2;0
0
d
1
e
2
f
Path Mapper have a very interesting behavior, sometimes speed up things really easy.
(I've used the -1 to make paths start from 0 instead than from 1, with an input tree with 0 length branches or minimum branches length = 2 you will need to edit that)
:D
…
re say:
Error 54 El tipo 'GH_Component' is not defined. C:\Users\ususario\Documents\pruebaPlugin\prueba 10-9\Class1.vb
Error 55 property 'ComponentGuid' You can not declare 'Overrides' because not invalidate property at the base class. C:\Users\ususario\Documents\pruebaPlugin\prueba 10-9\Class1.vb
Error 56 The type 'Grasshopper.Kernel.GH_Component.GH_InputParamManager' is not defined. C:\Users\ususario\Documents\pruebaPlugin\prueba 10-9\Class1.vb
Error 57 The type 'Grasshopper.Kernel.GH_Component.GH_OutputParamManager' is not defined. C:\Users\ususario\Documents\pruebaPlugin\prueba 10-9\Class1.vb
Error 58 The type 'Grasshopper.Kernel.IGH_DataAccess' is not defined. C:\Users\ususario\Documents\pruebaPlugin\prueba 10-9\Class1.vb
…
思った感じになりません。
balls の代わりにplanarカーブを直接入れてみましたがエラーが出ます。
ファンクションにしてみたところ、forループので作った数値が反映されていません。
ファンクションのインスタンス?を出力していないと思い上記のようにしましたがエラーが出てしまいます。
以上の事から自分の認識が正しいのかよくわからなくなりました・・・
python自体の深いところをわかっているわけではないので余計こんがらがりました。
そこで、for b in ballsはどのような条件または使い方であれば使えるのでしょうか?
そして、上記のように別のオブジェクトに対しての使い方はどのようにすればできるのでしょうか?
2:同じファンクション内のdist = rs.Distance(self.pos,b.pos)についてですが
この文章も for b in balls によってbはBallのインスタンスであると定義?されたためb.posがbの位置であると分かるのでしょうか?
pythonは定義しなくても動いてしまうのでどのような時に使えるのか文章見ただけではよくわかりません・・・
大変細かいことかもしれませんが、よりpythonをしっかりと理解するためにも、どなたかわかる方ご教授いただけると幸いです。…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
RCH 01)
between 10 AM - 2 PM
Sun vectors where temperature is higher than 6 ° Ca>6 °C
4 hours od direct acces to sunshine in winter. It is a minimum useful for good passivesolar design. 57 Sun vectors
SUMMER ( jun 01 - sept 01)10 AM - 4 PM Sun vectors where temperature is higher than 19 ° Ca>19 °C
6 hours od direct acces to sunshine in summer.
447 Sun vectors
These vector are for gaining some energy trough PVs or something like that.
If you want to shade, ignore Summer!!!
…
hopper) and High Definition visualizations (V-Ray) and exploring its scientific innovations supporting the users' platform philosophical ideas.
SESSIONS: 5 sessions of 8 hours (40 hours total)
E-MAIL: educacion@chconsultores.net
REGISTRATION: (55) 56 62 57 93
TECHNICAL INFO: 044 (55) 31 22 71 83
INSTRUCTORS: Have past experience working at Gehry Technologies, and participated at studios with Eric Owen Moss and Tom Wiscombe at SCI-Arc (Southern California Institute of Architecture).
Day 1: Introduction to MAYA tools, 3D exercise start.
Day 2: Continue 3D exercise.
Day 3: Original 3D architecture design.
Day 4: Grasshopper optional application on 3D architecture design.
Day 5: V-Ray Application on 3D architecture design.
30 DAY TRIAL SOFTWARE DOWNLOAD:MAYA 2012: http://www.autodesk.com/products/autodesk-maya/free-triaRHINO 4: http://s3.amazonaws.com/files.na.mcneel.com/rhino/4.0/2011-02-11/eval/rh40eval_en_20110211.exe3DS MAX 2010: http://www.autodesk.com/products/autodesk-3ds-max/free-trialVRAY FOR 3DS MAX: http://www.vray.com/vray_for_3ds_max/demo/thankyou.shtml#thankyouPHOTOSHOP e ILLUSTRATOR: https://creative.adobe.com/apps?trial=PHSP&promoid=JZXPS
www.helenico.edu.mx
www.scifi-architecture.com/#!workshops/c1wua
LIKE US ON: www.facebook.com/scifiarchitecture
…
bit:
Unable to load grasshopper.dll plug-in: Rhino version not specified.
I've also tried the current WIP grasshopper (0.7 rev 57) and I receive a slightly different error message:
Unable to load grasshopper.rhp plug-in: Rhino version not specified.
A similar thread: http://www.grasshopper3d.com/forum/topics/plugin-eror
…
Added by Koabi Brooks at 1:30pm on October 2, 2010