lass BrepDeform Inherits GH_Component Public Reslist As New List(Of String) Public Sub New() MyBase.New("BrepDeform", "Deform", _ "移动物件的控制点" & vbCrLf & "(Move the control Point to change a object)", "SEG", "Modify")
End Sub Public Overrides ReadOnly Property ComponentGuid As System.Guid Get Return New Guid("8226e0ea-ed6b-47c2-8a24-244f044152d8") End Get End Property Protected Overrides ReadOnly Property Internal_Icon_24x24() As System.Drawing.Bitmap Get Return My.Resources.SEG_BrepDeform End Get End Property Protected Overrides Sub RegisterInputParams(ByVal pManager As GH_Component.GH_InputParamManager) ' pManager.AddTextParameter("Guid", "Id", "将要被替换的犀牛物件" & vbCrLf & "(RhinoObjects that will be replaced)", GH_ParamAccess.item) 'Dim guidParam As New Param_Guid pManager.AddParameter(New Param_Guid, "Guid", "Id", "将要被替换的犀牛物件" & vbCrLf & "(RhinoObjects that will be replaced)", GH_ParamAccess.item) pManager.AddPointParameter("ControlPoint3d", "C", "控制点的位置" & vbCrLf & "(Control Point's location)", GH_ParamAccess.item) pManager.AddPointParameter("NewPoint3d", "P", "新控制点的位置" & vbCrLf & "(New Control Point's location)", GH_ParamAccess.item) pManager.AddNumberParameter("Tolerace", "T", "输入点与物件实际控制点对比的精度" & vbCrLf & "(Tolerace for the Control Point match)", GH_ParamAccess.item, 0.1)
pManager.AddBooleanParameter("BlMove", "M", "如果是True则进行移动" & vbCrLf & "(If true Perform the Move)", GH_ParamAccess.item, False)
End Sub Protected Overrides Sub RegisterOutputParams(ByVal pManager As Kernel.GH_Component.GH_OutputParamManager) pManager.AddTextParameter("Result", "RG", "结果列表" & vbCrLf & "(Result)", GH_ParamAccess.list) End Sub Public Overrides ReadOnly Property Exposure As GH_Exposure Get Return GH_Exposure.primary End Get End Property
Protected Overrides Sub SolveInstance(ByVal DA As Kernel.IGH_DataAccess) If Banner.astrict.showmessage Then Return Dim Ids As Guid = Guid.Empty 'Dim Ids As String = String.Empty Dim tpt As Point3d = Point3d.Unset, opt As Point3d = Point3d.Unset Dim tolar As Double = 0.1 Dim blMove As Boolean = False If Not DA.GetData(0, Ids) Then Return If Not DA.GetData(1, opt) Then Return If Not DA.GetData(2, tpt) Then Return If Not DA.GetData(3, tolar) Then Return If Not DA.GetData(4, blMove) Then Return If Not blMove Then GoTo line1 Reslist.Add(Now & "_未替换!(Replace failed!)") Else Reslist.Clear() ' Grasshopper.Instances.ActiveCanvas.ModifiersEnabled = False End If
' rt.AddRange(docobjlist.Select(Function(geoobj As RhinoObject) GH_Convert.ObjRefToGeometry(New ObjRef(geoobj.Id)))) 'Private Checked(5) As Boolean, Namestr() As String = {"Point", "Curve", "Brep", "Mesh", "TextDot", "TextEntity"}
Try
Dim rh As RhinoDoc = Rhino.RhinoDoc.ActiveDoc Dim rhobj As RhinoObject = rh.Objects.Find(Ids) ' Dim rhobj As RhinoObject = rh.Objects.Find(New Guid(Ids))
Dim bobj As BrepObject = CType(rhobj, BrepObject) RhinoApp.RunScript("Cancel", False) RhinoApp.RunScript("Cancel", False) bobj.Select(True)
RhinoApp.RunScript("_SolidPtOn", False) Dim gobjs As GripObject() = bobj.GetGrips ' rh.Views.RedrawEnabled = False For Each grpobj As GripObject In gobjs
If grpobj.CurrentLocation.DistanceTo(opt) < tolar Then grpobj.Select(True) Dim CurrentPln As Plane = RhinoDoc.ActiveDoc.Views.ActiveView.ActiveViewport.ConstructionPlane Dim tropt As New Point3d(opt), trtpt As New Point3d(tpt) tropt.Transform(Transform.PlaneToPlane(Plane.WorldXY, CurrentPln)) trtpt.Transform(Transform.PlaneToPlane(Plane.WorldXY, CurrentPln))
Dim movestr As String = "_move " + String.Format("{0},{1},{2} ", tropt.X, tropt.Y, tropt.Z) + String.Format("{0},{1},{2} _Cancel _Cancel", trtpt.X, trtpt.Y, trtpt.Z) RhinoApp.RunScript(movestr, True) grpobj.Select(False) End If
Next
'RhinoApp.RunScript("Cancel", False) 'RhinoApp.RunScript("Cancel", False) '' rh.Views.RedrawEnabled = True Reslist.Add(Now & "_替换成功!(Replace Success!)") Catch ex As Exception Reslist.Add(Now & "_替换失败!(Replace failed!)" & vbCrLf & ex.Message)
End Try ' Grasshopper.Instances.ActiveCanvas.ModifiersEnabled = True
line1: DA.SetDataList(0, Reslist) End Sub
'Private Sub Testt_PingDocument(sender As IGH_DocumentObject, e As GH_PingDocumentEventArgs) Handles Me.PingDocument ' Dim Mbool = Aggregate bcbool In Checked Into cb = Any(bcbool)
' If Not Mbool Then ' Checked(0) = True ' Message = Namestr(0) ' Order = 0 ' End If 'End Sub
End Class
The picture below shows the two question.
Question One I must use data dam, or the component can't batch deal the brep. I don't know why, I have You can give me a solution to make it working normal not using the data dam
Question Two I can not uset the Button component, If I use it, the gh canvas will die with some mouse event--. I have see this problem before in this forum,but there is no solution and explain. I want to know why and How to solve it.
I don't know if I have made my question clear,if not give a message. Thank you! Thank you all.
The gh test file and 3dm test file in the upload files.
…
ectural project, the efficiency of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
lane that looks like the outline of a gear wheel
2. Scale a bunch of copies of the curve to different sizes (I use 11 different sized curves.)
3. Move each curve vertically to a different Z-height
4. Rotate each curve to get the desired wavy/wiggly effect
5. Create a Loft surface using all the curves.
A critical step when creating the Loft is to add the curves in order - either top to bottom or bottom to top.
Step 4 can be omitted if you want a constant curvature throughout the final part. In this case all you have to do is Twist by the desired amount the Loft surface made from un-rotated curves. …
Added by Birk Binnard at 2:18pm on October 15, 2016
ings" [every person on the experiment is one ring] which show the time duration. The outer sphere is divided in 11 segments [which are basically the segments of a human brain] I hav imported the data so far but what i aim is to find a way to connect each moment[time, second] from the inner sphere to a number of points from a specific segment in the outer. For example for Person number1, at 5th second the segments that are activated are 4th , 6th, 11th with 2, 3, 2 points.
It could be done manually but since the connections are a few thousands and i got the lists, i wonder whether there is a better way.
Any help is appreciated, i do not attach files since you need the excel files aswell. If anyone would like to help i can email the files.
Thanks in advance.…
elated with the Topology outputs:
So let's try to do (via components) the face reconstruction stage (the missing 4 as above):
Alias crenelatedEdgesTree as polylineTree.
Imagine a Lst that samples all the edges per Face ("changed" and "unchanged") as Curves.
1. Let's take face 3: this is surrounded by edges 10,11,12,13 and 37.
2. Has edge 10 "changed" (to polyline) ? No because in the polylineTree there's no branch {10} ... thus sample edge 10 from the EList (Note: apparently that's a boundary edge). Has edge 11 "changed" ? No ... blah, blah.
3. Has edge 12 "changed" ? Yes because in the polylineTree there's a branch {12} ... thus sample the item from that branch. Same for 13 ... etc etc.
4. Thus we have sampled all the surrounding edges as Curves and the next step is to join them > yielding a closed Curve.
5. Then we must "planarize" that Curve (by projecting it into the corresponding Brep Face plane) ... and the rest are history.
So ... try it and report any issue encountered.…
Target group The workshop is fully funded and is addressed to students of architecture and civil engineering faculties at master level from Estonia (11 seats), Latvia (3 seats), Lithuania (3 seats) and Sweden (3 seats). The selected students will have full scholarship that will include travel, board and lodging in Tallinn for 10 days (arrival on Sunday 03.07.2016 departure on Wednesday 13.07.2016). The workshop is funded by the NORDPLUS programme of the Nordic Council of Ministers (NCM) - Higher Education objective.
Description The use of digital and computational design tools is increasingly important for the activity of design and research for architects and engineers. It permits to integrate environmental and energy aspects from the very early stages of the design and planning process to achieve more performative, efficient and integrated buildings and urban environments. The workshop attendants will broaden their design and technical knowledge with solar design, daylighting and energy efficiency topics and will learn how to integrate environmental analysis and building performance analysis tools with parametric and generative methodologies in architecture and planning.
Location
Tallinn University of Technology – Departments of Structural Design and Environmental Engineering
Dates
From 04 to 12 July 2016
Workshop blog
For detailed program, info and registration visit the blog at ceedtut.blogspot.com
In the weeks just before the workshop the blog will present also materials and tutorials to get a basic knowledge of the topics prior to the beginning of the workshop.
…
Visiting School Rio de Janeiro will collaborate with the Centro Carioca de Design with the support of Columbia University Studio X to investigate new possibilities for the urban infrastructure surrounding World Cup Stadiums. Nation-wide, there has been significant investment to build and renovate stadiums for the 2014 World Cup in order to meet the required standard FIFA regulations (‘Padrão FIFA’). At the same time, there has been a large public demand for equal investment into transport systems, public space, and public programs such as hospitals and schools. The Visiting School will tap into the momentum of this movement, and promote a series of interventions within and around the World Cup structures, proposing new public programs and standards for their legacy. Students can choose to focus directly on the Maracanã stadium in Rio de Janeiro, the venue for the Final match of the World Cup. The intense ten-day workshop will employ computational design and digital fabrication to introduce a design methodology that creatively automates and promotes transformation, mutation and complexity for these infrastructure interventions.
Prominent Features of the workshop
Teaching teamThe teaching team will include a mix of tutors from the Architectural Association, including Theodore Sarantoglou Lalis e Dora Sweijd (lassa-architects.com) of Diploma 17, and locally-based architects, urban-designers and experts, mediated by locally-based Visiting School directors, to promote cutting-edge innovative strategies informed by local political, economic and construction issues.
Computational skillsThe workshop will teach advanced digital modeling and parametric design skills, no previous experience is needed. A group of specialist computation tutors will conduct an initial skills workshop and continue to assist throughout the workshop to develop the individual projects of the participants.
Digital FabricationA series of physical models will be built using digital fabrication techniques that will be taught during the workshop, no previous experience is needed.
Applications
1) You can make an application by completing the online application found under ‘Links and Downloads’ on the AA Visiting School page. If you are not able to make an online application, email visitingschool@aaschool.ac.uk for instructions to pay by bank transfer.
2) Once you complete the online application and make a full payment, you are registered to the programme. A CV or a portfolio is not required.
The deadline for applications is 11thApril 2014.
All participants travelling from abroad are responsible for securing any visa required, and are advised to contact their home embassy early. After payment of fees, the AA School can provide a letter confirming participation in the workshop.
Fees
The AA Visiting School requires a fee of £695 per participant, which includes a £60 Visiting membership fee.
Fees do not include flights or accommodation, but accommodation options can be advised. Students need to bring their own laptops, digital equipment and model making tools. Please ensure this equipment is covered by your own insurance as the AA takes no responsibility for items lost or stolen at the workshop.
Eligibility
The workshop is open to current architecture and design students, phd candidates and young professionals.
…
para poder parametrizarla - Entender cómo se gestionan los datos con Grasshopper - Asociar formulaciones matemáticas a modelos paramétricos - Panelizar y triangular superficies - Parametrizar estructuras sencillas - Saber deformar modelos tridimensionales paramétricamente - Elaboración de algoritmos simples y aplicarlos a modelos tridimensionales - Exportar e importar tablas de datos
El curso será impartido por dos Authorized Rhino Trainers.
También te informamos de que hemos renovado el temario del curso, preparado específica y exclusivamente por nosotros, y que es revisado y ampliado continuamente, gracias a la experiencia de cursos anteriores. El curso tiene un formato intensivo de 18 horas, cuyo horario es: - viernes, de 16 a 20; - sábado, de 10 a 14 y de 16 a 20; - domingo, de 11 a 14 y de 16 a 19.
Si estás interesado en apuntarte, contáctanos en: cursos@frikearq.com…
be done easier, but later on the geometry will change and therefore this seems the better option. But coming back to the problem
First, there were some problems concerning the zone, although it seems solved still the “runenergysimulation” gives the following warning:
1. The simulation has not run correctly because of this severe error:
** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature
Do one of you know what went wrong? It probably will solve most of it.
Second, “set Zone Thresholds” gives the following warning:
1. Solution exception:global name 'maxHumidity_' is not defined
However, the component is missing the max humidity input on the list, has this to do something with the error?
All the components are up to date.
I hope it will be an easy fix.
Gr Lars
“set Zone Thresholds” runtime error
{0;0;0}0. Runtime error (UnboundNameException): global name 'maxHumidity_' is not defined1. Traceback: line 80, in checkTheInputs, "<string>" line 282, in script
"runenergysimulation” report
{0;0}0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. TypeError('Waarde kan niet null zijn.\r\nParameternaam: source',)3. Failed to copy the object. Returning the original objects...This can cause strange behaviour!4. [1 of 8] Writing simulation parameters...5. [2 of 8] No context surfaces...6. [3 of 8] Writing geometry...7. [4 of 8] Writing Electric Load Center - Generator specifications ...8. [5 of 8] Writing materials and constructions...9. [6 of 8] Writing schedules...10. [7 of 8] Writing loads and ideal air system...11. [8 of 8] Writing outputs...12. ...... idf file is successfully written to : c:\ladybug\unnamed\EnergyPlus\unnamed.idf13. 14. Analysis is running!...15. c:\ladybug\unnamed\EnergyPlus\eplusout.csv16. ......
Done! Read below for errors and warnings:
17. 18. Program Version,EnergyPlus, Version 8.3.0-6d97d074ea, YMD=2016.03.02 20:55,IDD_Version 8.3.019. 20. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.21. 22. ************* Beginning Zone Sizing Calculations23. 24. ** Warning ** GetInternalHeatGains: People="CLASSROOMOFFICEPEOPLE", Activity Level Schedule Name values25. 26. ** ~~~ ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.27. 28. ** ~~~ ** Odd comfort values may result; Schedule="SCHOCCUPANCYSCHEDULE".29. 30. ** ~~~ ** Entered min/max range=[0.0,1.0] W/person.31. 32. ** Warning ** Calculated design heating load for zone=CLASSROOM is zero.33. 34. ** ~~~ ** Check Sizing:Zone and ZoneControl:Thermostat inputs.35. 36. ** Severe ** UpdateZoneSizing: Cooling supply air temperature (calculated) within 2C of zone temperature37. 38. ** ~~~ ** ...check zone thermostat set point and design supply air temperatures39. 40. ** ~~~ ** ...zone name = CLASSROOM41. 42. ** ~~~ ** ...design sensible cooling load = 25499.10 W43. 44. ** ~~~ ** ...thermostat set point temp = 0.000 C45. 46. ** ~~~ ** ...zone temperature = 15.334 C47. 48. ** ~~~ ** ...supply air temperature = 15.000 C49. 50. ** ~~~ ** ...temperature difference = -0.33433 C51. 52. ** ~~~ ** ...calculated volume flow rate = 197273.21341 m3/s53. 54. ** ~~~ ** ...calculated mass flow rate = 237634.19357 kg/s55. 56. ** Warning ** ManageSizing: For a plant sizing run, there must be at least 1 Sizing:Plant object input. SimulationControl Plant Sizing option ignored.57. 58. ************* Testing Individual Branch Integrity59. 60. ************* All Branches passed integrity testing61. 62. ************* Testing Individual Supply Air Path Integrity63. 64. ************* All Supply Air Paths passed integrity testing65. 66. ************* Testing Individual Return Air Path Integrity67. 68. ************* All Return Air Paths passed integrity testing69. 70. ************* No node connection errors were found.71. 72. ************* Beginning Simulation73. 74. ************* Simulation Error Summary *************75. 76. ** Warning ** The following Report Variables were requested but not generated77. 78. ** ~~~ ** because IDF did not contain these elements or misspelled variable name -- check .rdd file79. 80. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL COOLING ENERGY, Frequency=Hourly81. 82. ************* Key=*, VarName=ZONE PACKAGED TERMINAL HEAT PUMP TOTAL HEATING ENERGY, Frequency=Hourly83. 84. ************* Key=*, VarName=CHILLER ELECTRIC ENERGY, Frequency=Hourly85. 86. ************* Key=*, VarName=BOILER HEATING ENERGY, Frequency=Hourly87. 88. ************* Key=*, VarName=FAN ELECTRIC ENERGY, Frequency=Hourly89. 90. ************* Key=*, VarName=ZONE VENTILATION FAN ELECTRIC ENERGY, Frequency=Hourly91. 92. ************* Key=*, VarName=EARTH TUBE FAN ELECTRIC ENERGY, Frequency=Hourly93. 94. ************* Key=*, VarName=PUMP ELECTRIC ENERGY, Frequency=Hourly95. 96. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT LOSS ENERGY, Frequency=Hourly97. 98. ************* Key=*, VarName=ZONE VENTILATION TOTAL HEAT GAIN ENERGY, Frequency=Hourly99. 100. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE COOLING ENERGY, Frequency=Hourly101. 102. ************* Key=*, VarName=EARTH TUBE ZONE SENSIBLE HEATING ENERGY, Frequency=Hourly103. 104. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.105. 106. ************* EnergyPlus Sizing Error Summary. During Sizing: 3 Warning; 1 Severe Errors.107. 108. ************* EnergyPlus Completed Successfully-- 5 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 4.65sec109.…
TB of RAM. I think I'm going to start a GoFundMe campaign to buy one for myself :)
2- The server's cost is about $13 an hour. I get free access to supercomputer through my university and xsede.org because I earned an NSF Honorable mention last March, however, the supercomputers available through both resources are a little complicated for me to use, as opposed to the one available from amazon that has Microsoft server 2012 already installed.
3- I wanted to run 400 annual glare simulations for 400 different views.
4- I tried a to perform annual glare simulation for one view on my Dell XPS that has Intel Core i7-6700HQ processor and 16GB of system memory. The simulation took 2 hours to complete. Radiance parameter ab was set to 6.
5- I wanted to obtain the batch file for each view so I can run them on the server. So I used the fly component to run all 400 simulations and closed the cmd windows, that wasn't bad ( for me at least) because I asked my son to this job for me, he was just glad to help me :)
6- I created one batch file using this cmd command:
dir /s /b *.bat > runall.bat
This created a file with the path to each .bat file. I edited this file in Notepad++ to include the word "start" at the beginning of each line. This was done using the "find and replace" dialogue box.
7- I split my newly created batch file into 3 batch files, each one has about 130 file names and " start" before the file names.
8- installed radiance on my server
9- Ran the first batch file on the server, this started 130 cmd windows performing my simulations, CPU usage was anywhere between 90% to 100% and about 105 GB of RAMs were used.
10. It took about 5 hours to complete all 130 simulations, I expected to run all in 2 hours but can't complain because this would've taken about 260 hours to run on my laptop. After the simulations done I ran the second and then the third batch files ( total of about 15 hours).
11. I got 400 valid dgb files. Couldn't be happier!
…