choose the smaller as it.
(2)The board perforated in precise percentage,like 31%.
(3)Holes around edges should be handle carefully like no too approach to edges, using radius of them as well.
I has been try on galapagos, hoopsnake. Different methods are welcome, it`s just need to hit the goal. What i do really care is the thinking process, and i can`t figure out a good way to solve this problem. If you have an idea please tell me and i will try to work out on it. …
hopper) and High Definition visualizations (V-Ray) and exploring its scientific innovations supporting the users' platform philosophical ideas.
SESSIONS: 5 sessions of 8 hours (40 hours total)
E-MAIL: educacion@chconsultores.net
REGISTRATION: (55) 56 62 57 93
TECHNICAL INFO: 044 (55) 31 22 71 83
INSTRUCTORS: Have past experience working at Gehry Technologies, and participated at studios with Eric Owen Moss and Tom Wiscombe at SCI-Arc (Southern California Institute of Architecture).
Day 1: Introduction to MAYA tools, 3D exercise start.
Day 2: Continue 3D exercise.
Day 3: Original 3D architecture design.
Day 4: Grasshopper optional application on 3D architecture design.
Day 5: V-Ray Application on 3D architecture design.
30 DAY TRIAL SOFTWARE DOWNLOAD:MAYA 2012: http://www.autodesk.com/products/autodesk-maya/free-triaRHINO 4: http://s3.amazonaws.com/files.na.mcneel.com/rhino/4.0/2011-02-11/eval/rh40eval_en_20110211.exe3DS MAX 2010: http://www.autodesk.com/products/autodesk-3ds-max/free-trialVRAY FOR 3DS MAX: http://www.vray.com/vray_for_3ds_max/demo/thankyou.shtml#thankyouPHOTOSHOP e ILLUSTRATOR: https://creative.adobe.com/apps?trial=PHSP&promoid=JZXPS
www.helenico.edu.mx
www.scifi-architecture.com/#!workshops/c1wua
LIKE US ON: www.facebook.com/scifiarchitecture
…
e perimeter of each floor into 32 points (as you can see in the draws). I want to connect each point like a dual direction net. I think that i have to use some math parameter to filter the points of the list that i want to join, but i just can't find the way. In theory i know that i have to join the 0 point of the first curve to the 1 of the second, and then to the 3, and son on ... and after this the opposite (the 0 to the 32, to the 31). Anyone has an idea? …
bro su Grasshopper "Architettura Parametrica", co-director della AA Rome Visiting School per la Architectural Association di Londra (http://www.arturotedeschi.com/).
Il corso introdurrà il software Grasshopper, plug-in per la modellazione parametrica in Rhino. I partecipanti saranno guidati attraverso gli aspetti più importanti del programma e le principali tecniche per la programmazione visuale all’interno di Rhinoceros. Il corso è rivolto a studenti con esperienza minima nella modellazione 3D e si articolerà in lezioni teoriche ed esercitazioni. Sarà rilasciato un attestato di partecipazione.
principali argomenti: - Introduzione alla progettazione parametrica: teoria, esempi, casi studio - Grasshopper: concetti base, logica algoritmica, interfaccia grafica - Nozioni fondamentali: componenti, connessioni, data flow - Funzioni matematiche e logiche, serie, gestione dei dati - Analisi e definizione di curve e superfici - Definizione di griglie e pattern complessi - Trasformazioni geometriche - Data tree: gestione di dati complessi - Meshes e Subdivision Surfaces (Weaverbird)
GENOVA 11 > 14 APRILE 2013 programma completo ed iscrizioni…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
rce',)Failed to copy the object. Returning the original objects...This can cause strange behaviour!Duplicate surface name! Name is changed to: Overhang (roof)_DupDuplicate surface name! Name is changed to: Adiabatic walls_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_Dup_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_Dup_Dup_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_Dup_Dup_Dup_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_Dup_Dup_Dup_Dup_DupDuplicate surface name! Name is changed to: Adiabatic walls_Dup_Dup_Dup_Dup_Dup_Dup_Dup[1 of 7] Writing simulation parameters...Ground temperature data contains monthly average temperatures at 3 different depths .5 meters (1st)2 meters (2nd)4meters (3rd)respectively[2 of 6] No context surfaces...[3 of 6] Writing geometry...[4 of 6] Writing materials and constructions...[5 of 7] Writing schedules...[6 of 7] Writing loads and ideal air system...[7 of 7] Writing outputs......... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf
Analysis is running!...c:\ladybug\unnamed\EnergyPlus\eplusout.csv......
Done! Read below for errors and warnings:…
helped me solve some geometry problems).
I uninstalled energyPlus and installed again, updated the components, and hanges replaced the once that were not automatically replaced.And I have a deadline :(
Could it be because there are no materials assigned?
Thanks a lot.
Nita
p.s.
Analysis period is from 1 JUN to 31 DEC Between hours 1:00 to 24:00 Current document units is in Meters Conversion to Meters will be applied = 1.000 [1 of 7] Writing simulation parameters... Ground temperature data contains monthly average temperatures at 3 different depths .5 meters (1st)2 meters (2nd)4meters (3rd)respectively [2 of 6] No context surfaces... [3 of 6] Writing geometry... [4 of 6] Writing materials and constructions... [5 of 7] Writing schedules... [6 of 7] Writing loads and ideal air system... [7 of 7] Writing outputs... ... ... idf file is successfully written to : E:\Skins\PArametric_study\basecase\basecase\EnergyPlus\basecase.idf
Analysis is running!... E:\Skins\PArametric_study\basecase\basecase\EnergyPlus\eplusout.csv ... ...
Done! Read below for errors and warnings:
Empty…