wever, when I copy the cluster, all the wires come out of the output (there's about 10 of them) and need to be re-inserted.
As the completed structure requires 19 subframes, doing it this way will require a lot of tedious rewiring.
Does anyone know if there is an easier way of repeating a subframe to form a complete structure.
Picture of current Grasshopper model shown below.
141105lm%20-%20JLR%20Grasshopper%20Model.jpg
Cheers
Luke…
Added by Luke Murley at 4:06am on November 5, 2014
and GH 0.6.0057. I notice that from your JPEG the components name is Diff and mine would be SDiff if I had text view on. Have you got the latest version?
EDIT: I've just looked in the file and you are using 0.6.0019
#item name="plugin_version" type_name="gh_version" type_code="80">
#Major>0
#Minor>6
#Revision>19
#/item>
Try with the latest WIP: http://www.grasshopper3d.com/forum/topics/grasshopper-060059-available
Danny…
Added by Danny Boyes at 8:32am on January 12, 2010
ipants from 12 countries to attend lectures and technical seminars furthering their understanding of digital design and fabrication in architecture. This year LaN extends the workshop with parallel intro sessions in all LAN ports–Barcelona / Boulder / Brooklyn / Bozeman (Aug 10-12). In 2009, you choose your modules.
Register Online
*please note, participants who have previously attended a LaN workshop automatically get a discount of total price.
Key Dates:
June 1, 2009: Workshop Launch - Applications Open @ 10% off price
June 19, 2009: Workshop Applications Open at 5% off
July 10, 2009: Applications open
August 7, 2009: Applications Closed
August 10-12, 2009: PHASE I - Modules [North America and Barcelona]
August 16-22, 2009: PHASE II - Modules [Barcelona @ IaaC / Institute for advanced architecture of Catalonia ]
August 24-30, 2009: PHASE III - Urban Drifts Workshop [Barcelona @ IaaC / Institute for advanced architecture of Catalonia]
*please note: all Rhino courses will be taught by a Rhino Certified Trainer
PHASE I: Aug 10-12
Phase I will be conducted in parallel in BARCELONA / BOULDER / BROOKLYN / BOZEMAN and are meant to familiarize participants with software and techniques. Phase I registration is inclusive of both module 1 & 2.
1. Rhino Introduction - 12hrs
2. RhinoFab: Rhino + Fabrication - 12hrs
PHASE II: Aug 17 - 22
Phase II modules will take place at the Institute for Advanced Architecture of Catalonia [IaaC] in Barcelona, Spain and will deal with scripting, parametric design and fabrication provided by FabLab BCN.
3. RhinoScript - 20hrs
4. Parametric Modelling in Rhino: Grasshopper - 20hrs
5. Introduction to Digital Fabrication - 20hrs
6. Machining Processes- 20hrs
PHASE III: Aug 24-30 ‘Urban Drifts’ Workshop - 40hrs
Register Online
Contact: bcn2@livearchitecture.net
More Information: http://www.livearchitecture.net…
m facing some issues.
The code I wrote is the following, trying to retreive the Modulus of Elasticity of one element:
private void RunScript(object x, ref object A) {
Karamba.Models.Model model = (Karamba.Models.Model) x; A = model.elems[0].crosec.material.E(); }
With Karamba 1.3.0 properly assembled.
I'm getting the following errors:
1. Warning (CS1701): Assuming assembly reference 'RhinoCommon, Version=6.1.18037.13441, Culture=neutral, PublicKeyToken=552281e97c755530' matches 'RhinoCommon, Version=6.3.18090.471, Culture=neutral, PublicKeyToken=552281e97c755530', you may need to supply runtime policy
2. Warning (CS1701): Assuming assembly reference 'Grasshopper, Version=6.1.18037.13441, Culture=neutral, PublicKeyToken=dda4f5ec2cd80803' matches 'Grasshopper, Version=6.3.18090.471, Culture=neutral, PublicKeyToken=dda4f5ec2cd80803', you may need to supply runtime policy
1. [A]Karamba.Models.Model cannot be cast to [B]Karamba.Models.Model. Type A originates from 'karamba, Version=1.14.0.0, Culture=neutral, PublicKeyToken=null' in the context 'LoadNeither' in a byte array. Type B originates from 'karamba, Version=1.14.0.0, Culture=neutral, PublicKeyToken=null' in the context 'LoadFrom' at location 'C:\Program Files\Rhino 6\Plug-ins\karamba.gha'. (line: 116)
Looks like a problem between Karamba 1.3.0 and Rhino 6 assembles. Any ideia to solve this? I need to update my exiting scripts since they all stopped working.
…
nowledge, tools, materials and machines. The Clusters provide a focus for workshop participants working together within a common framework.
Clusters provide a forum for the exchange of ideas, processes and techniques and act as a catalyst for design resolution. The Workshop is made up of ten Clusters that respond in diverse ways to the sg2012 Challenge Material Intensities. The Call for Clusters is now open to proposals which respond in innovative ways to this year's challenge.
Deadline: September 19 2011
More information can be found here:
http://smartgeometry.org/index.php?option=com_content&view=article&id=129&Itemid=146
sg2012 takes place from 19-24 March 2012 at EMPAC (http://empac.rpi.edu/) and is hosted by Rensselaer Polytechnic Institute in Troy, upstate New York USA. The Workshop and Conference will be a gathering of the global community of innovators and pioneers in the fields of architecture, design and engineering.
The event will be in two parts: a four day Workshop 19-22 March, and a public conference beginning with Talkshop 23 March, followed by a Symposium 24 March. The event follows the format of the highly successful preceding events sg2010 Barcelona and sg2011 Copenhagen.
sg2012 Challenge Material Intensities
Simulation, Energy, Environment
Imagine the design space of architecture was no longer at the scale of rooms, walls and atria, but that of cells, grains and vapour droplets. Rather than the flow of people, services, or construction schedules, the focus becomes the flow of light, vapour, molecular vibrations and growth schedules: design from the inside out.
The sg2012 challenge, Material Intensities, is intended to dissolve our notion of the built environment as inert constructions enclosing physically sealed spaces. Spaces and boundaries are abundant with vibration, fluctuating intensities, shifting gradients and flows. The materials that define them are in a continual state of becoming: a dance of energy and information.Material potential is defined by multiple properties: acoustical, chemical, electrical, environmental, magnetic, manufacturing, mechanical, optical, radiological, sensorial, and thermal. The challenge for sg2012 Material Intensities is to consider material economy when creating environments, micro-climates and contexts congenial for social interaction, activities and organisation. This challenge calls for design innovation and dialogue between disciplines and responsibilities.sg2010 Working Prototypes strove to emancipate digital design from the hard drive by moving from the virtual to the actual in wrestling with the tangible world of physical fabrication. sg2011 Building the Invisible focused on informing digital design with real world data. sg2012 Material Intensities strives to energise our digital prototypes and infuse them with material behaviour. They have the potential to become rich simulations informed by the material dynamics, chemical composition, energy flows, force fields and environmental conditions that feed back into the design process.
More information can be found at http://www.smartgeometry.org…
terior wall. I disconnected this air wall and the model runs fine I ran it for 19 generations for over the period of 7 hours.
2. Earlier, when I ran the model with air wall connected to altConstruction_, I observed that in the middle of this optimization process, one or many zones will disappear altogether from rhino scene and that is when the results became undefined. In the image you attached, if you see in the top left corner, zone Commercial 1F is missing. I witnessed a similar behavior. This disappearance of zones may explain the erratic highs and lows in fitness numbers that you are talking about.
3. I also made a few changes in how you apply glazing ratios. Please find file with changes.
4. My results are attached as well. When I used air wall as altConstruction, the model ran for 7 generations and then started displaying errors as I mentioned in my earlier responses. After removing air wall and making a change in how glazing ratio is applied, the model ran successfully for 19 generations.
Hope this helps,
Devang
…
NONE, in SIZING:PARAMETERS". I'm not sure of where to start in troubleshooting this. I've attached the file.
Thank you,
See the errors and warnings below:
{0;0;0}
0. Current document units is in Meters
1. Conversion to Meters will be applied = 1.000
2. [1 of 8] Writing simulation parameters...
3. [2 of 8] Writing context surfaces...
4. [2 of 8] Writing context surfaces...
5. [3 of 8] Writing geometry...
6. [4 of 8] Writing Electric Load Center - Generator specifications ...
7. [5 of 8] Writing materials and constructions...
8. [6 of 8] Writing schedules...
9. [7 of 8] Writing loads and ideal air system...
10. [8 of 8] Writing outputs...
11. ...
... idf file is successfully written to : R:\Green\SuRG\Building_Performance_Analysis\2016_analysis_studies\Energy_Analysis_Comparison\Honeybee_+_Ladybug\tutorial01\EnergyPlus\tutorial01.idf
12.
13. Analysis is running!...
14. ...
...
Done! Read below for errors and warnings:
15.
16. Program Version,EnergyPlus, Version 8.5.0-c87e61b44b, YMD=2016.10.31 11:39,IDD_Version 8.5.0
17.
18. ************* IDF Context for following error/warning message:
19.
20. ************* Note -- lines truncated at 300 characters, if necessary...
21.
22. ************* 24 Sizing:Parameters,
23.
24. ************* Only last 1 lines before error line shown.....
25.
26. ************* 25 None, !- Heating Sizing Factor
27.
28. ** Severe ** IP: IDF line~25 Invalid Number in Numeric Field#1 (Heating Sizing Factor), value=NONE, in SIZING:PARAMETERS
29.
30. ** Warning ** IP: Note -- Some missing fields have been filled with defaults. See the audit output file for details.
31.
32. ** ~~~ ** Possible Invalid Numerics or other problems
33.
34. ** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination.
35.
36. ...Summary of Errors that led to program termination:
37.
38. ..... Reference severe error count=1
39.
40. ..... Last severe error=IP: IDF line~
, value=NONE, in SIZING:PARAMETERS
41.
42. ************* Warning: Node connection errors not checked - most system input has not been read (see previous warning).
43.
44. ************* Fatal error -- final processing. Program exited before simulations began. See previous error messages.
45.
46. ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
47.
48. ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
49.
50. ************* EnergyPlus Terminated--Fatal Error Detected. 1 Warning; 1 Severe Errors; Elapsed Time=00hr 00min 9.34sec
51.…
pattern on your surface,then you must also adjust the voronoi pattern.by the way, when you select your surface and click to the details-button (Properties), then you can see the properties of your surface.NURBS Surface"U": degree =3 CV count = 4 (0 <= U <= 41.3728)"V": Periodic degree =3 CV count = 19 (0 <= V <= 16)
maybe try to understand the def from "Natsuo Nakajima"?
that could take you further!…
o connect the 'Line' for ClampLength and how it relating to Lower- and UpperLimitation.
they have differently lower and upper limitation configuration between red/blue (L:10; U: 10000000) and yellow/green(L:3; H:19)...are those parameter meaning something..?
It would be nice if you could explain about that ;-)
Otherwise, awesome example!
…
Added by Jon to Kangaroo at 3:27am on May 23, 2016