which doesn't exist in the actual problem spec. If galapagos is allowed to change the column position in all possible directions, it is less likely to get stuck in some local optimum.
Let's assume that (all other things being equal) column 20 would yield the best possible answer. The current state of the system though is at column 26, which is pretty good too, just not as good. Galapagos is more likely to 'mutate' the state a little bit instead of a lot, so it'll explore the columns near 26. However 20 isn't near 26 at all, only 25 and 27 are nearby, and maybe 24 and 28. But they'll all worse answers, so after sampling in those directions GP will abandon that as fruitless.
If however you specify the columns using two variables, then the columns near 26 are 20, 25, 27 and 32. That's a far richer space to explore which much better approximates the real problem.…
Join Somewhere Something in Downtown Los Angeles for Summer 2016 workshop series.
Physical Computing with Firefly / August 27
GIS in Grasshopper / August 28
Grasshopper Plugins / September10+11
he installation folder, Drag & drop SYNTACTIC(green one) over your grasshopper canvas.3. Close your rhino and reopen it. 4. Type GrasshopperDeveloperSettings5. Tick the Memory load *.GHA assemblies using COFF byte arrays option6. Run grasshopper and enjoy plugin…
error message when GH starts loading (almost the last stage of loading).
I un-installed and re-installed it, but still the same error. When I checked the plug-ins in the options, it seems that it is loading the right one (from the file path), but I noticed when GH starts loading, it is loading GH version Sep 28, 2012.
Any idea how I can get around this problem?
thanks
…
ay be loading it from Rhino 4, but even when I un-installed GH for Rhino 4, GH rhino 5 still loading that version. The strange thing is that when I check Tools-options-plug ins, GH -properties it shows the right file name and path of GrasshopperPlugIn.rhp, and the right registry path too that is in Rhino 5 Plug ins. So why on earth it is loading that previous mysterious copy?, and where it can be located?
Any steps I need to follow that may solve the problem?…
Added by Zayad Motlib at 12:02am on March 11, 2013
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
(http://www.food4rhino.com/app/meshedit)
Weaverbird (http://www.giuliopiacentino.com/weaverbird/)
Make sure to install them before opening the example file.
For the Screenshot (27) error, make sure all of the *.dll files that came in the zip archive are unblocked and that you are using the Heron 0.2.0.0 GHA. You may have to replace the component with a new one from the Heron menu.…