he same order of the list. for example i have a list with 4 different lenght of curve like this:
0= 10
1= 12
2= 8 (minimum)
3= 17 (maximum)
and wont to make a ranking that the longest curve gets the value 4 and the smallest the value 1, like this
0= 2
1= 3
2= 1
3= 4
i tried the sort list function, but it dosn`t work
can anybody help me!
thx a lot…
me. But if min = 5 and max = 12, then the range will be (12-5) = 7.
If you have only a fixed number of values, why not use a Value List to encode those?
You can still use a slider to select a value out of a list of presets, but the UI of the ValueList is more friendly, especially if the list of presets isn't particularly continuous. You can extend a single ValueList to have all 12 preset date+time combos as well.
Sliders values can be post-processed using an expression. For example you could add the 'x*3' expression to a slider, and then the value 0, 1, 2, 3, ... would be mapped to 0, 3, 6, 9, ...…
Added by David Rutten at 5:30am on January 21, 2016
output will show a tree with 3 branches of 4 integers each that I can pass on to other components. What is the best way to do it?
I have tried creating a tree and using a for loop to do so, but it didn't work.
Thank you for your help.
…
lue 12 on Value List and, automatically, obtain 17 in extrusion value, but these parameters should be send to relative controller (radius of circle, and amplitude of the vector for direction of extrusion). Thank you again.L…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…