NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
ider with a current value of 50 and an upper limit of 75.
Or:
25,50,75
Which would output slider with a lower limit of 25, a current value of 50 and an upper limit of 75.
Maybe spaces would be easier than commas.
Then maybe follows an optional letter for slider type:
0 5 10 f
Would be lower limit = 0, current value = 5, upper limit = 10, and it's a floating point slider.
It may sound like a lot of trouble but I hate editing sliders, lol.…
Added by Brian Harms at 2:28am on December 20, 2011
output: 0, 1, 3, 6, 10, 14, 17I have a basic understanding of programming and can understand vb.net better than I can write it. Any help would be greatly appreciated!ThanksJeff…
dont get you, i am saying sleect numbers in range 1 to 10, starting from 1 with a step of 2.
1 to 10 by 3 = 1 4 7 10
1 to 10 by 5 = 1 6
1 to 10 by 1 = 1 to 10 = 1 2 3 4 5 6 7 8 9 10
Added by Steve Lewis at 3:15pm on November 11, 2013
ric architecture (in my case, I chose the Frog Queen by Splitterwerk.
http://www.arcspace.com/architects/splitterwerk/frog_queen/frog_queen.html
I have a cubic building divide in 25 x 25 squares of 10 different shades of grey. Those shades are generated by a diversified ornementation. I am wondering if it is possible (and how) to set something that would say ''if a square is that tone of grey, change it in that type of ornementation''. I'm wondering if it is also possible that the shape was made with another set than pixellisation. If it is possible that they made 4 big X and that the pixellisation is set by their proximity to those X (closer it is to the X darker it is).
I'm really in trouble right now........ Help would be really appreciated.
Laurène Bachand…
created surface with sweep and rotate them with number of division. Section curves of 2Railsweep is defined with 3 Point arc and shape is also controlable.
You can change shape by sliding 16 paramteters.
The definition is rather long, hope somebody can modify with more sphiscated manner.
日本語
パラメトリックにボトルデザインをする.ghxファイルを作成しました。ボトルのプロファイルカーブを、参照となる円に対して、高さ、シフト、オフセットでコントロールポイントの位置情報を与えて定義。次にスイープで分割数だけ回転コピーして作成。
スイープの断面、3点円弧で作成し、形状コントロールするようにしています。
ボトル形状は、16のパラメーターをスライドすることで定義出来ます。
…