f my list.I don't understand why, but I guess I must be too young user ^^In the original list, i have a path {0;0;0;4} with two index and after the random node, {0;0;0;4} has 88 index.Items are not correct?I would have a comparable structure has the right list on my jpg (photomontage...)How I can do that?Thank you in advance
…
): 'Rhino.Geometry.TextEntity' does not contain a definition for 'FontIndex' and no extension method 'FontIndex' accepting a first argument of type 'Rhino.Geometry.TextEntity' could be found (are you missing a using directive or an assembly reference?) (line 92) 2. Error (CS1061): 'Rhino.Geometry.TextEntity' does not contain a definition for 'AnnotativeScalingEnabled' and no extension method 'AnnotativeScalingEnabled' accepting a first argument of type 'Rhino.Geometry.TextEntity' could be found (are you missing a using directive or an assembly reference?) (line 94)…
i to usb cable and was able to connect Grasshopper with my digital piano realtime through a simple VB.NET component, no need for any other intermediate software. I used this library http://midiservices.codeplex.com/ (but there are several others).
The VB component outputs a list of 88 values that correspond to the intensity of each piano key at the current time (if the pedal is on and a key is depressed the value is halved, if the pedal is off the value is 0).
The rest of the definition is just to do something with this data. It uses these values to display each note as different floating colors that move with the wind (using Kangaroo). The strength of the wind changes as the music dynamics change.
If there are several devices connected you might have to change the line device.Open(0) to another number.
Definition: piano_midi.gh
…
18): 'Rhino.Geometry.AnnotationBase.Text' is obsolete: 'Use RichText or PlainText' (line 88)
2. Warning (CS0618): 'Rhino.Geometry.AnnotationBase.FontIndex' is obsolete: 'Use Font property instead' (line 92)
3. Warning (CS0618): 'Rhino.RhinoDoc.Fonts' is obsolete: 'Use DimStyles table instead' (line 92)
1. Error (CS1061): 'Rhino.Geometry.TextEntity' does not contain a definition for 'AnnotativeScalingEnabled' and no extension method 'AnnotativeScalingEnabled' accepting a first argument of type 'Rhino.Geometry.TextEntity' could be found (are you missing a using directive or an assembly reference?) (line 94)
Wondering, if perhaps, you will be updating for Rhino 6 compatibility?
Cheers
Lyndon
…
make a new curve from points I attempt to do it by writing:
Curve cv = new Curve();
This gives me the error:Error: 'Rhino.Geometry.Curve.Curve()' is inaccessible due to its protection level (line 88)
I have also tried calling the CreateInterpolatedCurve() from the Curve class, but
Curve cv = null; cv = new Curve.CreateInterpolatedCurve(Mould.Branch(0), 3);
But from this i get:
Error: 'Rhino.Geometry.Curve.CreateInterpolatedCurve(System.Collections.Generic.IEnumerable<Rhino.Geometry.Point3d>, int)' is a 'method' but is used like a 'type' (line 89)I'm really quite lost about how I can this to work. Can anyone help me?…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
points within the bounds of the site boundary and use each location as an attractor point controlling a variable at each point in the grid (radius of a circle/height of a cube/colour based on a gradient etc.).This would be based on proximity to the attractor points with the effect of each attractor point essentially scaled by the percentage associated with it. For example a location with 88% visitor rates would have a more dramatic effect than a location with 26% visitor rates.
I've had a bit of a play around but can't seem to get beyond the point of what is shown in basic point attractor tutorials online. I'm definitely a novice.
Here's how I figured it would be done:
1) Create a grid of source points within a boundary curve.
2) Select 18 pre-defined attractor points.
2) Measure the distance between the source points and the attractor points.
3) Invert this data so that variables increase with proximity rather than decrease.
4) Give each of the attractor points a strength value from 1-100% based on the visitor rates.
5) Use the scaled data to control a variable at each of the source points.
6) Create some way to control the drop-off rate of the effect from each point.
It is at step 3 that I get completely lost.
I hope my description is clear. Any help would be greatly appreciated,
Adam
…
) function if you've already got a boolean value.
This expression:
x < 12
results in exactly the same things as this expression:
If( x < 12, True, False )
If() is only really useful when you want to return non-boolean data, like so:
If( x < 12, x, 100-x )
In this case, the expression will return either x, or 100-x if x is larger than or equal to 12:
x result
1 1
2 2
10 10
11 11
12 88
13 87
14 86
18 82
70 30
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
Added by David Rutten at 7:22am on August 10, 2011
d' and no extension method 'AnnotativeScalingEnabled' accepting a first argument of type 'Rhino.Geometry.TextEntity' could be found (are you missing a using directive or an assembly reference?) (line 94)
Along with some warnings:
1. Warning (CS0618): 'Rhino.Geometry.AnnotationBase.Text' is obsolete: 'Use RichText or PlainText' (line 88)2. Warning (CS0618): 'Rhino.Geometry.AnnotationBase.FontIndex' is obsolete: 'Use Font property instead' (line 92)
3. Warning (CS0618): 'Rhino.RhinoDoc.Fonts' is obsolete: 'Use DimStyles table instead' (line 92)
I've downloaded the latest version of FabTools.
I've completely un-installed and re-installed.
I've Googled everything I can think of to find a solution, but most references are circa 2013 which is probably under Rhino 5. Which works totally fine, BTW.
Does anybody know of a solution?
Thanks,
Michael
…
ts. Ideally, I'd like to set the exact number of points populating the region, ie 211 in GH = 211 visible in rhino.
(I was able to achieve the exact number of points using populate2d instead of sdivide, but could only get this to work with a simple rectangular region)
2) After I have exactly 211 points, I'd like to populate each of the points with a block made in rhino (for example: the stick figure man seen in the view)
(One idea is that I build a dummy geometry and replace later with my block in rhino. But how do I make this change universally over the 211 points?)
…