ASS 2017 Conference in Hamburg, Germany. Join them to:
Learn how to use simulation-based optimization in Grasshopper
Learn about the differences between optimization algorithms in Grasshopper and when to use them
Learn how to assess the performance of optimization algorithms
Learn about differences between single and multi-objective optimization algorithms
Experiment with benchmark problems
Experiment with optimization problems from your own practice and research (bring your own optimization problems)
Experiment with optimization and visualization tools not yet released publicly
Thomas and Judyta are researchers in architectural design optimization. Thomas is the lead developer of the machine learning related optimization tool Opossum and Judyta a co-developer of the particle swarm optimization tool Silverye. Adrian is the founder and the owner of Architektura Parametryczna – the biggest Polish consultancy company in parametric design. (Find Thomas’ and Judyta’s work on ResearchGate here and here.) Registration closes on Tuesday, July 25, 2017.
Registration through the IASS website:
https://express2.converia.de/frontend/index.php?folder_id=943
Facebook event page:
https://tinyurl.com/ycv24m8g
…
metric/parəˈmɛtrɪk/adjectiverelating to or expressed in terms of a parameter or parameters.art/ɑːt/nounthe expression or application of human creative skill and imagination, typically in a visual form such as painting or sculpture, producing works to be appreciated primarily for their beauty or emotional power.// Summer School 2017 3 day intensive workshop for design students & professionals will delve into computational & parametric methods (using Rhino3D & Grasshopper3D) to create data-driven art installations, physically manifested into a space through hands-on fabrication & assembly.The experimental studio will run across 2 cities in India (New Delhi & Mumbai) and investigate the agenda of ‘filling the void’ at art installation scale, through the use of computation and parametric methods. Studio is designed as a 3-day event in both cities comprising of technical tutorials, teaching sessions, prototyping & presentations culminating in a symposium / round-table conference / open discussion with leading / emerging professionals that demonstrate computation, parametric design or alternative techniques in their work / practice / academia. // Cities & Dates*New Delhi – 30th June to 2nd July 2017 (Friday to Sunday)Mumbai – 7th July to 9th July 2017 (Friday to Sunday)//VENUE: DELHI: Startup Tunnel, Vihara Innovation CampusD-57, 100 Feet Rd, Pocket D, Dr Ambedkar Colony, Chhattarpur, New Delhi - 110074MUMBAI: Raffles Design International, MumbaiHi Life, 2nd Floor, Phirozshah Mehta Road,Santacruz (W). Mumbai – 400054// Registration DatesAll Registrations End 4 days prior to workshop start date (Or till seats last)// About rat[LAB] EDUCATIONrat[LAB] EDUCATION is an initiative by rat[LAB]-Research in Architecture & Technology (www.rat-lab.org) to start a new discourse in architecture & parallel design disciplines with the use of ‘computational design’ & it’s various subsets. Spread across various cities / countries, we are establishing a global dialogue in the domain of computational design by actively organizing and participating in workshops, lectures, presentations & symposia. While rat[LAB] has taken a top-down approach of exploring computational design through industry, a parallel, bottom-up approach is also in-line to involve students of all levels, from design & related backgrounds.…
le discontinuous list of index numbers and I'd like to be able to generate a set of domains where each span of numbers would have its own domain. For example:
This list: 5,6,7,8,9,22,23,24,25,26,77,78,79,80,81...
Would give these domains: 5 to 9, 22 to 26, 77 to 81...
I'm at a loss as to how I can achieve this though. I know I can use the bounds function on the list but that would give a single domain, not several. In case it helps the list in question was generated by a true/false cull pattern from the complete list of indices so simply determining the indices of the beginning and end of each chunk of 'trues' in the cull pattern would work as well as it would give the same domains. I can post an example file if anyone would like but I figure this is a pretty general issue.
So anybody have any ideas on how to solve this multiple domains from a single list problem? Thanks in advance for any help at all, I'd really appreciate it!
James…
ing the clipper code directly to GH2 so it is accessible natively.
Much better offset/inset curves! Added a 'Tolerance' slider... Fast! ~15+ seconds to open:
With '%Tool Diameter' set to 0.5 (50%) and 'Count' set to 100, time is ~1.5+ mins, though there are three distinct spot anomalies that need further examination...
…
box) generating so many edges?
You can see that I want to check the volume of the "pipes" , but there are so many duplicates (or at least very close values) that it gives wrong results. How can I remove duplicates here? Vertices also have many duplicates, face might have too.
Second - how can I extrude the different panels (the ones in the end geometry, that are already rotated) such, so the extrusion happens perpendicular the each of them. I will cut them out of 3 mm Plexiglas, but I can cut it only in 90°.
Thanks to anyone that is willing to help, I already tried so many options and nothing worked...…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
rld of Parametric Design by learning Parametric Design Techniques with Grasshopper.
For details and registration check out: http://www.d-nat.net/topologies-entry or email: contact@d-nat.net
The workshop will also prepare you for the entry level of the intermediate / advanced workshop Fabricated Topologies, which is taking place on Jan 17-21, 2017. Check out http://www.d-nat.net/fabricated-topologies for details.
…
Added by Zayad Motlib at 12:03am on December 15, 2016
e a "game changer" regarding lighting simulations and analysis. To harness the power of Grasshopper, the flexibility of Rhino in a lighting specific application is, I believe, already the future.
Because of the above I am a big proponent of Honeybee for the professional environment, but I feel that there are still a few shortcomings... from what I have tried.
1. It should be "photometrically" more comprehensive, not just for illuminance, luminance and energy (W.h). Other quantities are of great importance, namely intensity and flux.
2. Producing documentation is a big advantage (if not the main advantage) of dedicated packages such as Dialux or AGI32, it would be nice to see it as a strong feature in Honeybee as well.
3. Support for Eulumdat would be a nice feature.
4. There is a performance issue with multiple sources as you mentioned. I have tried a "simple" analysis with 120 sources and it takes, indeed, a substantial amount of time to produce the result. Don't know where the bottleneck is, perhaps not Honeybee's to blame, but it is a hindrance in using the software for complex simulations.
5. Material/surface design would benefit from more options.
Finally, do you have a roadmap of sorts and what can the users expect from Honeybee electic lighting in 2017?
Have a great year!! All the best.
…