NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
tably Scale to Area and Scale to Volume components. Many other additions, options, and outputs added to previous components. General optimizations and fixes all around. Some component rearrangements in the tabs. Some components require at least Rhino 5 SR12. After installing the pufferfish1-8.gha, please close Rhino completely one time to avoid potential assembly reference errors with the "Twisted Box" components.…
the message in attachment, then i asked for the "No admin version", but when i launched the istaller, i received the message in attach, and the sofware has not been istalled. ( I tried also to copy WeaverBird.rhp onto a running instance of Rhinoceros) but nothing happened. So something goes wrong, but i don't know what. Could someone help me?
THX…
number of divisions on that curve as in the defintion (i.e. by 4). The offset in the def is slightly different and should cull two or three more curves as in the lists that show my aim below.
Basically I want to look into each branch of the groups of points from each closed curve . Marking in a list whether it contains a one or a zero (0= outside 1 = coincidents).
{0;0}0. 21. 22. 23. 2 {0;1} 0. 01. 22. 03. 2 {0;2}0. 01. 02. 03. 0 {0;3}0. 21. 22. 23. 2 {0;4}0. 21. 22. 23. 2 {0;5}0. 21. 22. 23. 2 {0;6}0. 01. 22. 23. 1 {0;7}0. 21. 22. 03. 0 {0;8}0. 21. 22. 23. 2 {0;9}0. 21. 22. 23. 2 {0;10}0. 21. 22. 23. 2 {0;11}0. 21. 22. 23. 2 {0;12}0. 21. 22. 23. 2 {0;13}0. 01. 22. 23. 0 {0;14}0. 21. 22. 23. 2
I want to create a list from these points. That marks each curve that pokes out, in a cull pattern as such:
20022210222202
Using a 1 where there are co-incidents in the curve points and the boundary. A 2 for true (outside points) and a 0 for containment. So I might be able to use the 1 in future developments - however if a true false list is easiest I can live with that.
So could I use F(x) function? - to look for 0 or 1's in each bunch of points and thus list as such for a cull pattern? or will Path mapper help me here? Or can I rely on simply grafting and splitting??
I am usure of the neatest solution and would love to learn. Hope you can direct me.rgrds
J.…
hopper...without a crash
Shows Rhino Loading @ 0:00 - memory stable
Grasshopper Loading @ 0:29 - memory begins to rise to 90%+
Memory dumped to disk after double click on canvas and stabilises @ 1:46
Place Pop 3D component @ 1:47 Close file - Memory runs away@ 2:56
repeat above steps double click doesn't dump this time whilst memory is on the rise. @ 3:09
memory dumps and stabilises after deleting a component @ 4:00
close file @ 4:29
Repeat with more geometry to try higher stress on CPU
Memory dump and stabilises with no corresponding GH interface actions. @ 6:13…
TB of RAM. I think I'm going to start a GoFundMe campaign to buy one for myself :)
2- The server's cost is about $13 an hour. I get free access to supercomputer through my university and xsede.org because I earned an NSF Honorable mention last March, however, the supercomputers available through both resources are a little complicated for me to use, as opposed to the one available from amazon that has Microsoft server 2012 already installed.
3- I wanted to run 400 annual glare simulations for 400 different views.
4- I tried a to perform annual glare simulation for one view on my Dell XPS that has Intel Core i7-6700HQ processor and 16GB of system memory. The simulation took 2 hours to complete. Radiance parameter ab was set to 6.
5- I wanted to obtain the batch file for each view so I can run them on the server. So I used the fly component to run all 400 simulations and closed the cmd windows, that wasn't bad ( for me at least) because I asked my son to this job for me, he was just glad to help me :)
6- I created one batch file using this cmd command:
dir /s /b *.bat > runall.bat
This created a file with the path to each .bat file. I edited this file in Notepad++ to include the word "start" at the beginning of each line. This was done using the "find and replace" dialogue box.
7- I split my newly created batch file into 3 batch files, each one has about 130 file names and " start" before the file names.
8- installed radiance on my server
9- Ran the first batch file on the server, this started 130 cmd windows performing my simulations, CPU usage was anywhere between 90% to 100% and about 105 GB of RAMs were used.
10. It took about 5 hours to complete all 130 simulations, I expected to run all in 2 hours but can't complain because this would've taken about 260 hours to run on my laptop. After the simulations done I ran the second and then the third batch files ( total of about 15 hours).
11. I got 400 valid dgb files. Couldn't be happier!
…