nput parameter and then set the named values on the second?
protected override void BeforeSolveInstance() { Param_Integer param0 = Params.Input[0] as Param_Integer; Param_Integer param1 = Params.Input[1] as Param_Integer; param1.ClearNamedValues();
GH_Structure<GH_Integer> data = param0.VolatileData as GH_Structure<GH_Integer>; if (data.IsEmpty) return; foreach (GH_Integer value in data.AllData(true)) { switch (value.Value) { case 1: param1.AddNamedValue("First option for 1", 11); param1.AddNamedValue("Second option for 1", 12); param1.AddNamedValue("Third option for 1", 13); break;
case 2: param1.AddNamedValue("First option for 2", 21); param1.AddNamedValue("Second option for 2", 22); param1.AddNamedValue("Third option for 2", 23); break;
case 3: param1.AddNamedValue("First option for 3", 31); param1.AddNamedValue("Second option for 3", 32); param1.AddNamedValue("Third option for 3", 33); break; } return; } }
--
David Rutten
david@mcneel.com…
Added by David Rutten at 1:56am on December 18, 2013
ards to the number before the start number...
i.e. 9, 0, 1, 2, 3, 4, 5, 6, 7, 8
then it will need to repeat this pattern (continuing to count upwards) and the repeat number is based on a slider (for example 3 in the case illustrated below):
9, 0, 1, 2, 3, 4, 5, 6, 7, 8
19, 10, 11, 12, 13, 14, 15, 16, 17, 18,
29, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29,
if anyone has any ideas on how to create this series it would be great
M.…
etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc. "
except in data, the branches start at 0, so 'group 1' is branch 0
as for the order of your points, that depends on the input prior sorting...
yrs …
ns would be handy for Permutation Animations where multiple variables can be sequenced for better visualizations
Say we have 3 variables, A = 1- 100 : B = 50 - 600 : C = 100-200
Animation start with A=1, B=50 and C goes from 100-200 : then A=1, B=51 and C = 100-200 and once B gets to 600, A turns to 2... and so forth
And doing this manually takes a lot of time...
…
EC
1. Between hours 1:00 to 24:002. Current document units is in Meters3. Conversion to Meters will be applied = 1.0004. [1 of 7] Writing simulation parameters...5. [2 of 6] No context surfaces...6. [3 of 6] Writing geometry...7. [4 of 6] Writing materials and constructions...8. [5 of 7] Writing schedules...9. [6 of 7] Writing loads and ideal air system...10. [7 of 7] Writing outputs...11. ...... idf file is successfully written to : c:\ladybug\Freeformtower_IDF\EnergyPlus\Freeformtower_IDF.idf12. 13. Analysis is running!...14. ......
Done! Read below for errors and warnings:
15. 16. Program Version,EnergyPlus-Windows-64 8.1.0.009, YMD=2015.04.04 23:39,IDD_Version 8.1.0.00917. 18. ************* IDF Context for following error/warning message:19. 20. ************* Note -- lines truncated at 300 characters, if necessary...21. 22. ************* 577 Zone,23. 24. ************* Only last 1 lines before error line shown.....25. 26. ************* 578 Freeformbuilding27. 28. ** Warning ** IP: IDF line~578 Comma being inserted after:" Freeformbuilding" in Object=ZONE29. 30. ** Severe ** Out of range value Numeric Field#5 (Type), value=0.00000, range={>=1 and <=1}, in ZONE=FREEFORMBUILDING31. 32. ************* IDF Context for following error/warning message:33. 34. ************* Note -- lines truncated at 300 characters, if necessary...35. 36. ************* 586 BuildingSurface:Detailed,7341.
…