I manually filtered with equality component the panels, but I would like to avoid to review manually each value, since changing the number of panels the value change.
thanks in advance!…
you can open the studyFolder (it's one of the outputs of run daylight analysis component.) and check *.bat files. There is a rpict or rtrace line that you can see all the parameters listed. Mine is:
rpict -i -t 10 -vtv -vp 43.111 -74.673 49.782 -vd -0.433 0.750 -0.500 -vu 0.000 0.000 1.000 -vh 54.328 -vv 26.991 -vs 0.000 -vl 0.000 -x 64 -y 64 -af unnamed_IMG.amb -ps 8 -pt 0.15 -pj 0.6 -dj 0 -ds 0.5 -dt 0.5 -dc 0.25 -dr 0 -dp 64 -st 0.85 -ab 2 -ad 20 -as 128 -ar 16 -aa 0.001 -lr 4 -lw 0.050 -av 0 0 0 unnamed_IMG.oct > unnamed_IMG.unf
aa and ad values are changed in this example.
Mostapha
…
para poder parametrizarla - Entender cómo se gestionan los datos con Grasshopper - Asociar formulaciones matemáticas a modelos paramétricos - Panelizar y triangular superficies - Parametrizar estructuras sencillas - Saber deformar modelos tridimensionales paramétricamente - Elaboración de algoritmos simples y aplicarlos a modelos tridimensionales - Exportar e importar tablas de datos
El curso será impartido por dos Authorized Rhino Trainers.
También te informamos de que hemos renovado el temario del curso, preparado específica y exclusivamente por nosotros, y que es revisado y ampliado continuamente, gracias a la experiencia de cursos anteriores. El curso tiene un formato intensivo de 18 horas, cuyo horario es: - viernes, de 16 a 20; - sábado, de 10 a 14 y de 16 a 20; - domingo, de 11 a 14 y de 16 a 19.
Si estás interesado en apuntarte, contáctanos en: cursos@frikearq.com…
angle has to be between 5° to 15°
-for color 2, the angle has to be between 20° to 30°
etc..
Can I subdivided the surface by type of color (exemple: color 1 will be 2 subdivision; color 2 will be 3 subdivision, ..)
many many thx for your help guys :)
…
ny iterations at one go as you describe:
http://smartgeometry.org/index.php?option=com_community&view=groups&task=viewdiscussion&topicid=20&groupid=2&Itemid=0
I also posted there an example of linking this to Galapagos - which is something I'd been meaning to explore more for ages. I've not tried it yet with anything more interesting than adjusting the depth of a truss to minimize total displacement, but I think there's a lot more that could be done.…
ay how many valid permutations exist.
But allow me to guesstimate a number for 20 components (no more, no less). Here are my starting assumptions:
Let's say the average input and output parameter count of any component is 2. So we have 20 components, each with 2 inputs and 2 outputs.
There are roughly 35 types of parameter, so the odds of connecting two parameters at random that have the same type are roughly 3%. However there are many conversions defined and often you want a parameter of type A to seed a parameter of type B. So let's say that 10% of random connections are in fact valid. (This assumption ignores the obvious fact that certain parameters (number, point, vector) are far more common than others, so the odds of connecting identical types are actually much higher than 3%)
Now even when data can be shared between two parameters, that doesn't mean that hooking them up will result in a valid operation (let's ignore for the time being that the far majority of combinations that are valid are also bullshit). So let's say that even when we manage to pick two parameters that can communicate, the odds of us ending up with a valid component combo are still only 1 in 2.
We will limit ourselves to only single connections between parameters. At no point will a single parameter seed more than one recipient and at no point will any parameter have more than one source. We do allow for parameters which do not share or receive data.
So let's start by creating the total number of permutations that are possible simply by positioning all 20 components from left to right. This is important because we're not allowed to make wires go from right to left. The left most component can be any one of 20. So we have 20 possible permutations for the first one. Then for each of those we have 19 options to fill the second-left-most slot. 20×19×18×17×...×3×2×1 = 20! ~2.5×1018.
We can now start drawing wires from the output of component #1 to the inputs of any of the other components. We can choose to share no outputs, output #1, output #2 or both with any of the downstream components (19 of them, with two inputs each). That's 2×(19×2) + (19×2)×(19×2-1) ~ 1500 possible connections we can make for the outputs of the first component. The second component is very similar, but it only has 18 possible targets and some of the inputs will already have been used. So now we have 2×(18×2-1) + (18×2-1)×(18×2-1) ~1300. If we very roughly (not to mention very incorrectly, but I'm too tired to do the math properly) extrapolate to the other 18 components where the number of possible connections decreases in a similar fashion thoughout, we end up with a total number of 1500×1300×1140×1007×891×789×697×...×83×51×24×1 which is roughly 6.5×1050. However note that only 10% of these wires connect compatible parameters and only 50% of those will connect compatible components. So the number of valid connections we can make is roughly 3×1049.
All we have to do now is multiply the total number of valid connection per permutation with the total number of possible permutations; 20! × 3×1049 which comes to 7×1067 or 72 unvigintillion as Wolfram|Alpha tells me.
Impressive as these numbers sound, remember that by far the most of these permutations result in utter nonsense. Nonsense that produces a result, but not a meaningful one.
EDIT: This computation is way off, see this response for an improved estimate.
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
Added by David Rutten at 12:06pm on March 15, 2013
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…