which doesn't exist in the actual problem spec. If galapagos is allowed to change the column position in all possible directions, it is less likely to get stuck in some local optimum.
Let's assume that (all other things being equal) column 20 would yield the best possible answer. The current state of the system though is at column 26, which is pretty good too, just not as good. Galapagos is more likely to 'mutate' the state a little bit instead of a lot, so it'll explore the columns near 26. However 20 isn't near 26 at all, only 25 and 27 are nearby, and maybe 24 and 28. But they'll all worse answers, so after sampling in those directions GP will abandon that as fruitless.
If however you specify the columns using two variables, then the columns near 26 are 20, 25, 27 and 32. That's a far richer space to explore which much better approximates the real problem.…
ectural project, the efficiency of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
ay be loading it from Rhino 4, but even when I un-installed GH for Rhino 4, GH rhino 5 still loading that version. The strange thing is that when I check Tools-options-plug ins, GH -properties it shows the right file name and path of GrasshopperPlugIn.rhp, and the right registry path too that is in Rhino 5 Plug ins. So why on earth it is loading that previous mysterious copy?, and where it can be located?
Any steps I need to follow that may solve the problem?…
Added by Zayad Motlib at 12:02am on March 11, 2013
ms auctioned off at Christies any time soon. There are a few people making jewelry with concrete, juxtaposed with precious metals and stones; in some cases they are making an ironic statement, in others, it's purely an aesthetic choice. Still, I imagine there's some hesitation on the part of the buyer afraid of flirting with unorthodoxy.
http://www.jcottergallery.com/alternative-materials.html
And worst of all is that volume scales as length^3 so unless you are a balloon artist, everything gets more expensive and unwieldy, be it of glass, gold or PVC pipe.…
tion...there are 90 different groups of breps, so i need them to be re-oriented to their original position and with the new bounding box "attached".
see the image below for clarification.
I know there must be an easier way....but my brain its about to pop from the 3 previous gigantic definitions to get this panels modeled >_>
thx a lot in advance
…
Added by Yerko Lucic at 3:37pm on February 14, 2012
ese are some examples.
https://n-e-r-v-o-u-s.com/blog/?p=3983
https://mathematics.culturalspot.org/asset-viewer/10-000-circles-1/YgHExQHhZyL5_Q?exhibitId=QAJCFieRlsF8Lw
Thanks for the insight.
Shynn…
ions! == fantastic.
1. When at begin = false mode > (a) you can now see things and (b) you can reduce your panels (prior the interactive massacre,i.e. begin = true) based on the famous algo of mine as written in this top secret (C)(tm) function:
MassacreOnList(sListSorted, pC, CofCPanelDist) : in Plain English:: take no prisoners.
2. make a break > buy a book (you know what kind) > learn things > sky is the limit (in fact events/delegates is the limit - nasty stuff).
3. in order to get your def (the complete thing) YOU MUST post here a hymn (original, lyrical and passionate) related with the ultimate thing: my Panigale 1199.
best, Lord Of Darkness
…
picture:
... and on a PC without anything attached to the serial port. When you open the port, start the read component and its timer, do you then get a stream of <empty> values in the log output? (hmmm... I suppose that's only reasonable - but still, you are also seeing this?)
I suppose that, because of the mutually exclusive behavior of both the spider and grasshopper (i.e. only one at a time can access the COM port), we can deduce that we are listening on the correct port.
Am I listening on the correct pin (if such a notion makes sense at all)? If I look back to the spider software, I see that 9 channels are listed and that it's only the measured value on channel 0 that changes when I press the load cell. Channels 1, 2, and 3 report OVERFLOW; 4, 5, 6, and 7 are pretty much constant at 0.000 to 0.005 V; and channel 8 says FFFF. I do not know how things like that work so I do not know if they reflect reading from the 9 pins on the D-sub 9 connector.
As for your BTW question: no, I don't need to record all of the sensor values. I suppose that the Out value on the Read component will always reflect the most current value and that's all that I need to get on with life. In the end, the idea is that we have 4 load cells in the 4 corners of a plate onto which a vertical pipe is fixed. Loads are then put on the top end of the pipe and we'll have to visualize both direction and magnitude of the bending moment that is calculated from the compression - tension readings from the load cells... We've done this on a scaled model and streamed load cell information into MatLab. Now we'll have to use a different datalogger and I was hoping to be able to do the post processing in Rhino.
wim…
rights to register the "mapwingis.ocx" file.Francesco, would you be patient just a tiny little bit, so that we could try something else? I would be grateful if you could.
1) Close Grasshopper and Rhino2) Run the Revo Uninstaller Pro and uninstall your MapWinGIS application along with removing all the leftovers from the registry.3) Restart your PC, and once it boots again, make sure that you are logged in as an Adminstrator.4) In your Start menu's search box type: "UAC", which will find your User Account Control Settings. Click on it, and a new window will open. Set the bar on the left to "Never notify".5) Turn off your Antivirus, which ever it is.6) Download the 64 bit version of v4.9.4.2 MapWinGIS.7) Right click on downloaded MapWinGIS-only-v4.9.4.2-x64.exe file, and choose "Properties". If there is "Unblock" button click on it, and then click on "OK". If there is no "Unblock" button, just click on "OK".8) Left double click on MapWinGIS-only-v4.9.4.2-x64.exe file and install it to "C:\dev\MapWinGIS" folder. Choose "Full installation" during installation process!9) In your Start menu's search box type: "CMD". Once the "Command prompt" appears do not left click on it! Instead right click on it, and choose "Run as Administrator".10) A command prompt window will open. Type the following command:
"your_regsvr32_folder_path\regsvr32.exe" /u /s c:\dev\mapwingis\mapwingis.ocx
If command does not result in an error message, then type this one afterwards:
"your_regsvr32_folder_path\regsvr32.exe" /s c:\dev\mapwingis\mapwingis.ocx
11) If no error appeared again, then open your Rhino and Grasshopper and check what Gismo_Gismo component prints from its "readMe!" output.If errors appeared, it would be nice if you could post their screenshots.…
Added by djordje to Gismo at 5:46am on March 27, 2017