r surfaces by EP results' components.
Having set a period from 9:00 to 19:00 for a single day (10th december), and using a slider from 0 to 10 (11 values, 0 is 9:00), the following mismatch occurs:
setting value 0 works for surface temperature but not for mean radiant temperature (warning says "stepofSimulation is outside the bounds of the comfResultMTX", but I do have 11 values from radiant temp matrix).
setting value 1 is rendered as "hour 2 of simulation" for surface temperature (FIG 1) and as "9:00" of radiant temperature (FIG 2).
It seems there is a slide of 1 hour. How should I interpret this?
Kind regards,
artemátyika…
Added by artemátyika at 3:34pm on February 2, 2019
in the desired order.
0 = 0
1 = 1
2 = 6
3 = 7
4 = 8
5 = 9
6 = 12
7 = 13
8 = 2
9 = 3
10 = 4
11 = 5
12 = 10
13 = 11
Where the first number is the index and the second number is the actual sorting key. Then you sort these keys while sorting your curves in parallel using the A input of the Sort component.
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
nts (where 2 are null). Why is it so that there is only this list of points output?
The problem is that I generate only one polyline of the X division wanted!
How can I fix that?
Thanks for your help...
Sam…