ed according to list C.
I tried replace members, but it consists of geometry, so it doesn't worked.
In list C I filtered all the indices that need to be replaced.
All items in {0;0} from C need to be replaced by List B {0;0}
All items in {0;1} from C need to be replaced by List B {0;1}
And so on...
In the end everything needs to be fed into a orient component.
G is the geometry behind list B
A is the new list (but I don't know how to create)
B is the list A of all 60 panels
To wrap up the question:
I need to have entry 1 from list B in a new list on position: 0 1 2 3 5 6 7 10 11 12 15 16 21
I need to have entry 2 from list B in the same new list on position: 4 8 9 13 14 etc. etc. etc.
I wonder how I can do this :) Thanks in advance!
…
掌握编程过程中遇到的思路方面和技术方面的问题. 内容包括以下几个方面:
反向逻辑思维能力的培养;
建立清晰的编程逻辑思维能力;
GH 的程序设计理念;
并行数据结构深入理解和控制.
Grasshopper course of McNeel Asia focus on the cultivation of students flexible use of programming techniques, the ability to solve practical problems. Our course deep into the whole process of programming, from programming thinking model, the components principle to usage details do detailed explanation, help students complete mastery programming encountered in the process of thinking and technical aspects, include the following content:
Ability of reverse logical thinking;
Establishment of clear programming logical thinking ability;
The program design concept of Grasshopper;
Understanding parallel data tree structure and how to control it.
更多详细内容... More details…
授课讲师 Instructor 课程由Grasshopper原厂McNeel公司在中国地区的两位 Rhino 原厂技术推广工程师 – Dixon、Jessesn联合授课。课程结束后对达到授课预定目标的学员颁发唯一由Grasshopper原厂认证的结业证书.
Dixon & Jessesn, McNeel Asia Support engineer, by the end of course student who achieve the intended target will get the authentication certificate from McNeel Asia.
课程报名 Register this course 课程即日开始报名, 开课一周前停止报名, 名额满提前报名结束. This course begin to sign up, stop sign up a week ago, with the quota ahead over.
在线报名参加课程...
Sign up to this course…
课程日期 Schedule 7/15-7/20 Beijing 北京 7/26-7/31 Shanghai 上海 7/07-7/12 Shenzhen 深圳
课程范例演示 Samples of Grasshopper course demo
Note: pls follow below comments by Jessesn to see the samples…
Pérez Albà McNeel Europe presents Rhino 5.0, Matus Nedecký (flying architecture) and Fabio Palvelli (3D Dreaming) show VRAY for Rhino and rendering services for architecture. We also show the new Wacom Cintiq 22 HD touch.
There are 2 events, the first at 15:00 and the second at 18:30. Places are limited to 30 people each.
As a special event you can switch between the events at a basic coffee seminar "Coffee - from the plant to the cup" part. Coffee Museum in Austrian society and economy museum was founded by Edmund Mayr, who injected together with Arch Wilhelm Holzbauer, the increase of the flak tower in Esterhazy Park. His passion for collecting are also due to the many exhibits that he has collected from all over the world. Additionally Mag. Just shows a quick roundup of "100 Years of Life and Living in Vienna" and how the inventions of Dr. Carl Auer von Welsbach changed the world significantly.
program: 15:00 to 15:45 Presentation software Autodesk Maya 2014 (group 1)
15:45 -. 16:00 Tour "100 years of life and living in Vienna / Dr Carl Auer von Welsbach in the Agricultural Museum (Group 1)
16:00 to 16:45 Presentation software Rhino 5.0 and VRAY (group 1)
5:00 p.m. to 6:15 p.m. basic coffee seminar "Coffee - from the plant to the cup" with Mr Edmund Mayr
18:30 to 19:15 Presentation software Autodesk Maya 2014 (Group 2)
19:15 -. 19:30 Tour "100 years of life and living in Vienna / Dr Carl Auer von Welsbach in the Agricultural Museum (Group 1)
19:30 to 20:15 Presentation software Rhino 5.0 and VRAY (Group 2)
20:15 finger found, drinks and "Come Together"
22:00 End of the event
Participation is FREE, due to the limited number of places but registration is required. To register for the event, we ask you to select the following options:
Online Registration 15:00 http://www.kkkc.at/component/seminar/?task=3&cid=5
Online Registration 18:30 http://www.kkkc.at/component/seminar/?task=3&cid=6
or by email: office@kkkc.at
or Tel: 01-545 78 25…
Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…
square units. Then you have an integral number of fragments on each side. This means that if all fragments need to have the same surface area, you can only have the following possibilities for side A:
1 fragment = 100 square units
2 fragments = 50 square units each
3 fragments = 33⅓ square units each
4 fragments = 25 square units each
5 fragments = 20 " "
6 fragments = 16⅔ " "
etc.
For side B, the numbers are mostly different
1 fragment = 300 unit²
2 fragments = 150 unit²
3 fragments = 100 unit²
4 fragments = 75 unit²
For side C they are different still. Unless you join fragments across on both sides of the edges of the box, I very much doubt you'll be able to pull this off.
The solution I attached will create fragments as identical as possible, but it's a very boring outcome...
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
9 8 7 6
5 4 3 2 1 0
I am triangulating this surface. I want to select just the red vertices. As you can note, I just need the inner vertices of this surface. I could do it mannually, but if I want to change the mesh density later, I will have to pick all of them manually again later.
Can someone help me?
Tks
…
ce attractors
3- Relation between mathematics and Form
4- Network surface and Paneling
5- Fabrication methods (slice3d, nesting, ...)
6- Structure and Architecture (Millipede)
7-Energy and form
8- Islamic patterns
9- Physics with kangaroo
…
I extract the first two with a "Redim Preserve t(1)" command.
In the first case, the redim is correct, Line 7 = Line 2 and Line 8 = Line 3. It just kept the first two values like it is supposed to be.
But, for the second curve starting Line 9, some t values are messed up after the Redim. Line 16 = Line 17 despite Line 11 was different from Line 12. That's what is creating a problem later in the Split.
Weird.
…
12
z=2, f=14
z=3, f=16
for y=3
z=0, f=..... etc etc etc
I have created the GH algorithm (attached), but I have trouble to run all the values of z range for y, before going to y+1 (loop in a loop). Do I have to set it up in VB?
Thanks in advance…