9:18am on September 24, 2012