TB of RAM. I think I'm going to start a GoFundMe campaign to buy one for myself :)
2- The server's cost is about $13 an hour. I get free access to supercomputer through my university and xsede.org because I earned an NSF Honorable mention last March, however, the supercomputers available through both resources are a little complicated for me to use, as opposed to the one available from amazon that has Microsoft server 2012 already installed.
3- I wanted to run 400 annual glare simulations for 400 different views.
4- I tried a to perform annual glare simulation for one view on my Dell XPS that has Intel Core i7-6700HQ processor and 16GB of system memory. The simulation took 2 hours to complete. Radiance parameter ab was set to 6.
5- I wanted to obtain the batch file for each view so I can run them on the server. So I used the fly component to run all 400 simulations and closed the cmd windows, that wasn't bad ( for me at least) because I asked my son to this job for me, he was just glad to help me :)
6- I created one batch file using this cmd command:
dir /s /b *.bat > runall.bat
This created a file with the path to each .bat file. I edited this file in Notepad++ to include the word "start" at the beginning of each line. This was done using the "find and replace" dialogue box.
7- I split my newly created batch file into 3 batch files, each one has about 130 file names and " start" before the file names.
8- installed radiance on my server
9- Ran the first batch file on the server, this started 130 cmd windows performing my simulations, CPU usage was anywhere between 90% to 100% and about 105 GB of RAMs were used.
10. It took about 5 hours to complete all 130 simulations, I expected to run all in 2 hours but can't complain because this would've taken about 260 hours to run on my laptop. After the simulations done I ran the second and then the third batch files ( total of about 15 hours).
11. I got 400 valid dgb files. Couldn't be happier!
…
d additionally (again)..the value for diffuse radiation is assigned as a % of the direct-normal radiation..(see attached image #2).
So, my assumption is that the entire radiation data set of 8760*2 values is based out of just 7 empirically measured values. All of this still doesn't explain why the plot will turn out that way. I think I have figured out a bug. I will put that in a separate post..
…
is the best way to create 100 batch files, one for each view?
The only thing I can think of is to create a list of the names of my views and connect it to "list item component" then animate the item index slider. However, each time the slider moves simulation starts then I close the Dos window to get a batch file, this means I have to close 100 windows (one at a time). Is there any way Honeybee can write batch files without running simulations.
2- I read somewhere that Radiance uses 1 processor, Does this means that I can run all 100 batch files simultaneously on a server that has at least 100 CPUs and get results in a speedy manner?
Thanks
Rania
…
I would now like to do is "combine" (only count once) the panels that are stacked vertically between the domain. (I've only got 3 surfaces selected to cut down on the confusion)The domain is the horizontal lines on the object to the ground plane. so Level 1 is 0-8'-7 3/4". Level 2 is 8'-7 3/4" - 15'-3 3/4". ect.
The approach is that the panels that are stacked on top of each other have the same x,y coordinate so they can be separated and counted as 1 instance in the final count.
I started trying to deconstruct the points and create sets of each x and y value but I've got no idea where to go from there. Any have any ideas?
Excel File being referenced looks like this:
Ground
0
1
8.6458
2
15.0625
3
22.375
4
28.5
5
35.333
6
42.2708
…
radiance parameters to get rid of blotching. To add another level of complexity to my problem, I am running simulations with a translucent material with the following properties: void trans testTrans
0
0
7 0.478 0.478 0.478 0.000 0.010 0.178 0.635
I have had no issues with the renderings when I use clear glazing, as seen on this image:
However the blotching-issue becomes very noticeable when I introduce translucent glazing into the scene:
For the two above cases I used the following parameters:
_av_ is set to 0
xScale is set to 2
_ab_ is set to 6
_dc_ is set to 0.5
_aa_ is set to 0.2
_ad_ is set to 2048
_st_ is set to 0.5
yScale is set to 2
_ps_ is set to 4
_ar_ is set to 64
_as_ is set to 2048
_ds_ is set to 0.25
_pt_ is set to 0.1
_dr_ is set to 1
_pj_ is set to 0.9
_dp_ is set to 256
_dt_ is set to 0.25
_lr_ is set to 6
_dj_ is set to 0.5
_lw_ is set to 0.01
I ran another test with increased Radiance parameters and got the following output:
with the following parameters:
_av_ is set to 0
xScale is set to 6
_ab_ is set to 6
_dc_ is set to 0.75
_aa_ is set to 0.1
_ad_ is set to 4096
_st_ is set to 0.15
yScale is set to 6
_ps_ is set to 2
_ar_ is set to 128
_as_ is set to 4096
_ds_ is set to 0.05
_pt_ is set to 0.05
_dr_ is set to 3
_pj_ is set to 0.9
_dp_ is set to 512
_dt_ is set to 0.15
_lr_ is set to 8
_dj_ is set to 0.7
_lw_ is set to 0.005
Although the second blotching case is much better than the first, it is still very bad for hours when the sun is lower in the sky. The above images are rendered for a clear sky at 18:00 in Germany in a West-facing room.
Sorry for the long post! Can someone help? Kind regards, Örn
…
cy of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
ectural project, the efficiency of design communication and the control of information-flow are as important as the creativity of ideas. In response to the concurrent digital evolution emerging in the architectural industry world-wide, the Faculty of Architecture at The University of Hong Kong will host a two week intensive summer program named Digital Practice.Led by professors from The University of Hong Kong, as well as invited practitioners with expertise in practice of cutting edge digital techniques, the program offers participants opportunities to experience applications of computational tools during different stages of an architectural project, i.e. concept design, form finding and optimization, delivery, management and communication of design information under the team-based working environment. By learning advanced computational techniques through case studies in the context of Hong Kong, participants are expected to go beyond the conventional perception of technology, considering users and tools as a feedback-based entity instead of a dichotomy. The program, which is taught in English, includes a series of evening lectures related delivered by teaching staff and invited local architects.對於高品質的建築專案,創意之外,專案過程中高效的設計資訊管理和交流成為項目設計深化和實施必不可少的環節。今天,數字化技術不但改變了建築師的繪圖工具,影響了設計的過程,而且提供了工程建造和管理實施的更有效、更高效的手段。針對建築的數位化演進,香港大學建築學院將於2011年暑假期間,在香港大學建築學院舉辦“數位化實踐”國際研習班。在香港大學建築學院教授及有著相關豐富經驗的外聘實踐建築師的指導下,學員將有機會體驗在專案的不同階段(如概念設計、設計形式的生成、優化,設計資訊的管理和交流),如何有效地應用各種運算智慧化技術(從設計的數位化生成和建築資訊類比到物理模型),提升設計實施的品質,增加設計團隊對於方案的控制。我們將挑戰對於“技術”的傳統認知,即相對於使用者它不僅是工具,更是與使用者互動的媒介,二者形成一個有機的合體。研習班期間會安排系列講座,展現數位化技術在實踐工程中的廣泛應用。…
nd) group you have an MD Slider. When you move the point on the grid you see that the values change in the yellow panel output for list items index 1 & 2.
I would like to find a method to not change the values, but add a new index and list item for each change made with MD slider. I'm fully aware of the fact that this would generate a tremendous amount of data.
When I eventually have a list with 128, 256, 512 or maybe 1024 items, I would like to create a line with these values as points.
Though, making the line from values is no prob, I've already done that with the series and range components.
There must be a way of storing numbers in some kind of buffer somewhere, or what? I know I could save my data from pd as a file and import it in grasshopper, but the nice thing with the udp/osc connection is the realtime exchange.
Also, I could write a VB/C# script, but before I spend several weeks learning and implementing this, I figured I'd ask here because there simply HAS to be some easier way to do it, like a check box that says 'keep values' or something. As I said, it's noob question... oh well.
Thanks for any help, it's driving me nuts.…
GH, same as using sweep2 command in Rhino.
The one on the right is what I got so far (the output smooth our the kink of the original rails). Basically I am just following the methods provided by sdk sample: http://wiki.mcneel.com/developer/sdksamples/sweep2 .
The following is the function I copy and use directly from the SDK sample. By using this function, I can generate the sweep surface at right. But I want to have is the one in the middle with the kink edges. Can anyone show me how and where to modify he settings? I guess some sweep arguments need to be changed? I have try couples, such m_simplify, m_bSimpleSweep, m_bSameHeight, m_rebuild_count... but still cannot find a right combination for this function to output the sweep surface I want. Any suggestions or helps are very appreciated. Thanks for your help and time on this.
'Sweep2 function'----------------
Sub Sweep2( ByVal Rail1 As IOnCurve, _
ByVal Rail2 As IOnCurve, _
ByVal sCurves As List(Of IOnCurve), _
ByRef Sweep2_Breps As List(Of OnBrep))
'Define a new class that contains sweep2 arguments
Dim args As New MArgsRhinoSweep2
'Set the 2 rails
Dim Edge1 As New MRhinoPolyEdge
Dim Edge2 As New MRhinoPolyEdge
Edge1.Append(Rail1.DuplicateCurve())
Edge2.Append(Rail2.DuplicateCurve())
'Add rails to sweep arguments
args.m_rail_curves(0) = Edge1
args.m_rail_curves(1) = Edge2
args.m_bClosed = False
Dim section_curves As New List(Of OnCurve)
'Loop through sections to set parameters
For Each Section As IOnCurve In sCurves
Dim sCurve As OnCurve = Section.DuplicateCurve()
section_curves.Add(sCurve)
Dim t0 As Double = 0
If Not Edge1.GetClosestPoint(sCurve.PointAtStart(), t0) Then
If Not Edge1.GetClosestPoint(sCurve.PointAtEnd(), t0) Then
Dim s As Double = 0
sCurve.GetNormalizedArcLengthPoint(0.5, s)
Edge1.GetClosestPoint(sCurve.PointAt(s), t0)
End If
End If
args.m_rail_params(0).Append(t0)
Dim t1 As Double = 0
If Not Edge2.GetClosestPoint(sCurve.PointAtStart(), t1) Then
If Not Edge2.GetClosestPoint(sCurve.PointAtEnd(), t1) Then
Dim s As Double = 0
sCurve.GetNormalizedArcLengthPoint(0.5, s)
Edge2.GetClosestPoint(sCurve.PointAt(s), t1)
End If
End If
args.m_rail_params(1).Append(t1)
Next
'Set shapes
args.m_shape_curves = section_curves.ToArray
'Set the rest of parameters
args.m_simplify = 0
args.m_bSimpleSweep = False
args.m_bSameHeight = False
args.m_rebuild_count = -1 'Sample point count for rebuilding shapes
args.m_refit_tolerance = RMA.Rhino.RhUtil.RhinoApp.ActiveDoc.AbsoluteTolerance()
args.m_sweep_tolerance = RMA.Rhino.RhUtil.RhinoApp.ActiveDoc.AbsoluteTolerance()
args.m_angle_tolerance = RMA.Rhino.RhUtil.RhinoApp.ActiveDoc.AngleToleranceRadians()
Dim sBreps() As OnBrep = Nothing
If (RhUtil.RhinoSweep2(args, sBreps)) Then
For Each b As OnBrep In sBreps
Sweep2_Breps.Add(b)
Next
End If
Return
End Sub
…