ecember 2017 from 18:30 until 20:30. We will have presentations from Heatherwick Studio and AKT II.
Please visit the following page for more details and registration: http://simplyrhino.co.uk/events/upcoming-events/grasshopper-uk-ugm-2017
Heatherwick studio will present two projects covering the topic of designing, making and collaborating through computational tools. Heatherwick’s Geometry and Computational Design team will go through the computational processes behind design and making in the studio concentrating on two projects, Vessel in New York with a focus on driving the geometry and Al Fayah Park in Abu Dhabi with a focus on Form Finding and working with collaborative tools.
AKT II's presentation will explore a series of examples where this new approach was experimented, tested and improved, the Al Fayah Park in collaboration with Heatherwick studio and the 2016 Serpentine Pavilion with BIG, and more.
We're looking forward to seeing you all again!
Many thanks,
Paul and Arthur
…
heating? Or cooling?)
What if you have 20C? You need to heat to 24-26?
What if you have 28? Then you cool to 24-26?
Something is missing here ...
Or am i wrong? (In this case i don't understand the logic).
Besides that, you are simulating 3 zones instead of 1. Your conncetions of all the HB_setEPZoneSchedules to the HB_setEPIdealAir is causing this. Messy ... a little bit.
-A.…
: Castellano
Horarios
Básico - miércoles
18.30 - 21.30 h
Avanzado - miércoles
15.00 - 18.00 h
Una vez finalizado el curso, el alumno podrá solicitar un diploma acreditativo del mismo.
Normativa: http://daetsam.aq.upm.es/servicios/cursos/informacion
Información cursos: http://daetsam.aq.upm.es/servicios/cursos/primavera2014
Métodos de pago: http://daetsam.aq.upm.es/noticias/2014/02/16/cursos-primavera-2014-aplicaciones-informaticas-e-idiomas
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
s than 40% on average.2. 8gb usage is steady at 28% 3. I've been now looking at 2 blank white screen, in both Rhino and Grasshopper for well over 20 min. finally I went for a walk at 10:25am, (its a beautiful day why waste it looking at nonexistent calculations, It would help if there was a timing function in the code that would let me know how long the calculations were going to take, came back 11:25am still no results. Had to Quit Rhino in the Start manager.
I have used all sorts of window programs for well over 25 years. Rhino and Grasshopper are the only 2 programs that I have ever seen that show totally white screens in their operating windows :(
…
to select a period of time across the year, for example, every hour from January 1 to June 30.
I currently use DOY/HOY to assign the analysis period (basically I want to run 8760 hours), and connect its HOY to DAY_MONTH_HOUR_CALCULATOR. Then, connect it to CB sky. But, there are several warnings pop-up on the component "DOY/HOY", says Feb. has 28 days, the date is corrected by Ladybug, and as well as other months less than 31 days. After the HOY is connected to the "DAY_MONTH_HOUR_CALCULATOR", the warnings are gone, and the lines become green. However, when I connect the "DAY_MONTH_HOUR_CALCULATOR" to CB sky, the output of "sky file pate" turns orange again. This causes the repetition of the last day of those months less than 31 days.
(I attach a picture for your information)
Does any of you know how to solve this problem? And what is the best way to run annual hourly (8760 hours) with CB sky?
Many thanks in advance!!
Wenhsin…