NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
s than 40% on average.2. 8gb usage is steady at 28% 3. I've been now looking at 2 blank white screen, in both Rhino and Grasshopper for well over 20 min. finally I went for a walk at 10:25am, (its a beautiful day why waste it looking at nonexistent calculations, It would help if there was a timing function in the code that would let me know how long the calculations were going to take, came back 11:25am still no results. Had to Quit Rhino in the Start manager.
I have used all sorts of window programs for well over 25 years. Rhino and Grasshopper are the only 2 programs that I have ever seen that show totally white screens in their operating windows :(
…
l equations that describe his attractor in a chaotic behavior when rho > 24.7. All the values of X =sigma(Y-X) *dt never repeat themselves through each moment in time making their distribution totaly random, we can see this at the end of the video with the linear graph. The beautiful thing is that even though the values of X are randomly distribuited over time, the result is a beautiful ordered shape, this in essence is the principal of chaotic systems. Or as James Gleick would say " chaotic systems embed hidden ordering principles"
X =sigma(Y-X)
Y= -X*Z+rho*X-Y
Z = X*Y-betta*Z
X = dx/dt -------> change of X over time
Y = dy/dt -------> change of Y over time
Z= dz/dt -------> change of z over time
rho = 28
betta = 3/8
sigma = 10
http://mathworld.wolfram.com/LorenzAttractor.html…
another comma separated txt file. I know how to import points (function Import coordinates), but I dont know how to connect them by lines if the only information I have about lines is the list of point numbers which should be connected. The txt file with point coordinates looks like:
-18,-36,-1000-18,-34,-19.728-18,-32,-17.603-18,-30,-15.372-18,-28,-13.121
...
And the txt file with line connections looks like:
1,22,33,44,55,6
...
Which means that I want to connect point 1 with point 2, point 2 with point 3 etc...
Both txt files are attached, thank you for the answer...…
思った感じになりません。
balls の代わりにplanarカーブを直接入れてみましたがエラーが出ます。
ファンクションにしてみたところ、forループので作った数値が反映されていません。
ファンクションのインスタンス?を出力していないと思い上記のようにしましたがエラーが出てしまいます。
以上の事から自分の認識が正しいのかよくわからなくなりました・・・
python自体の深いところをわかっているわけではないので余計こんがらがりました。
そこで、for b in ballsはどのような条件または使い方であれば使えるのでしょうか?
そして、上記のように別のオブジェクトに対しての使い方はどのようにすればできるのでしょうか?
2:同じファンクション内のdist = rs.Distance(self.pos,b.pos)についてですが
この文章も for b in balls によってbはBallのインスタンスであると定義?されたためb.posがbの位置であると分かるのでしょうか?
pythonは定義しなくても動いてしまうのでどのような時に使えるのか文章見ただけではよくわかりません・・・
大変細かいことかもしれませんが、よりpythonをしっかりと理解するためにも、どなたかわかる方ご教授いただけると幸いです。…