nd this is the error text:
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. [4 of 8] Writing Electric Load Center - Generator specifications ...6. [5 of 8] Writing materials and constructions...7. [6 of 8] Writing schedules...8. [7 of 8] Writing loads and ideal air system...9. [8 of 8] Writing outputs...10. ...... idf file is successfully written to : C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\cell room.idf11. 12. Analysis is running!...13. C:\Users\Pier\Desktop\Dottorato\Energy_plus_file\cell room\EnergyPlus\eplusout.csv14. ......
Done! Read below for errors and warnings:
15.
Thanks in advance to all for your help me
Francesco…
4 to 9
Is there a way to do this with the list or sequence components other than retrieving individual list items and then lofting between each list item (circle). There must be a more elegant way to do this.
Thanks very much.
please see the attached definition as a sample...…
ements between mid axes of elements ( being perpendicular to both). On the attached image, the links are the small elements connectiong nodes 4 to 5, 6 to 7 and 8 to 9. All nodes (1 to 9 including 1', 2', 3') are defined in Karamba as fixed supports but nodes 1,1', 2, 2', 3, and 3' have hinges added with the beam joint component. The freed rotations are shown on the figure.
I wondered if that was the correct way of defining such a structure in Karamba bearing in mind that nodes 1', 2' and3' are free nodes in the reality.
Thanks again for your help !
Yousef…
Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. unsupported operand type(s) for +: 'str' and 'list'6. Failed to write Pelle_aperture000 to idf file7. unsupported operand type(s) for +: 'str' and 'list'8. Failed to write Pelle_aperture001 to idf file9. unsupported operand type(s) for +: 'str' and 'list'10. Failed to write Pelle_aperture002 to idf file11. [4 of 8] Writing Electric Load Center - Generator specifications ...12. [5 of 8] Writing materials and constructions...13. [6 of 8] Writing schedules...14. [7 of 8] Writing loads and ideal air system...15. [8 of 8] Writing outputs...16. ...... idf file is successfully written to : C:\Users\Personal\Desktop\TESI\x001\THOR\EnergyPlus\THOR.idf17. 18. Set runEnergyPlus to True!
or this
0. Current document units is in Meters1. Conversion to Meters will be applied = 1.0002. [1 of 8] Writing simulation parameters...3. [2 of 8] No context surfaces...4. [3 of 8] Writing geometry...5. Runtime error (MissingMemberException): 'hb_EPFenSurface' object has no attribute 'blindsMaterial'6. Traceback:line 1567, in main, "<string>"line 2134, in script
i think that i've same problem with my windows...any suggestion???
Thanks for all…
etc.
Group 2 - 1, 6, 11, 16, 21 etc.
Group 3 - 2, 7, 12, 17, 22 etc.
Group 4 - 3, 8, 13, 18, 23 etc.
Group 5 - 4, 9, 14, 19, 24 etc. "
except in data, the branches start at 0, so 'group 1' is branch 0
as for the order of your points, that depends on the input prior sorting...
yrs …