le data is not ( data is give on the hour: 7:00, 8:00, 9:00 ...) and DAYSIM seems that it dose not calculate external horizontal diffuse illuminance.
Thanks
…
etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc. "
except in data, the branches start at 0, so 'group 1' is branch 0
as for the order of your points, that depends on the input prior sorting...
yrs …
en 3 of them, and one poolyline between two of them.
It would also be very nice if i could control it so that only the successive ones can be connected
so if {0:0:0} has 8 points and {0:0:1} has 8, as do {0:0:5} and {0:0:6} i would like to have this as two polylines, not one continoous that would in this case jump three branches (or curves that are shorter).
Does this make any sense?…
Added by Dusan Bosnjak at 2:08pm on September 28, 2009
s 8, 4, 2, 10, 1, 3, 8, 4, 2, 0. But then for the end result to maintain all numbers above 5 but replace all numbers below with a defined number..Let's say zero. So then the list would read...8, 0, 0, 10, 0, 0, 8, 0, 0.…
dont get you, i am saying sleect numbers in range 1 to 10, starting from 1 with a step of 2.
1 to 10 by 3 = 1 4 7 10
1 to 10 by 5 = 1 6
1 to 10 by 1 = 1 to 10 = 1 2 3 4 5 6 7 8 9 10
Added by Steve Lewis at 3:15pm on November 11, 2013
i mean, i want a slider that can do 3 sides, 4 sides, 5, 6, 7, 8, 9 and 10. for the grids because I dont want to use a fixed grid shape such as square grid (4 sides only).
Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…