ches it with the first branch in Tree B (and then the first branch in Tree C if more than two trees are involved).
I'm planning to add better branch matching logic, but I'm not going to touch it until I have a good idea about what's needed and how it can be accomplished without breaking existing files.
So, the branch "address" is only used to sort the branches in a single tree. Thus, a tree with the following branches is always sorted in the exact same way:
{0;0}
{0;1}
{0;2}
{0;3;0}
{0;3;1}
{1;6}
If you have another tree with different branches:
{0}
{1}
{2}
{3}
{4}
{5}
Then the matching will be:
{0;0} -> {0}
{0;1} -> {1}
{0;2} -> {2}
{0;3;0} -> {3}
{0;3;1} -> {4}
{1;6} -> {5}
As long as people adhere to your advice: "it is best for the addresses of each tree branch to be in the same format", there will be no problem. But it is at the moment extremely difficult to perform complex matchings.
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
Added by David Rutten at 9:25am on August 11, 2010
rated by "<" symbols. Examples: "2<10", "2<4<10", "Pow(2, 1)<5*Sin(3)<10".
The entered text contains 2 or 3 segments separated by two or more consecutive dots. Examples "2..10", "2..4..10", "Pow(2, 1)....5*Sin(3)..10".
If only two segments are provided, then the initial value will be the same as the minimum value. If a bounds number or a default value is written as a simple number, then the number of decimal places will be harvested. I.e. "2..4..10" is not the same as "2..4..10.00" as the former will result in an integer slider and the latter in a slider with two decimal places.
--
David Rutten
david@mcneel.com
Poprad, Slovakia…
Added by David Rutten at 10:08am on February 15, 2013
Pérez Albà McNeel Europe presents Rhino 5.0, Matus Nedecký (flying architecture) and Fabio Palvelli (3D Dreaming) show VRAY for Rhino and rendering services for architecture. We also show the new Wacom Cintiq 22 HD touch.
There are 2 events, the first at 15:00 and the second at 18:30. Places are limited to 30 people each.
As a special event you can switch between the events at a basic coffee seminar "Coffee - from the plant to the cup" part. Coffee Museum in Austrian society and economy museum was founded by Edmund Mayr, who injected together with Arch Wilhelm Holzbauer, the increase of the flak tower in Esterhazy Park. His passion for collecting are also due to the many exhibits that he has collected from all over the world. Additionally Mag. Just shows a quick roundup of "100 Years of Life and Living in Vienna" and how the inventions of Dr. Carl Auer von Welsbach changed the world significantly.
program: 15:00 to 15:45 Presentation software Autodesk Maya 2014 (group 1)
15:45 -. 16:00 Tour "100 years of life and living in Vienna / Dr Carl Auer von Welsbach in the Agricultural Museum (Group 1)
16:00 to 16:45 Presentation software Rhino 5.0 and VRAY (group 1)
5:00 p.m. to 6:15 p.m. basic coffee seminar "Coffee - from the plant to the cup" with Mr Edmund Mayr
18:30 to 19:15 Presentation software Autodesk Maya 2014 (Group 2)
19:15 -. 19:30 Tour "100 years of life and living in Vienna / Dr Carl Auer von Welsbach in the Agricultural Museum (Group 1)
19:30 to 20:15 Presentation software Rhino 5.0 and VRAY (Group 2)
20:15 finger found, drinks and "Come Together"
22:00 End of the event
Participation is FREE, due to the limited number of places but registration is required. To register for the event, we ask you to select the following options:
Online Registration 15:00 http://www.kkkc.at/component/seminar/?task=3&cid=5
Online Registration 18:30 http://www.kkkc.at/component/seminar/?task=3&cid=6
or by email: office@kkkc.at
or Tel: 01-545 78 25…
owing error has been raised: System.Runtime.InteropServices.COMException (0x80040154): Retrieving the COM class factory for component with CLSID {CE7E6869-6F74-4E9D-9F07-3DCBADAB6299} failed due to the following error: 80040154 没有注册类 (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)). at System.Runtime.Remoting.RemotingServices.AllocateUninitializedObject(RuntimeType objectType) at System.Runtime.Remoting.Activation.ActivationServices.CreateInstance(RuntimeType serverType) at System.Runtime.Remoting.Activation.ActivationServices.IsCurrentContextOK(RuntimeType serverType, Object[] props, Boolean bNewObj) at System.RuntimeMethodHandle.InvokeMethod(Object target, Object[] arguments, Signature sig, Boolean constructor) at System.Reflection.RuntimeConstructorInfo.Invoke(BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture) at Microsoft.Scripting.Interpreter.NewInstruction.Run(InterpretedFrame frame) at Microsoft.Scripting.Interpreter.Interpreter.Run(InterpretedFrame frame) at Microsoft.Scripting.Interpreter.LightLambda.Run3[T0,T1,T2,TRet](T0 arg0, T1 arg1, T2 arg2) at System.Dynamic.UpdateDelegates.UpdateAndExecute2[T0,T1,TRet](CallSite site, T0 arg0, T1 arg1) at Microsoft.Scripting.Interpreter.DynamicInstruction`3.Run(InterpretedFrame frame) at Microsoft.Scripting.Interpreter.Interpreter.Run(InterpretedFrame frame) If upper error is:1) "Retrieving the COM class factory for component with CLSID…" then try the following fix: a) Close Rhino. Restart your PC. Once the PC boots up, double click on the "regMapWinGIS.cmd" file in "MapWinGIS" installation folder. When it closes the Command Prompt window it opened, try running Rhino, Grasshopper and the component again. b) If the upper COM class error appears again, then close Rhino, and uninstall the MapWinGIS application. It is advisable to do that with an application which does that by removing not only the installation files but also the leftover files (like those from registry). For example, use the: Revo Uninstaller Pro. A free 30 days full working version can be downloaded from: http://www.revouninstaller.com. After the Revo Uninstaller Pro uninstalls MapWinGIS, install it again, but this time by running the installation file by right clicking on it, and choosing: Run as -> Administrator. After the installation is complete double click on "regMapWinGIS.cmd" file in "MapWinGIS" installation folder. When it closes the Command Prompt window it opened, try running Rhino, Grasshopper and the component again. If after this the COM class error appears again, then post a question about this issue at: http://www.grasshopper3d.com/group/gismo/forum. 2) If the upper error is not "Retrieving the COM class factory for component with CLSID…", please post a question about this issue at:http://www.grasshopper3d.com/group/gismo/forum.…
Added by Elise to Gismo at 6:11am on November 13, 2019
That is correct. In reality there are 3 major versions of .NET 1, 2, and 4 (different versions of mscorlib.dll)
Rhino 4 uses .NET 2 which includes 3 and 3.5.
Rhino 5 uses .NET 4