ll these 12500 points.
Group 1 would represent the point located at 0, 5, 10, 15, 20 etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc.
I can create the pattern but the selection of points are all the points in row 0 and then all the points in row 5 and so on.
I would like the selection of points to start at the bottom left, and sequentially continue to the right and then continue on the 2nd row (left to right & bottom to top). i am hoping the pattern i am trying to achieve is more understood with the quick screen capture I uploaded.
the end goal is to be able to select all the points in the grid that are in each pattern.
Thanks in advance for any guidance with this. …
Added by Alyne Rankin at 6:53am on October 11, 2017
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
53 → 53 → 63 → 74 → 74 → 84 → 9
As you can see from the above list the connection sequence comes in waves of three, where each group of similar indices on the left is associated with a group of three incrementing indices on the right.
Some combination of Series components will probably generate this list, but it'll only work for the first ring, the second one will need a different connection pattern. It is perhaps better to just encode the integer pairs by hand. But then you cannot change your mind about the number of sides later.…
Added by David Rutten at 10:39am on October 21, 2015