output will show a tree with 3 branches of 4 integers each that I can pass on to other components. What is the best way to do it?
I have tried creating a tree and using a for loop to do so, but it didn't work.
Thank you for your help.
…
not sure about my method used to obtain the result.I think is really complex; do you know a smart method to simplify all my equation?
thanks guys!! :D…
Facades+ PERFORMANCE is two weeks away. Don't miss out on a great symposium and set of workshops April 11+12 in NYC. 8 Continuing Education Credits for each day.
http://facade.archpaper.com/ny2013/
9 8 7 6
5 4 3 2 1 0
I am triangulating this surface. I want to select just the red vertices. As you can note, I just need the inner vertices of this surface. I could do it mannually, but if I want to change the mesh density later, I will have to pick all of them manually again later.
Can someone help me?
Tks
…
yy.yyyy zzz.zzzzz
xxxxx.xxxxx yyy.yyyy zzz.zzzzz
xxxxx.xxxxx yyy.yyyy zzz.zzzzz
xxxxx.xxxxx yyy.yyyy zzz.zzzzz
...
So this is the problem: I have 44 file to process, and I wonder how (if it's possible) to "graft" the input so that I have 44 file in input + booleans and 44 panel in output...
In the "middle" of the cluster I have some flattern instruction so cannot directly add the whole input, I have to graft it from "outside" but I don't know how....
Any advice? Thank you!!
Umberto…
rve
10 curve
11 curve
12 curve
13 curve
...and I'd like to rearrange the order in which the curve are listed, to something like this:
{0,0,0}
0 curve
1 curve
8 curve
9 curve
10 curve
11 curve
2 curve
3 curve
4 curve
5 curve
12 curve
13 curve
6 curve
7 curve
I hope this makes sense.
Thank in advance for any advice,
John…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…
Thank you Marios,
but I want to put boxes on all the plane: if I divide U domain in 4 parts and V domain in 3 parts I'll have 12 boxes with 12 different heights in W
How can be done?
regards
Maurizio