us. Here I would use catchment component instead.
Apart from this; considering you want to assign any value to a number of objects: you have 28 locations (corresponding to circles) and 78 values! What do you want to do? 28*78 different objects (circles)? If so you need to graft the point input of circle component. What sense would it make; I do not see!
…
which doesn't exist in the actual problem spec. If galapagos is allowed to change the column position in all possible directions, it is less likely to get stuck in some local optimum.
Let's assume that (all other things being equal) column 20 would yield the best possible answer. The current state of the system though is at column 26, which is pretty good too, just not as good. Galapagos is more likely to 'mutate' the state a little bit instead of a lot, so it'll explore the columns near 26. However 20 isn't near 26 at all, only 25 and 27 are nearby, and maybe 24 and 28. But they'll all worse answers, so after sampling in those directions GP will abandon that as fruitless.
If however you specify the columns using two variables, then the columns near 26 are 20, 25, 27 and 32. That's a far richer space to explore which much better approximates the real problem.…
David,
Apologies for the delay in posting the sample files. Put together a more up to date set of samples. They are attached to this comment.mesh%28%2B%29-Samples.zip
Simple question. I just want to get the 15 greatest values from a list of 28 elements... some of them have the same value though (see image attached)
THX
New Series! Vaults! Get to learn how to generate various types of Vaults! Don't forget to like, subscribe and share! Cheers!0:00 Intro0:36 Start1:28 Arches G...
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…