another comma separated txt file. I know how to import points (function Import coordinates), but I dont know how to connect them by lines if the only information I have about lines is the list of point numbers which should be connected. The txt file with point coordinates looks like:
-18,-36,-1000-18,-34,-19.728-18,-32,-17.603-18,-30,-15.372-18,-28,-13.121
...
And the txt file with line connections looks like:
1,22,33,44,55,6
...
Which means that I want to connect point 1 with point 2, point 2 with point 3 etc...
Both txt files are attached, thank you for the answer...…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
ions! == fantastic.
1. When at begin = false mode > (a) you can now see things and (b) you can reduce your panels (prior the interactive massacre,i.e. begin = true) based on the famous algo of mine as written in this top secret (C)(tm) function:
MassacreOnList(sListSorted, pC, CofCPanelDist) : in Plain English:: take no prisoners.
2. make a break > buy a book (you know what kind) > learn things > sky is the limit (in fact events/delegates is the limit - nasty stuff).
3. in order to get your def (the complete thing) YOU MUST post here a hymn (original, lyrical and passionate) related with the ultimate thing: my Panigale 1199.
best, Lord Of Darkness
…
e structure systems. It presents an algorithmic process where the initial generative rule is based on the growth of Cellular Automata (CA). Digital Fabrication techniques will be used for prototyping. Theoretical lectures about Cellular Automata, Generative design and fabrication techniques will be presented .
Duration : 21 June. – 28 June. 2013 from 10 am to 6 pm Location : ENCODE Studio Address: 2 Wataneya buildings , 14 May Bridge , Smouha , Floor 1 , Apartment 106 Tel: 03-3823637 Mob: 0100-9879995 Email: encodestudio.mail@gmail.com Website: www.encodestudio.net for more information and registration please fill the following form : https://docs.google.com/forms/d/1FC9-CIDsNuzMkmu3Rubj45_7zTBb6YB3OfYnEA9xOMk/viewform?edit_requested=true Attendance Confirmation email will be sent to confirm availability…
schi (Authorized Rhino Trainer) tutor: Maurizio Arturo Degni
La simulazione fisica interattiva, integrata nell’ambito della modellazione parametrica consente di indagare nuove soluzioni formali ottimizzate per l'architettura ed il design. Il workshop approfondirà le strategie e le principali tecniche di FORM FINDING utilizzando il motore fisico KANGAROO integrato a plugin di analisi strutturale (MILLIPEDE). Le tecniche saranno applicate a diversa scala: dall'architettura (modellazione di superfici e coperture a semplice compressione) al design del prodotto, dove la simulazione digitale sarà integrata a tecniche di refinement (WEAVERBIRD). Il workshop e rivolto a studenti e professionisti con conoscenze base di modellazione tridimensionale. Sarà rilasciato un attestato di partecipazione firmato da Arturo Tedeschi in qualità di Authorized Rhino Trainer.
…
Compatibility with Monolith
Issue
Peregrine users may experience an error on a PC that already has Autodesk Monolith installed:
Solution exception:Unable to load DLL 'LSFORMInterface.dll': The operati
ceros. Parametrización, panelización y análisis en Grasshopper, así como el proceso de manufactura digital para maquinaria de corte Láser y CNC.
UN solo pago anticipado $4,000.00
Pagos diferidos $4,500.00*
*reserva tu lugar con el 50%
Martes y Jueves de 7 a 10 PM
Del 15 de Mayo al 14 de junio
DURACION: 30 HORAS
SESIONES: 10 DE 3 HORAS
o info@dimensiontallerdigital.com
informes al 55 (50 16 0634) con Mayri Gallegos (o al cel. 55 28 85 24 73)
$4,000.00…
.components as ghimport karamba
I have copied all the folder named '64bit' in grasshopper library folder (items are not in a sub-folder). The karamba.py gives me back an in-script error, i.e.
Runtime error (ImportException): No module named _karambaTraceback:line 20, in swig_import_helper, "C:\Users\Claudio\AppData\Roaming\Grasshopper\Libraries\karamba.py"line 28, in <module>, "C:\Users\Claudio\AppData\Roaming\Grasshopper\Libraries\karamba.py"line 2, in script
Just wondering if I could have an help about this. I tried the IronPython example, but it keeps saying that the karamba.gha does not exist in my plugin folder (but it's there). This occurs on line 3 of your example on the operation clr.AddReferenceToFileAndPath(*the path it finds*)
Many thanks
Claudio…