EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…
e aquí!
Course Description:This course is for design professionals who are looking to efficiently learn concepts and features of Grasshopper at an accelerated pace in an instructor-led online environment. The online course will meet for a total of four sessions. We will have a short orientation to cover the GoToTraining module. The Grasshopper training sessions will be split into three half-day sessions. Details...
Horario:Introducción – Febrero 22, 2016De: 9:00 a.m. – 10:30 a.m. (EST) Clases – Febrero 23 al 25, 2016Curso: 9:00 a.m. – 10:30 a.m. (EST)Break: 10:30 a.m. – 10:45 am (EST)Curso: 10:45 a.m. – 1:00 p.m. (EST)Q&A (Preguntas y tarea) de 1:00 p.m. – 1:35 pm (EST)Para Registrarse:correo electrónico: Jackie Nasserteléfono: 305 513 4445http://mcneelmiami.com/online___espanol/m/1/15/2016…
run the simulation I get this in the command line:
An error occured in the display pipeline @ 10:35:29(856ms)An error occured in the display pipeline @ 10:35:29(856ms)An error occured in the display pipeline @ 10:35:30(387ms)An error occured in the display pipeline @ 10:35:30(387ms)
etc
etc
I have tried changing between Windows and Open GL in 'Pipeline and Conduits' settings in Options> Appearance> Advanced Settings> Other Settings - doesn't solve the problem.
I am running:
- Rhino 4 SR 8
- Grasshopper 0.80004
- Kangaroo 0.044
rhino model and grasshopper definition attached....
any help would be really appreciated!!
thanks,
Jeg…
ample, the columns are a 40 cm x 40 cm square for the first two floors and then a 35 cm x 35 cm square for the third and fourth floors, etc. I have been able to figure this out for 2, 4, and 6 floors but not beyond, due to the following error when I tried to make an 8 floor model: Singular Stiffness-matrix: Can not solve static system.
It's also "hard coded" so floor number no longer works as a parameter (I have to make a new file for each number of floors, which is not ideal). I'm wondering if there is an easier/better way to achieve this goal?
My .gh files for the 6 floor building and 8 floor building (which produces the error) are attached. Any suggestions or ideas? Thanks in advance!
Best, Tess…
X[]={ 0, 100, 35, 0, 200, 35, 350, 289, 304, 523, 234, 123};
With much more number, but the concept is it.
I have two problem:
1 - I can't insert it "{" in the format text because he think is a variable declaration.
I think i could solve this
2 - I',m not able to insert the numbers all together, it create a concluse line for every number, like this...
int pointX[]={ 0,};
int pointX[]={ 100,};
int pointX[]={ 35,};
...
…